background image

10

 – CXA240

CXA240 – 

11

9. SERVICE INFORMATION

In the event that your CXA240 should require servicing, 

please follow these instructions:
1.   Call EAW Commercial Tech Support at 1-888-337-7404, 

7 am to 5 pm PST (Monday-Friday), to verify the problem 

and obtain a Return Authorization (RA) Number. Be sure to 

have the serial number of the unit when you call. You must 

have a Return Authorization Number in order to obtain 

warranty service at the factory or at an authorized service 

center. You can also email EAW Commercial Tech Support 

at: [email protected]

2.   Pack the unit in its original packaging. THIS IS VERY 

IMPORTANT. EAW Commercial is not responsible for 

any damage that occurs during shipping due to non-

conventional packaging. Original packaging helps to 

minimize the possibility of shipping damage.

3.   Include a legible note stating your name, (no P.O. boxes), 

daytime phone number, Return Authorization Number, and 

a detailed description of the problem, including how we 

can duplicate it.

4.   Write the Return Authorization Number in BIG BOLD PRINT 

on the top of the box.

5.   Tech Support will tell you where to ship the unit when you 

call for an RA Number. We suggest insurance for all forms 

of cartage. 

10. EAW COMMERCIAL   
WARRANTY

Warranty

: LOUD Technologies Inc. requires its authorized 

EAW Commercial distributors to abide by the following 

warranty terms for all EAW Commercial brand products 

(all dates are from the date of delivery from an Authorized 

EAW Commercial Distributor to the end user/installation 

site): Loudspeakers – 5 years; Active Electronics – 5 years; 

Accessories – 2 years.

What Is Covered:

 Defects in workmanship and materials 

and against malfunctions. EAW Commercial distributors 

must remedy all such defects and malfunctions without 

charge for parts or labor if the warranty applies. Final 

determination of warranty coverage lies solely with each 

authorized EAW Commercial distributor.

What Is Not Covered:

 This warranty does not extend 

to damage or malfunctions resulting from, but not limited 

to, shipment, improper installation, misuse, neglect, 

abuse, normal wear, accident, or to any product on 

which the serial number has been modified or removed. 

Exterior defects in or damage to the exterior appearance 

are specifically excluded from this warranty. EAW 

Commercial distributors shall not be liable for incidental 

or consequential damages resulting from the use of EAW 

Commercial products. Repairs and/or modifications by 

other than an Authorized EAW Commercial Distributor 

automatically voids this warranty.

CXA240 BLOCK DIAGRAM

L

R

INPUT 1

INPUT 2

RCA INPUT

LED

METER

INPUT

LEVEL

MAIN

POWER

AMPLIFIER

OUTPUT

TRANSFORMER

100V

70V

COM

4 ohm

COM

Содержание CXA240

Страница 1: ...T TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE RISK OF HAZARDOUS ENERGY MAKE PROPER SPEAKER CONNECTION SEE INSTRUCTIONS BEFORE USING WARNING INPUT 6 3A...

Страница 2: ...h This switch is located on the front panel and should remain readily accessible to the user WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture WARNI...

Страница 3: ...z determined by a rear panel voltage select switch and is supplied by a detachable IEC power cord A rear panel terminal strip connection is provided for connecting an external 24 VDC backup battery wi...

Страница 4: ...rn down the volume level so the top two LEDs do not light otherwise the outgoing signal will clip and distort 3 POWER Use this rocker switch to turn the unit on or off This connects disconnects the AC...

Страница 5: ...e DC rail supply to the power amplifier Make sure that the AC supply is turned off before removing the fuse When you are sure that all is safe press in the fuse cover and turn it counter clockwise Rep...

Страница 6: ...ransformer with an input voltage equal to that of the line 70 V or 100 V Make sure that the sum of the power capacities of the speakers does not exceed 90 of the amplifier s rated output power 216 W C...

Страница 7: ...The two inputs are summed to mono Use balanced connections where possible instead of RCA unbalanced connections as these offer better rejection of noise Use high quality three conductor shielded cabl...

Страница 8: ...heatsink Leave at least one rack space above and below and at least 6 inches behind the chassis to allow proper ventilation If the amplifier should overheat a thermal switch turns off the power ampli...

Страница 9: ...CXA240 9 7 TYPICAL HOOKUP DIAGRAM CXA240 AMPLIFIER F U S E F U S E F U S E MIXER OR PREAMPLIFIER EAW DX810 MIXER AMPLIFIER EAW CAM150...

Страница 10: ...5 50 60 Hz 24 VDC battery Power Consumption 486 W Physical Dimensions HxWxD 6 1 in 156 mm x 19 0 in 483 mm x 14 5 in 368 mm Including Feet Weight 34 1 lb 15 5 kg Warranty 5 years parts and labor DISCL...

Страница 11: ...nty LOUD Technologies Inc requires its authorized EAW Commercial distributors to abide by the following warranty terms for all EAW Commercial brand products all dates are from the date of delivery fro...

Страница 12: ...ies Inc Company EAW Commercial One Main Street Whitinsville MA 01588 USA TEL toll free within US Canada 888 337 7404 TEL outside US 425 892 6503 FAX 425 485 1152 www eawcommercial com 2004 LOUD Techno...

Отзывы: