Drawing   : - TPC303 
Issue 

: - 7 

Date 

: - 03/10/12 

KOMPACT 

SPARE PARTS LIST 

N

UMBER

 

D

ESCRIPTION

 

P

ART

N

UMBER

 

Q

UANTITY

 

Filter 

1019712 

Timer 

1600500 

Evaporator Coil 

2026074 

Condenser Coil 

2026014 

Drain Tray 

2131107 

Capillary Tube 

3014251 

48” 

Solenoid Valve 

3020814 

Filter Dryer 

3020901 

Compressor 

3022169 

10 

Solenoid Coil 

3030421 

11 

Capacitor 

3030908 

12 

Terminal Block 

3031460 

13 

Fan Motor & Blade Assembly 

3035753 

14 

Black Rubber Foot 

3101436 

15 

Pump 

3160143 

16 

Mains Lead 

3035148 

E B A C    K O M P A C T    R E S T O R A T I O N    D E H U M I D I F I E R 

Pure n Natural Systems  |  purennatural.com  |  1-800-237-9199

Содержание KOMPACT

Страница 1: ...9 Drawing TPC303 Issue 7 Date 03 10 12 KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL E B A C K O M P A C T R E S T O R A T I O N D E H U M I D I F I E R Pure n Natural Systems purennatural com 1 800...

Страница 2: ...ONTENTS Item Description Quantity 10240KP US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC303 Manual 1 E B A C K O M P A C T R E S T O R A T I O N D E H U M I...

Страница 3: ...asses through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated by the compressor The air is therefore discharged fr...

Страница 4: ...ial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit please refer to the product data label MODEL 10240KP US HEIGHT 24 610mm WIDTH 20 508mm DE...

Страница 5: ...ve 78 F frost and or droplets of condensed water should cover the entire evaporator coil F After continuous running time of approximately 55 minutes unit will enter Hot Gas defrost mode for several mi...

Страница 6: ...rost Partial frosting accompanied by frosting of the thin capillary tubes indicates loss of refrigerant gas or low charge During this inspection check visually to ensure that the pump rollers are turn...

Страница 7: ...and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak causing further loss of refrigerant gas 3 The refrigerant compressor f...

Страница 8: ...3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1...

Страница 9: ...1107 1 6 Capillary Tube 3014251 48 7 Solenoid Valve 3020814 1 8 Filter Dryer 3020901 1 9 Compressor 3022169 1 10 Solenoid Coil 3030421 1 11 Capacitor 3030908 1 12 Terminal Block 3031460 1 13 Fan Motor...