DX Link Clocking
Description
When multiple DX1208 units are connected via DX Link, their sample clocks must be
synchronized to a common master clock source. One DX1208 must be set as the master
device, and all others must be set to slave devices, regardless of how many units are
connected together.
NOTE: Failure to configure a multi-unit system exactly as described will cause sample
clock conflicts between one or more devices. This in turn will cause no audio
to pass through one or more DX Link connections.
Parameters
•
Master/Slave
Sets whether the device is a clock [Master] or clock [Slave].
DX Link Status
Description
These two LEDs indicate the status of any signal present at the units DX Link Rx (receive)
jack.
Indicators
•
DX Cable Present
Lights when a signal is present at the unit’s DX Link Rx (receive)
jack. If this indicator is lit but the
DX Link Active
indicator is not,
then the signal is either not valid, or the signal is asynchronous
with respect to the unit’s internal sample clock. When this
condition occurs verify that the DX Link
Master/Slave
settings for
all units have been correctly configured (see
DX Link Clocking
),
and that all DX Link cables are properly seated in their jacks.
•
DX Link Active
Lights when the signal present at the unit’s DX Link Rx jack is
synchronous with the transmitting unit and the audio is valid.
Firmware Version
For Device Windows this text fields lists the current embedded firmware version of the
connected DX1208 device. For Design Windows these fields are blank. Consult the release
notes for the version of DX Navigator you are running to verify whether the DX1208 devices in
your system are running compatible firmware. It is particularly important in larger systems with
multiple locations and/or DX Navigator client installations that both software and firmware be
upgraded for the entire system at one time to avoid compatibility issues between DX Navigator
and the installed firmware.