2. Output Signal
1. Input signal
MP Start
BP Start
Reset
Emergency Stop
Switch [ OPTION ]
Remote / Local
Casing Temp. (TRIP)
MP Run
BP Run
MP Stop
BP Stop
6
+
DC12V
(-)
2 (+)
1
1 kOHM
(+)
Open
collector
Dry
contact
Control
Connector
3
4
8
9
50
+
27
+
26
Inductive
load
12
14
+
Resistance
load
11
+
DC50V
Max. 50mA
DC50V
Max. 50mA
5
(+)
(+)
(+)
[ NOTE ]
1. Insert a diode (100V / 1A class) when
connecting inductive load by output signal.
2. Do not connect wiring to opened pins.
It may cause malfunction.
DC50V
Max. 50mA
DC50V
Max. 50mA
Figure 4.6 Control Signal Wiring