6
Rev
10/2018
Operating, Installation, and Maintenance
Model THD Specifications
Standard
Optional
Size
Suction x Discharge
ANSI Compatible
Flange
TH-25-150 – 1¼” x 1”
TH-25-200 – 1½” x 1”
TH-32 – 2” x 1¼”
TH-40 – 2½” x 1½”
TH-50 – 3” x 2”
TH-65 – 4” x 2½”
TH-80 – 5” x 3”
TH-100 – 5” x 4”
TH-125 – 6” x 5”
TH-150 – 8” x 6”
Consult factory for
threaded connections
Range of HP
Closed Coupled
Frame Mounted
1 HP to 60 HP
1 HP to 300 HP
Range of Performance
Capacity
Head
8 to 3,000
5 to 710 ft.
Liquid Handled
Type of Liquid
Temperature
Max. Working Pressure
Clean Water
221°F (105°C)
232 PSI (16 Bar)
Materials
Casing
Impeller
Shaft Sleeve
Bracket
Cast Iron
Cast Iron
304SS
Cast Iron
Consult factory for
optional materials
Shaft Seal
Seal Material
Mechanical Seal – Type 21
Carbon/Ceramic/Buna
Carbon/Ceramic/Viton
Carbon/Ceramic/EPDM
Silicon/Silicon/Viton
Direction of Rotation
Clockwise when viewed from motor
Motor
Type
Speed
Bearing
Single Phase
Three Phase
NEMA JP Frame
60 Hz, 1750 and 3500 RPM
2 Pole and 4 Pole
Ball Bearing
TEFC –
Consult Factory
ODP -
Consult Factory
TEFC - 1 HP to 60 HP
ODP -
Consult Factory