- 38 -
EBA 721-06 LT
A
B
B
A
2000
1750
1500
1250
1000
750
500
250
7
8
9
4
5
6
1
0
M
P S F1
F2
F3
I
D
CP AM E
C
Stop
PROGRAMM
STEP
M
E
S
Start
2
3
•
Possible malfuntions
•
The machine does not funktion after being
moved to another position.
If the machine still does not function then the
rotation must be reversed.
The machine is wired according to the IEC
standards. We recommend that alterations to
the rotary direction be made in the socket. It is
also possible to make alterations in the plug by
exchanging "L1" and "L2".
Danger!
Incorrect exchanging of the connections
will endanger the operator.
This work must be carried out by an
electrician.
Cut cannot be activated.
•
Safety light beam is interrupted /dirty.
Remove all items obstructing the safety area
(
A
) and clean the glass from the sender (
B
)
and receiver (
B
).
•
Measurement has not been reached
correctly.
LED "S"
N
does not turn off.
Push the
S
button again.
•
Measurement below 9 cm.
The false clamp plate must not be mounted.
Remove the false clamp plate and store it in
the
provided holder
(see page 16).