background image

Introduction and Overview

2.1 Connections

UXA4401 signal input and output connections are accomplished 
via RCA Phono and Euroblock style connectors. A GPIO (General 
Purpose In/Out) Euroblock connector enables some amplifier 
functions to be controlled, and wireless or RJ45 socket Ethernet 
network connection options are also provided.  

UXA4401amplifiers have no mains power switch and are 
operational as soon as mains power is connected via the IEC 
60320 mains socket.

2.2 Network Features

UXA4401 amplifiers are TCP/IP network connected devices that 
require a wired or wireless network connection to access their 
configuration menus. The configuration menus are accessed via 
the UXA4401 Control web app interface and cover Input, Zone, 
Output and General Settings functions. The configuration menus 
are fully described in Section 4 of this manual.

2.3 Dimensions

UXA4401 amplifier dimensions and features are illustrated in 
Diagrams 1a and 1b. The amplifiers are primarily intended for 
installation in an equipment rack but can also be under-desk 
or wall mounted, or used free standing. They are fan-cooled 
and must be installed such that ventilation apertures are not 
obstructed.

2.4 Firmware

This manual describes the features, functions and user interface of 
UXA4401 amplifiers running Firmware Version 1.2.0. 

It is strongly recommended that the firmware version installed in 
the amplifier in use is checked initially, and regularly thereafter. 

If updated firmware is available, the amplifier should be 
updated as a priority.

The firmware installed in the amplifier can be identified 

and updated  by selecting the Device option in the Control web 
app Settings Menu. Firmware versions can be checked, and 
firmware downloaded, from the EAW website:

3. Carton Contents

UXA4401 amplifiers are shipped in a cardboard carton containing 
the amplifier unit, a mains cable appropriate for the sales territory, 
an accessory pack, and a document pack. The full contents is listed 
below.

• Amplifier unit 
• Mains power cable 
• Input connector x 2 
• GPIO socket connector 
• Output connector x 1 or 2 
• Adhesive rubber feet x 4 
• Document pack

Содержание UXA4401

Страница 1: ...UXA4401 User Manual...

Страница 2: ...particularly at plugs convenience receptacles and the point where they exit from the apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specifi...

Страница 3: ...4 Installation 5 Configuration 6 Connections 7 Operation 8 Specifications 2 Amplifier Overview UXA4401 amplifiers are half rack width 1U format power amplifiers that can drive both conventional low i...

Страница 4: ...ers are primarily intended for installation in an equipment rack but can also be under desk or wall mounted or used free standing They are fan cooled and must be installed such that ventilation apertu...

Страница 5: ...Overview Diagram 1A UXA4401 four channel amplifier dimensions Shaded area defines ventilation space 44 mm 1 7 in 220 mm 8 7 in 80 mm 3 1 in 319 mm 12 6 in 25 mm 1 0 in...

Страница 6: ...ifier at all times Ventilation apertures are also located on the rear panel of the amplifier and must not be obstructed It is important to retain at least 80 mm 3 1 in free space for airflow behind th...

Страница 7: ...using connecting plate hardware The adhesive rubber feet should also be used in these circumstances to minimise the possibility of vibration between the amplifier and mounting surface Wall and desk mo...

Страница 8: ...LAN IP address is 192 168 64 100 Configure the laptop or desktop computer for a fixed IP address in the same IP range eg 192 168 64 10 with Subnet mask of 255 255 255 0 or prefix 24 and set the Gatewa...

Страница 9: ...wn Note When adjusting input gain the input level display should remain green If it displays red the input gain should be reduced 5 3 Configuration Menus Opening a web browser that is network connecte...

Страница 10: ...signed to zones The GPIO Volume Control Diagram 4d option enables external volume control to be applied to individual zones The GPIO configuration menu can be found under the Settings Tab The Compress...

Страница 11: ...401 amplifier model and the input zone and output mode configuration The Routing menu Diagram 4f enables zones to be assigned to amplifier outputs Note Routing for zones specified as stereo will autom...

Страница 12: ...ion and management is described in Section 5 3 5 2 Select the appropriate zcp format speaker preset data file to import from either a Library or a computer folder The preset data will be applied to th...

Страница 13: ...well as adjusting global gain Diagram 4l Diagram 4l Preset Crossover Gain The Speaker EQ in the preset menu allows for configuring customized parametric EQ on the output level Diagram 4m Diagram 4m Pr...

Страница 14: ...audible increase the frequency setting one step at a time until the distortion is no longer audible Driver Alignment in the preset menu will allow for delay to be set between driver passbands Diagram...

Страница 15: ...nder the Device menu The Backup Restore menu enables amplifier configuration data to be downloaded to an external archive and enables previously saved configuration files to be uploaded and adopted by...

Страница 16: ...m Gain Trim Gain Trim Input Sensitivity Input Gain Input Gain Input Selection Input Setup Zone Setup Routing Output Setup Output 1 Output 2 Output 3 Output 4 Zone Adjustment Parameters Speaker Preset...

Страница 17: ...he zone to be configured The number of zones available and their channel format stereo or mono will depend on the amplifier model input setup and output mode Lo Z or Hi Z For example a two output ampl...

Страница 18: ...n 8 has a low output impedance and is able to supply a maximum current of 10mA Note GPIO Pin 1 and Pin 3 both offer ground connections Pin 1 is connected directly to the amplifier chassis Pin 3 is con...

Страница 19: ...Note Two output amplifier model connection sockets differ only in the deletion of channel 3 and channel 4 output connectors Digital Inputs UXA4401 amplifier S PDIF stereo digital audio input connectio...

Страница 20: ...ifiers to a TCP IP network is described in Section 5 of this manual Cable Gauge Table Lo Z installations 0 5dB attenuation 4 8 loads Cable Gauge Table 70V Hi Z installations 1 0dB attenuation 20 speak...

Страница 21: ...e exclamation point printed next to the output terminals of the amplifiers is in addition to the CLASS 2 WIRING text intended to alert users to the risk of hazardous voltages Output connectors that co...

Страница 22: ...Output Off No output signal present Green Signal present on one or more outputs Amber Signal limiting clipping on one or more outputs Red One or more channel pair is in overload protection mode Networ...

Страница 23: ...vel of performance and in good operating condition Any damage to or unsatisfactory performance from these amplifiers caused by inadequate or failed input or output ancillaries may invalidate support w...

Страница 24: ...2023 Eastern Acoustic Works All rights reserved Products are not drawn to scale All terms conditions and specifications subject to change without notice Eastern Acoustic Works One Main Street Whitinsv...

Отзывы: