Tel 800 992 5013 / +1 508 234 6158
|
www.eaw.com
26
AC6
Quickstart Guide
• 3mm Allen Wrench
• Flat head screw driver
• Mallet or Hammer
• Torque Driver (with 3mm Hex/Allen bit)
• Thread locker, Medium Strength - Loctite
242, Hernon 423, or equivalent.
Required Tools & Supplies
Remove cable knock outs (as needed)
• Place a flat head screwdriver into the slot of
a ¾” knockout that is to be removed.
• Hit the end of the screw driver to shear
the knockout and remove the rest of the
knockout by hand if necessary.
• If burrs remain, remove them with a
countersink or deburring tool.
Note: ½” knockout size is for reference only and must be drilled out.
Joint Cover (each kit)
Qty
Description
1
Input Joint Cover
1
Input Joint Cover Gasket
1
Joint Gasket
18
M5 x 18 Buttonhead Head
Allen Drive Screws
3
3/4" Gland Nuts
• To make the connection water tight, a ¾” (or ½” as needed) gland nut (included),
rigid conduit adapter or flexible conduit adapter (not included) should be fitted to
each knockout prior to installing cables.
• Silicone sealant should be used as needed to make any cable connections water
tight.