Position the pump on its end with the shaft up. The work surface should be level, capable of supporting the motor.

Make certain the motor is not connected to a power source. Do not install or assemble the pump on a motor 
connected to a power source. Serious injury could occur if the motor activates during pump assembly.

Assembling the Pump – Models 3HP - 15HP 

(see page 7 for sectional view)

1. Position a Nylon gasket (117-3) over the motor shaft.

2. Carefully press the rotating seal assembly onto the shaft sleeve (041). The smooth face of the 

rotating ring must make good contact with the seal seat and the seal retainer must seal against the shaft sleeve.
Note: Seal faces should be wiped clean with non-oil based solvent or alcohol.

3. Using finger pressure only, insert the seal seat into the casing cover (011). Press the seal until it evenly 

bottoms out in the seal cavity.

4. Position the cast iron motor bracket (018) over the shaft. Fasten the bracket to the motor, tightening bolts 

using a cross-tightening pattern. (Tighten the bolts to the factory recommended torque specifications of 8 ft. lbs.)
Overtightening may cause stripping of threads.

5. Carefully position the casing cover (011) and seal over the shaft. Be careful not to damage the stationary 

seal seat.

6. Slide the stainless steel shaft sleeve, with rotating assembly, over the motor shaft.

7. Position the O-ring (115) around the casing cover (011). Do not cut, nick, or damage the O-ring during the 

installation.

8. Install the impeller shaft key (

3

/

16

" x 

3

/

16

" x 1 

3

/

16

").

9. Place the seal spring assembly over the rotating piece of the seal in position to receive the impeller.

10. Place a Nylon gasket (117-2) on top of spring retainer.

11. Firmly press the impeller (021) into position by aligning the slot over the shaft key. Press the impeller down 

the shaft until it bottoms and seats squarely against the Teflon gasket (117-2) and shaft sleeve (041).

12. Place a Nylon gasket (117-1) over the impeller hub and into the impeller eye. Install the impeller bolt (125) to 

secure the impeller to the shaft. Do not overtighten the shaft bolt. (Use a thread compound or cement to 
secure the shaft bolt and prevent it from working loose.)

13. Tighten the impeller bolt. (Tighten the bolts to the factory recommended torque specifications of 11 ft. lbs.)

14. Install the pump volute (001) over the seal plate. Rotate the volute to align with the bolt holes and secure it 

with the bolts, washers, and nuts. Cross-tighten the bolts to the factory recommended torque specifications 
(8 ft. lbs.).

15. With a socket wrench, rotate impeller to check for alignment. If rubbing against casing, loosen bolts on 

casing and retighten.

3U / 3UB Assembly Instructions

WARNING

Содержание 3U

Страница 1: ...End Suction Centrifugal EBARA Fluid Handling EBARA International Corporation Operating Instructions Installation Maintenance Manual M o d e l s 3 U 3 U B...

Страница 2: ......

Страница 3: ...piping system MUST be protected against below freezing temperature Failure to do so could cause severe damage and voids the Warranty 8 Avoid system pressures that may exceed one and a half times the...

Страница 4: ...H THE DISCHARGE VALVE TIGHTLY CLOSED IF THE PUMP RUNS FOR AN EXTENDED PERIOD OF TIME WITHOUT LIQUID BEING DISCHARGED THE LIQUID IN THE PUMP CASE CAN GET EXTREMELY HOT CAUSING SEVERE DAMAGE TO THE PUMP...

Страница 5: ...0 50 20 30 40 50 60 80 100 150 200 300 400 600 700 M 3 MIN CAPACITY IN GPM TOTAL HEAD Three phase motor only 50 160 10HP 40 160 7 HP 32 200 7 HP 32 200 7 HP 32 125 3HP 50 125 7 HP 40 125A 5HP 50 125 1...

Страница 6: ...ressure 230 PSI 15 Bar Materials 3U 3UB Casing 304L Stainless Steel 304L Stainless Steel Impeller closed type 304L Stainless Steel Bronze Stainless steel option for 3UB models Shaft Sleeve 304L Stainl...

Страница 7: ...er 3U Impeller 3UB Key Shaft sleeve Mechanical seal O Ring Gasket Gasket Gasket Impeller Bolt Motor support not shown Plug Motor Suction Flange Gasket Discharge Flange Gasket 304L Stainless 304L Stain...

Страница 8: ...Drain plug O ring Key Impeller nut Flange Gasket Flange Gasket Motor support Casing support 65 160 25HP only Coupling guard Lip seal 304L Stainless Cast iron Cast iron 304L Stainless Steel Stainless...

Страница 9: ...se motors are tri voltage Check the nameplate and follow the proper wiring procedure for the voltage you are using Improperly wiring the motor could result in damage to the motor b Three phase motors...

Страница 10: ...AMINATION OF PUMP PARTS IMPELLER Replace the impeller if any vane is broken excessive erosion shows or if labyrinth surfaces are worn Impeller cap screw washer and lockwasher should be replaced if dam...

Страница 11: ...sition the casing cover 011 and seal over the shaft Be careful not to damage the stationary seal seat 6 Slide the stainless steel shaft sleeve with rotating assembly over the motor shaft 7 Position th...

Страница 12: ...using finger pressure only press the stationary seal into the seal seat Wipe the seal face clean with alcohol and a soft cloth 7 Position the o ring 026 around the casing cover 8 Using hand pressure...

Страница 13: ...ressure switch setting Leakage in system Too high pressure setting TROUBLESHOOTING Check power supply circuit Correct control circuit Remove cause of obstruction Release seal by turning shaft Repair o...