5.2. PROTECTION AND SIGNIFICANT CAUTION
All live wires or parts are electrically isolated
from the earth. However, there is an additional
safety feature, which composes of all accessible
conducting parts being connected to an earth wire
so that these parts cannot become hazardous
if the main isolating system fails.
5.3. RESIDUAL RISKS
A residual risk of entering into contact (even if
not accidentally) with the rotor in the suction
port exists due to pump construction.
The residual risk exists in models with thermal
motor protection, that once the trip has activated,
the pump may restart without notice once
the motor has cooled to within the required
operating temperature limits.
6. DESCRIPTION AND USE
OF MOTOR-DRIVEN PUMP
6.1. DESCRIPTION
Name
SUBMERSIBLE MOTOR-DRIVEN
PUMPS
Model
(see Nameplate)
DML-DMLV
DL-DL/WC
DS
DVS
6.2. USE FOR WHICH PUMPS ARE DESIGNED
Motor-driven pumps are designed to:
-
Movement of water as described in paragraph 7.1
-
Movement of dirty or sewage water with solids in
suspension as described in paragraph 7.1;
-
Emptying cesspits, sceptic tanks, trenches, etc.
6.3. USE FOR WHICH PUMPS ARE NOT DESIGNED
Motor-driven pumps are not designed to:
-
pump liquids other than water;
-
pump water containing acids or alkalis, and corrosive
liquids in general;
-
pump seawater;
-
pump flammable liquids and hazardous liquids in
general;
-
enter into contact with food products;
-
be used in structures designed for living organisms
(pools, aquariums, fish farms, etc.);
-
be used in significantly important systems (computer
cooling or refrigeration systems, etc.):
-
be used in outdoor environments if equipped with
power cord under 10 m long;
-
be used for purposes other than those described in
Chapter 6.2 “Use for which pumps are designed”.
7. SPECIFICATIONS
The manufacturer reserves the right to modify technical
specifications to improve or update its products without
prior notice.
7.1. SERIES-D PUMP TECHNICAL SPECIFICATIONS
WARNING!
The motor-driven pumps must never be made
to work without liquid.
DL, DL W/C
Delivery
Diameter/model
Max solid
dimension
[mm]
Max fibre
length
[mm]
Max
Submersion
depth [m]
Ø 65
Ø 80, Ø 100(80)
Ø 100
Ø 150 (up 22 kW)
Ø 200 (up 22 kW)
Ø 250 (up 22 kW)
Ø 300 (up 22 kW)
all > 22kW
Ø 35
Ø 50
Ø 60
Ø 70
Ø 76
Ø 82
Ø 90
Ø 76
195
240
300
400
500
550
600
500
7
DVS
Delivery
Diameter/model
Max solid
dimension
[mm]
Max fibre
length
[mm]
Max
Submersion
depth [m]
50DVS5.75, 51.5
65(80)DVS5.75, 51.5
65(80)DVS52.2, 53.7
Ø 21
Ø 33
Ø 41
100
200
245
3
3
7
DS
Delivery
Diameter/model
Max solid
dimension
[mm]
Max fibre
length
[mm]
Max
Submersion
depth [m]
Ø 50
Ø 65
Ø 80
Ø 100
Ø 5
Ø 6
Ø 7
Ø 8
50
3 (
≤
1.5 kW)
7 (>1.5 kW)
DML/DMLV
Delivery
Diameter/model
Max solid
dimension
[mm]
Max fibre
length
[mm]
Max
Submersion
depth [m]
DML
DMLV Ø80
DMLV Ø100
Ø 76
Ø 80
Ø 100
500
400
500
7
EN
PUMPED LIQUID SPECIFICATIONS
PH
5 ÷ 9
Maximum liquid temperature
0 ÷ 40°C
(without float)
Free chloride concentration
≤
10 mg/l
Chloride ion concentration
≤
200 mg/l
Содержание DL
Страница 78: ...78 12 60Hz 50Hz 50Hz 60Hz 9 9 GR...
Страница 84: ...84 12 60Hz 50Hz 50Hz 60Hz 9 9 BG...
Страница 126: ...126 12 60 50 50 60 9 9 RU...
Страница 134: ...134...
Страница 135: ...135...
Страница 136: ...136...
Страница 137: ...137...
Страница 138: ...138 14 1 2 EBARA Pumps Europe S p A 14 1 1 EBARA DENSAN KUNSHAN...
Страница 139: ...139 NOTE...