background image

 
 
 

WM80 OWNERS MANUAL 

                                                                       Page 5 of 10 

Drawing No.  :-  TPC313 
Issue :- 

Date :- 

08/05/07

INSTALLATION 

 

The WM80 Dehumidifier can be left free standing unit, alternatively can be wall 
mounted for instructions on mounting the unit please read the following: 
 
A full installation kit is included in the package to allow a problem free install. This kit 
comprises of the following :- 
 
1 X WM80 Dehumidifier 
1 X Mounting Bracket 
4 X Rawl plugs and screws 
4 X M6 Hex Head Bolts, flat and spring washers 
 
For mounting the WM80 Dehumidifier to a wall you will first need to remove the 
cover from the unit and detach the wall mounting bracket from the rear of the unit by 
removing the 4 bolts that secures it. 
 
With reference to the installation drawing at the rear of this manual, maintain the 
minimum clearances from adjacent objects (ie walls celings etc). Maintaining these 
distances will ensure easy access for installation and maintaining the unit during the 
products life 
 
Place the wall mounting bracket onto the wall, ensuring the correct orientation, and 
the bracket is level. Mark off 4 points on the wall where you will be securing the 
bracket, the bracket has numerous holes and slots to allow the bracket to be 
mounted at different points depending on the wall you are mounting it to. It is 
advised to have the fixing points spaced out as far as possible to allow a more 
ridged and secure installation. 
 
Using a 7mm masonry bit, drill the 4 points you marked off earlier to a depth of 
40mm, insert the 4 Rawl plugs into the wall that are supplied with this unit.  
 
Secure the wall mounting bracket to the wall using the 4 brass screws supplied with 
the unit. 
 
Ensure all fixings are tight and bracket is secured to the wall. 
 
Screw 2 X M6 Bolts into the top fixings on the bracket, only screwing them in a 2-3 
turns. Lift the unit onto the bracket and hook the unit onto the bolts using the keyhole 
slots in the rear of the unit do not tighten the bolts yet. Fit the 2 remaining bolts 
through bottom holes in the rear of unit and into the wall mounting bracket and 
tighten all 4 bolts. 
 
Check to make sure the unit is secure to the wall mounting bracket. 
 
Replace cover and refit all fixings that have been removed.   

Содержание 10284GL-US

Страница 1: ...WM80 OWNERS MANUAL Page 1 of 10 Drawing No TPC313 Issue 1 Date 08 05 07 EBAC MODEL WM80 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Страница 2: ...s dew point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanent drain The cooled air then passes through the hot condenser coil where it is...

Страница 3: ...ing No TPC313 Issue 1 Date 08 05 07 SPECIFICATIONS MODEL 10284GL US HEIGHT 19 2 WIDTH 21 9 DEPTH 11 4 WEIGHT 81 lbs AIRFLOW 360 CFM POWER SUPPLY 115V 60Hz 1 ph FINISH Powder coated Epoxy OPERATING RAN...

Страница 4: ...st formation f If the air temperature is below 25 C an even coating of frost should cover the entire evaporator coil g If the air temperature is above 25 C frost and or droplets of condensed water sho...

Страница 5: ...ensuring the correct orientation and the bracket is level Mark off 4 points on the wall where you will be securing the bracket the bracket has numerous holes and slots to allow the bracket to be moun...

Страница 6: ...The evaporator coil should be evenly frost coated across its surface At temperatures above 25 C the coil may be covered with droplets of water rather than frost Partial frosting accompanied by frostin...

Страница 7: ...e side of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may le...

Страница 8: ...lt 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve...

Страница 9: ...er 2028420 1 2 Timer 1600500 1 3 Evaporator Coil 2026074 1 4 Condenser Coil 2026014 1 5 Drain Tray 2131107 1 6 Capillary Tube 3014251 48 7 Solenoid Valve 3020814 1 8 Filter Dryer 3020901 1 9 Compresso...

Страница 10: ...ACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS...

Отзывы: