Installation

 

 
 

3.   Centering 

 

Though the pump and driver have been centered in 
the factory, the common bed may be distorted when 
the foundation bolts are inserted during installation. 
Adjust by placing tapered liners underneath the 
bed, and center so that the shaft coupling is within 
the range indicated in fig. 2. 

 

To center a pump that has been purchased without 
a driver and which is to be directly driven, insert 
liners under the drive, and center so that the shaft 
coupling is within the range indicated in Fig2.  

 
 
 
 
 
 
 
 
 

 
 

 

 

CAUTION

 

 

The coupling guard must be removed to make centering adjustment. Be sure to replace before beginning 
operation. 

 

 

 

 

CAUTION

 

 

Measure the insulation resistance. The value should be more than 1 mega ohm. While making  

 

The measurement, keep the power supply cable off the ground. 

 

 

 

  

CAUTION 

 

Before installation check rotation. Correct rotation is clockwise when viewed from motor side.  

 Read 

ELECTRICAL 

WIRING. 

 

 

 
4. Electrical Wiring.

 

 

 

 

 

 

 
(1)   Refer to 

Fig. 3

 for correct wiring It is important that 

wiring be correct and that motor is properly 
grounded. 

(2) 

 Check the following points before turning on 

operation switch : 
1   Is the fuse the right type ? 

Is the wiring correct ? 

3   Has motor been grounded ? 

4  With a three-phase motor check for a loose or 

completely detached connection Operating on 
only two terminals will result in phase omission, 
causing motor burn out. 

(3) Terminal voltage in motors bearing the EBARA 

nameplate may be within 

±

 10%

 

of the rated 

voltage exceeding this range will lead to breakdown 

(4)  Overloading the motor beyond the prescribed limit 

will reduce its efficiency, is not economical and will 
eventually lead to motor malfunction. 

 

We recommend that a protective motor relay be in- 
stalled to prevent burnout caused by overloading. 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Less than 
0.05 mm 

A-B measurements 
 0.1 mm of each other 

Gap between 
coupling is set 
at 2 ~ 4 mm. 

Fig.2 

WARNING

 

Check that the power is locked off and disconnected before working on pump. 

       All electric work should be performed by a qualified electrician and all notional 

and local electrical codes must be observed.

Содержание FSA

Страница 1: ...Volute Pump MODEL RQWHQWV 1 Safety Information and Introduction 1 2 Installation 2 3 Operation 4 4 Maintenance and Service 5 5 Replaceable Parts 6 6 Troubleshooting 7 7 Contruction 8 8 Disassembly an...

Страница 2: ...16 3 kgf cm2 for standard flange JIS 16K RF Synchronous Speed 3000 min 1 1500 min 1 Installation Indoors Outdoors Impeller Enclosed Shaft seal Mechanical seal Gland Packing Sealing Self flushing Exte...

Страница 3: ...ad of expelling it 4 To reduce effect of water hammer install such a device as a quick closing check valve 5 Suction system 1 The end of the suction piping should be submerged to a depth of at least t...

Страница 4: ...Wiring 1 Refer to Fig 3 for correct wiring It is important that wiring be correct and that motor is properly grounded 2 Check the following points before turning on operation switch 1 Is the fuse the...

Страница 5: ...ing 2 Operation CAUTION Check rotation Correct rotation is clockwise when viewed from top of motor Pump should be started with gate valve closed then the operator should open the valve gradually 1 Clo...

Страница 6: ...bration may be due to conditions such as 15 incorrect centering defective piping or loose foundation bolts Inspect carefully In the event that special vibration control measures are necessary EBARA ha...

Страница 7: ...5 FSKA FH 35 Gs 335 51x35x8 4 6307 ZZ 100x65 FSKA EA 262 40 Gs 335 56x40x8 4 6208 ZZ 100x80 FSGA FH 25 Gs 275 41x25x8 6305 ZZ 100x80 FSHA Gs 225 100x80 FSJA FH 35 Gs 275 100x80 FSGCA Gs 185 100x80 FSH...

Страница 8: ...ion 3 Air pocket in suction piping 4 Suction height too high for pump 1 Prime sufficiently 2 Inspect repair suction piping shaft sealing 3 Reinstall piping 4 Re examine original plan Overloads over cu...

Страница 9: ...oil Spring 111 1 Spring Holder Stainless Steel 1 No Part Name Material Qty 119 Gland Packing 4 or 5 091 Gland 085 Lantern Ring Bushing Bronze 1 No Part Name Material Qty 207 Plug Steel 111 Mechanical...

Страница 10: ...rame and the deflector from the main shaft Mechanical seal type At this point in disassembly the fixed portion of the mechanical seal is attached to the casing cover and the rotating portion to the ma...

Страница 11: ...10 MEMO...

Отзывы: