Warnings

 

   

 

Warnings in this manual provide information needed for safe operation of the pump, and instructions for 

preventing danger or injury to you or other people.    So that you will know the degree and imminence of 

danger that warnings signify, they are divided into two grades, WARNING and CAUTION, according to the 

seriousness  of  what  will  happen  if  their  instructions  are  not  heeded.  Both  grades  of  warning  contain 

important safety information; carry out all the instructions that they give, without fail. 

 

Warning grade 

Meaning 

Warning

 

Potentially hazardous situation. Failure to follow the instructions could result 

in death or serious injury. 

Caution

 

Failure to follow the instructions given could result in minor injury or damage 

to the pump. 

 
 

Note

 

Used to emphasize important information. 

 

 
 
 

Safety Cautions

 

 

 

 

Warning

 

Turn OFF the power switch when to stop long-term the pump. 

It 

may cause electric shock or electrical leakage and fire.

 

 

Turn  OFF  the  power  switch  before  inspecting  or  repairing  the 
pump.    Not  doing  so  could  result  in  the  pump  starting  up 
suddenly in auto operation, exposing personnel to danger. 

 

Do  NOT  operate  the  pump  for  more  than  1  minute  with  the 
discharge  valve  closed.    Doing  so  will  increase  the  inner 
pressure of the pump, damaging the casing or plugs. 

 

Install  and  ground  an  earth  cable.  Electric  shock  could  occur 
during accidents or electric leakage. 

 

Perform  wiring  work  correctly  as  specified  by  electrical  facility 
technical  standards  and  extension  codes.  Incorrect  wiring  could 
result in electric shock and fires. 

 

Turn OFF the power switch when a power failure. 
Otherwise,  the  pump  may  start-up  suddenly  when  the  power 
supply is resumed, exposing personnel to danger.

 

 

Meanings of symbols accompanying WARNINGs and CAUTIONs. 

C

 

Indicates prohibition (that something must NOT be done). 

Precisely  what  must  not  be  done  is  indicated  by  pictures  or  words  either  inside  the 

circle of the symbol or close to it. 

 

Indicates an imperative (that something MUST be done). 

Precisely what must be done is indicated by pictures or words close to the symbol. 

 

Содержание GS

Страница 1: ...tion 11 3 Accessories 24 5 Electrical maintenance 12 10 Disassembly and Assembly 25 6 Operation 12 1 Disassembly 25 1 Preparation for operation 12 2 Assembly 31 2 Operation Stopping 13 CAUTION Thank y...

Страница 2: ...and fire Turn OFF the power switch before inspecting or repairing the pump Not doing so could result in the pump starting up suddenly in auto operation exposing personnel to danger Do NOT operate the...

Страница 3: ...l be injury danger In addition it may lead to pipe damage danger due to pump vibration Install the coupling guard after the couplings are aligned In addition during pump operation don t be close to th...

Страница 4: ...ironment deteriorated insulation in the electric motor drive or control panel may lead to electric leakage electric shock and fire When the pump is out of use for prolonged periods such as the wintert...

Страница 5: ...and Operation item Otherwise It may cause unsmooth pump operation motor burning or idle operation Avoid the pump operation without priming and permitting air to enter the handled liquid Otherwise the...

Страница 6: ...that the pump is as ordered by referring to the nameplate Fig 1 2 Confirm that no damage has occurred during transportation Check all nuts and bolts to confirm that they are not loose 3 Confirm that a...

Страница 7: ...ons are on Table 1 Table 1 Standard specifications G S G SD Tem perature D ensi ty V i scosi ty I m pel l er ShaftSeal M echani calSeal G l and P acki ng M echani calSeal B eari ng Shi el d B al lB ea...

Страница 8: ...inspection 2 Provide an enclosure around the pump or take some other effective measures to prevent unauthorized personnel from coming near it 3 Install the pump in a location where it is near a water...

Страница 9: ...ts of the installation where it is impossible to avoid the formation of air bubbles However they must not be fitted at points where the pressure is less than atmospheric pressure since the valve would...

Страница 10: ...tling and overhauls Install the suction pipe with an upward gradient towards the pump to avoid the formation of air bubbles 3 Alignment If a simple elastic coupling is used adjust by placing tapered l...

Страница 11: ...cable gland so as to ensure the degree of protection indicated on the nameplate Avoid any mechanical stress being transferred to the motor terminals Comply with the current and frequency limits indic...

Страница 12: ...s surfaces will be hot and you could get burned if you touch them Do not cover the motor with a blanket or cloth Doing so could over heat the motor setting a fire 1 Preparation for operation Note Aft...

Страница 13: ...ischarge valve to start cycle operation 4 Check for abnormal pressure current vibration or noise Keep the cocks of the pressure gauge and compound gauge closed except when taking measurements These ga...

Страница 14: ...eakage value is moderate according to Table 2 d Checking table of the water leakage value as a standard Table 2 The water leakage value as a standard Inner diameter of gland packing mm Initial operati...

Страница 15: ...OFF before inspecting or repairing the pump Not doing so could result in the pump starting up suddenly in auto operation exposing personnel to danger Caution If the pumped liquid is hot water keep yo...

Страница 16: ...ctor It may cause bolts to be lost 5 For gland packing specification make sure the water leakage value is moderate according to Table 2 and preventing over tightening and uneven tightening gland packi...

Страница 17: ...ide the pump could freeze causing damage to the pump Accordingly in such situations provide thermal insulation to prevent the water from freezing 4 When the pump is out of use for three months or more...

Страница 18: ...0 315 125 200 100 250 65 315 150 200 125 250 80 315 100 315 100 250L 80 315L 80 400 125 250L 100 315L 100 400 150 250 125 315 125 400 150 315 150 400 150 400L 125 500 200 400 150 500 200 500 M echani...

Страница 19: ...mechanical seal The pump has no flow rate The pump does not turn The delivery valve is closed or half closed The suction head is too high for the pump Check that the impeller is free Open the valve C...

Страница 20: ...time with the valve closed or half closed Replace the bearings Avoid such a situation Open the valve or stop the pump Excessive operating vibration and noise Fault in installation Bearings damaged Fl...

Страница 21: ...Star Delta commutation Check the power supply Correct the power surges Align and or replace the bearing Remove foreign bodies Connect the pump correctly Correct the cabling Motor overheating Appearanc...

Страница 22: ...t Wait until the temperature goes down Check the temperature before touching Stop the pump and proceed very carefully Stop the pump and proceed very carefully Always fit protection guards Keep your di...

Страница 23: ...orm AB 1 17 Gasket 1 33 Casing Ring 2 2 Shaft 1 18 Shaft Sleev e 1 34 Spring Pin 2 3 Key form AA 1 19 Nut 2 35 Casing 1 4 Deflector 2 20 Gland Bolt 2 36 Handhole Gasket 1 5 Bolt 4 21 Gland 1 37 Handho...

Страница 24: ...fuso Allen S et screw 2 19 S elo Mec nico Mechanical S eal 1 4 Bucha da Bomba P ump bushing 1 20 Anel Distanciador do R otor S pacer R ing 1 5 E ixo S haft 1 21 Anel O R ing O R ing 1 6 P orca sextava...

Страница 25: ...le hazardous and toxic fluids Identify the contents of the pump and observe proper decontamination procedures to eliminate the possible exposure to any hazardous or toxic fluids Wear the proper person...

Страница 26: ...32 for impeller from the Shaft 2 STEP 7 Remove the Impeller 29 from the Shaft 2 through the key STEP 8 Remove the Key 3 of impeller side from the Shaft 2 Refer to the following STEP 9 to 13 for Gland...

Страница 27: ...2 STEP 12 Remove the Gland 21 the Gland Bolts 20 and the Nuts Then remove the Gland Packings 22 and the Lantern Ring 23 from the Casing Cover 27 STEP 13 Remove 2 Plugs 26 from Casing Cover 27 Proceed...

Страница 28: ...17 next STEP 17 Remove Deflectors 4 from Bearing Cover 6 and Bearing Casing 11 STEP 18 Remove the Bearing Cover 6 from the Bearing Casing 11 STEP 19 Remove the Shaft 2 from the Bearing Casing 11 STEP...

Страница 29: ...er to 1 Disassembly Model GS From STEP 4 to STEP 8 and STEP 14 STEP 4 Remove Casing Cover 18 from Bracket 12 STEP 5 Remove Mechanical Seal 19 from Casing Cover 18 STEP 6 Remove Bracket 12 from Motor 1...

Страница 30: ...ve Pump Bushing 4 from Shaft 5 STEP 11 Remove Key 11 from Shaft 5 STEP 12 Remove Stud Bolt 8 from Motor Bushing 2 STEP 13 Remove Set Screw 3 from Motor Bushing 2 STEP 14 Heat the Motor Bushing 2 with...

Страница 31: ...34 to the Casing Cover 27 and Casing 35 STEP 2 Assemble the Plugs 39 40 to Casing 35 STEP 3 Assemble 2 Bearings 7 to the Shaft 2 First install 1 bearing into the shaft from one side Then insert anoth...

Страница 32: ...and the Lantern Ring 23 into the Casing Cover 27 Then assemble the Gland 21 the Gland Bolts 20 and the Nuts 19 by hand to fix the above mentioned parts STEP 9 Insert the Gasket 17 and Shaft Sleeve 18...

Страница 33: ...to Casing Cover 27 STEP 13 Assemble the Casing Cover 27 to the Bearing Casing 11 STEP 14 Assemble the Mechanical Seal to the Shaft 2 Proceed to STEP 15 next STEP 15 Assemble the Key 3 of impeller sid...

Страница 34: ...or impeller to the Shaft 2 STEP 18 Assemble the O Ring 28 to the Casing Cover 27 To prevent the O ring from dropping out Vaseline can be applied to the O ring STEP 19 Assemble the Casing Cover 27 to C...

Страница 35: ...0 C Assemble the Motor Bushing 2 to motor shaft 1 STEP 3 After cooling assemble set screw 3 to motor bushing 2 STEP 4 Assemble stud bolt 8 to motor bushing 2 STEP 5 Assemble key 11 to motor side of sh...

Страница 36: ...of flange of nut 6 in order to assemble set screw 7 STEP 9 Assemble set screw 7 to nut 6 pump bushing 4 STEP 10 Assemble pump bushing 4 to motor bushing 2 STEP 11 Assemble bracket 12 to motor 1 STEP...

Страница 37: ...37 STEP 14 Refer to 2 Assembly Model GS From STEP 14 to STEP 19 STEP 15 Assemble protector 15 to bracket 12...

Страница 38: ...t us Ebara Bombas Am rica do Sul Ltda Filial Vargem Grande do Sul F brica Avenida Manoel Gomes Casaca 840 Parque Industrial PO Box 72 CEP 13880 000 Vargem Grande do Sul S o Paulo Brasil Telefone 55 19...