background image

 

 
 
 

CD60 OWNERS MANUAL 

                                                                             Page 8 of 9 

Drawing No.  :-  TPC249 
Issue :- 

Date :- 

12/06/03

 
 

CD 60 

SPARE PARTS LIST

 

 

 

 

N

UMBER

 

D

ESCRIPTION

 

P

ART 

N

UMBER

 

Q

UANTITY

 

1 Compressor 

 

(RGA5467EXA) 3022169  1 

Compressor Overheat Protector 

N/A     

3 Compressor 

Capacitor 

3030908  1 

4 Condenser 

Coil 

2026014  1 

5 Evaporator 

Coil 

2026013  1 

6 Filter 

Dryer 

3020901  1 

Fan Motor Assembly 

3035753 

8 By-pass 

Valve 

3020814  1 

9 Mechanical 

Timer 

3030781  1 

10 Hour 

Meter 

3030779  1 

11 Rocker 

Switch 

3035914  1 

12 Terminal 

Block 

3031460  1 

13 Solenoid 

Coil 

3030421  1 

14 Contactor 

3036157  1 

15 Power 

Cord 

3035148  27ft 

16 Drain 

Tray 

2131107  1 

17 Drain 

tube 

P-clip 

3035697  1 

18 

Drain Tubing    

3014336 

25ft 

19 Trolley 

(optional) 

1026004  1 

20 Wheel 

3050110  2 

21 1” 

Starlock 

Washer 

3082601  4 

22 Condensate 

Pump 

3160129  1 

23 Purge 

Switch 

3036779  1 

24 Quick 

Disconnect 

3086144  1 

25 

Snap Hose Clip 

3086135 

26 

Hose Clip Snapper 

3086136 

 

 

 

 

 

Содержание CD60

Страница 1: ...CD60 OWNERS MANUAL Page 1 of 9 Drawing No TPC249 Issue 2 Date 12 06 03 EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...ensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the addi...

Страница 3: ...Drawing No TPC249 Issue 2 Date 12 06 03 SPECIFICATIONS MODEL CD60 HEIGHT 17 WIDTH 20 DEPTH 14 WEIGHT 80 lbs AIRFLOW 360 CFM POWER SUPPLY 115V 60Hz 1 ph FINISH Powder coated Epoxy OPERATING RANGE 33 F...

Страница 4: ...nning for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should cover the entire evap...

Страница 5: ...the refrigerant charge run the unit for 15 minutes and briefly remove the top cover The evaporator coil should be evenly frost coated across its surface At temperatures above 80 F the coil may be cov...

Страница 6: ...e side of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may le...

Страница 7: ...Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 C...

Страница 8: ...embly 3035753 1 8 By pass Valve 3020814 1 9 Mechanical Timer 3030781 1 10 Hour Meter 3030779 1 11 Rocker Switch 3035914 1 12 Terminal Block 3031460 1 13 Solenoid Coil 3030421 1 14 Contactor 3036157 1...

Страница 9: ...CH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS...

Отзывы: