OPERATION 

The operation of the dehumidifier is to remove moisture from the air by having 
it condense on the cold tubes of the evaporator coil. The air then passes over 
the hot condenser coil and returns to the conditioned space slightly warmer 
and dryer than when it entered the dehumidifier unit. 

TEST FOR CORRECT OPERATION 

The following procedures should be followed to test the RM40-SH for correct 
operation.

 

1. After unpacking, examine all external features to confirm damage free

shipment. Report all defects and damage at once.

2. Check dehumidification process:

a)

Place unit on a level  surface. Connect a suitably sized hose to
the condensate outlet and run the hose to a permanent drain.

b)

Start up unit by rotating the adjustable humidistat knob counter
clockwise to the minimum setting. Plug in the unit to a grounded
receptacle  with  a  15  amp  power  source.  Rotate  the  humidistat
knob clockwise to the maximum setting.

c)

Check the compressor is running.

d)

Leave the machine running for 15 minutes.

e)

Observe the evaporator coils, to confirm frost formation.

i. If  the  air  temperature  is  below  70ºF,  an  even  coating  of

frost  should  cover  the  entire  evaporator  coils,  except  for
the last one or two coils.

ii. If the temperature is above 70ºF, frost and/or droplets of

condensed water should cover the entire evaporator coil.

If after carrying out all the above checks, the unit does not appear to function 
correctly refer to the section, “Trouble Shooting”, or contact your supplier. 

WARNING: 

Due  to  the  high  pressures  within  the  refrigeration  circuit,  under  no
circumstances  must  direct  heat  be  applied  to  the  evaporator  coil  in  an
attempt to remove the build up of ice.

No attempt should be made to cut open any part of the refrigeration circuit
due  to  high  pressures  and  gas  involved.  If  the  unit  is  switched  off  at  the
mains power supply for any reason, the unit must be allowed to stand at
rest for at least three minutes before restarting. Failure to do so may cause
the  unit  to  blow  the  fuses  owing  to  the  compressor  due  to  there  being  a
refrigerant imbalance.

Humidistat

 

This humidistat operates to control the on/off function of the dehumidifier unit 
as required. 

E B A C   R M 4 0 S H   O W N E R ' S   M A N U A L 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Содержание RM40-SH

Страница 1: ...Page 1 of 12 Drawing TPC519 Issue 1 Date 03 03 20 RM40 SH INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 800 237 9199...

Страница 2: ...RM40 SH PACKAGE CONTENTS Item Description Quantity 10187SH US Dehumidifier 1 3014338 PVC tube 12mm I D 3 M 3086101 Jubilee clip 1 TPC519 Manual 1 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Na...

Страница 3: ...ected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling ph...

Страница 4: ...ts manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL RM40 SH HEIGH...

Страница 5: ...rve the evaporator coils to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator coils except for the last one or two coils ii If...

Страница 6: ...mperatures above 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low cha...

Страница 7: ...be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant c...

Страница 8: ...cked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center 4 Contact the Factory Service Center Little or no defrost when required 1 Faulty Ti...

Страница 9: ...t Coil Set 2018743 1 3 Capillary 3014254 1 64ft 4 Solenoid valve 3020836 1 5 Filter dryer 3020937 1 6 Solenoid coil 3030451 1 7 Fan Motor 3947012 1 8 Fan Blade 3947014 1 9 Compressor 3944954 1 10 Humi...

Страница 10: ...y sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained...

Страница 11: ...Page 11 of 12 Drawing TPC519 Issue 1 Date 03 03 20 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Systems Inc purennatural com 1 800 237 9199...

Страница 12: ...ate 03 03 20 Distributed by Pure n Natural Systems Inc PO Box 1137 Streamwood IL 60107 purennatural com 1 800 237 9199 FAX 630 540 9717 E B A C R M 4 0 S H O W N E R S M A N U A L Pure n Natural Syste...

Отзывы: