background image

2

 – CXA240

CXA240 – 

3

1. SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in 

accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades with 

one wider than the other. A grounding type plug has two 

blades and a third grounding prong. The wide blade or the 

third prong are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12.  Use only with the cart, stand, tripod, 

bracket, or table specified by the 

manufacturer, or sold with the 

apparatus. When a cart is used, use 

caution when moving the cart/

apparatus combination to avoid injury 

from tip-over.

TABLE OF CONTENTS

1. SAFETY INSTRUCTIONS ...................................................2

2. INTRODUCTION..................................................................3

            KEY FEATURES............................................................3

            APPLICATIONS ...........................................................3

3. FRONT PANEL FEATURES .................................................4

4. REAR PANEL FEATURES....................................................5

5. THERMAL CONSIDERATIONS ..........................................8

6. CONNECTIONS ...................................................................8 

7. TYPICAL HOOKUP DIAGRAM...........................................9

8. SPECIFICATIONS..............................................................10

            BLOCK DIAGRAM.....................................................11

9. SERVICE INFORMATION .................................................11

10. EAW COMMERCIAL WARRANTY ................................11

13.  Unplug this apparatus during lightning storms or when 

unused for long periods of time.

14.  Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid 

has been spilled or objects have fallen into the apparatus, 

the apparatus has been exposed to rain or moisture, does 

not operate normally, or has been dropped.

15.  This apparatus must be connected to a mains socket outlet 

with a protective earthing connection (the third grounding 

prong).

16.  This apparatus has been equipped with an all-pole, rocker-

style AC mains power switch. This switch is located on the 

front panel and should remain readily accessible to the user.

WARNING:

 To reduce the risk of fire or electric shock, do 

not expose this apparatus to rain or moisture.

WARNING:

 The 70 V and 100 V output terminals are 

potentially HAZARDOUS and any external wiring connected 

to these terminals requires installation by an INSTRUCTED 

PERSON or the use of ready-made leads or cords.

WARNING:

 This equipment has been designed to be 

installed by qualified professionals only! There are many 

factors to be considered when installing professional 

sound reinforcement systems, including mechanical and 

electrical considerations, as well as acoustic coverage and 

performance. EAW Commercial strongly recommends that 

this equipment be installed only by a professional sound 

installer or contractor.

Part No. 0010172  Rev. A  05/04
© 2004 LOUD Technologies Inc.  All Rights Reserved.  Printed in China.

CAUTION    

AVIS

RISK OF ELECTRIC 

SHOCK • DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral triangle is 

intended to alert the user to the presence of uninsulated "dangerous voltage" 

within the product's enclosure, that may be of sufficient magnitude to constitute 

a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral est 

utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de "voltage 

dangereux" non isolé d'ampleur suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to alert the user 

of the presence of important operating and maintenance (servicing) instructions 

in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé pour 

alerter les utilisateurs de la présence d'instructions importantes pour le fonction-

nement et l'entretien (service) dans le livret d'instruction accompagnant l'appareil.

Содержание CXA240

Страница 1: ...T TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTION SEE INSTRUCTIONS BEFORE USING WARNING INPUT 6 3A...

Страница 2: ...h This switch is located on the front panel and should remain readily accessible to the user WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture WARNI...

Страница 3: ...z determined by a rear panel voltage select switch and is supplied by a detachable IEC power cord A rear panel terminal strip connection is provided for connecting an external 24 VDC backup battery wi...

Страница 4: ...rn down the volume level so the top two LEDs do not light otherwise the outgoing signal will clip and distort 3 POWER Use this rocker switch to turn the unit on or off This connects disconnects the AC...

Страница 5: ...e DC rail supply to the power amplifier Make sure that the AC supply is turned off before removing the fuse When you are sure that all is safe press in the fuse cover and turn it counter clockwise Rep...

Страница 6: ...ransformer with an input voltage equal to that of the line 70 V or 100 V Make sure that the sum of the power capacities of the speakers does not exceed 90 of the amplifier s rated output power 216 W C...

Страница 7: ...The two inputs are summed to mono Use balanced connections where possible instead of RCA unbalanced connections as these offer better rejection of noise Use high quality three conductor shielded cabl...

Страница 8: ...heatsink Leave at least one rack space above and below and at least 6 inches behind the chassis to allow proper ventilation If the amplifier should overheat a thermal switch turns off the power ampli...

Страница 9: ...CXA240 9 7 TYPICAL HOOKUP DIAGRAM CXA240 AMPLIFIER F U S E F U S E F U S E MIXER OR PREAMPLIFIER EAW DX810 MIXER AMPLIFIER EAW CAM150...

Страница 10: ...5 50 60 Hz 24 VDC battery Power Consumption 486 W Physical Dimensions HxWxD 6 1 in 156 mm x 19 0 in 483 mm x 14 5 in 368 mm Including Feet Weight 34 1 lb 15 5 kg Warranty 5 years parts and labor DISCL...

Страница 11: ...nty LOUD Technologies Inc requires its authorized EAW Commercial distributors to abide by the following warranty terms for all EAW Commercial brand products all dates are from the date of delivery fro...

Страница 12: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2004 LOUD Techno...