EAW AC6 Скачать руководство пользователя страница 1

Quickstart Guide

AC6

Содержание AC6

Страница 1: ...Quickstart Guide AC6...

Страница 2: ...workers associated with system deployment enjoy a working understanding of the critical life safety issues associated with large scale sound system use Internal Processing Amplification As is true of...

Страница 3: ...e in venue optimization supplemental software such as Rational Acoustics Smaart may be desired but this is not required for basic system operation Always ensure that your EAW Resolution software and A...

Страница 4: ...me directivity from the same physical length regardless of whether this length is made up of 8 10 12 or 15 components The determining factor is the length of the array itself and how that length affec...

Страница 5: ...rray length must be considered Venue Design Examples The following section contains a variety of venue examples with recommended systems for each The venue type capacity recommended system size and ex...

Страница 6: ...erspective THEATER 70 X 75 SEATING CAPACITY 670 PEOPLE Equipment List 4x AC6 2x SB828P Plan Elevation Perspective AUDITORIUM 70 X 80 SEATING CAPACITY 510 Equipment List 4x AC6 2x SBX218 1x MKD1096 4x...

Страница 7: ...e computer is connected to the same Ethernet network as the networked loudspeaker system Communications is established by clicking Network on the Menu bar and selecting Connect Resolution 2 will then...

Страница 8: ...and connecting to the system This will ensure you know how the Arrays will need to be configured However this is not required and you can simply fly the arrays and connect Resolution 2 to your system...

Страница 9: ...be assigned or associated with a modeled Array in the model by simply clicking on the Array in the list and dragging it on to the appropriate modeled Array Note the physical Array and modeled Array m...

Страница 10: ...AC6 Quickstart Guide Double clicking the teal input assignment button will open the Array Configuration dialog Right clicking a module in an Array will open a menu with options to Insert Item Above I...

Страница 11: ...module will open the Diagnostics Window for that module Updating Firmware on AC6 NOTE Before starting Firmware update please turn the Windows Firewall off NOTE It is highly recommended you run the fir...

Страница 12: ...Tel 800 992 5013 1 508 234 6158 www eaw com 12 AC6 Quickstart Guide Select the firmware file eawfw in C ProgramData EAW Resolution Windows must be set to show hidden files and folders...

Страница 13: ...ay result in damage injury or death 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Clean only with a dry cloth 6 Install loudspeaker in accordance...

Страница 14: ...ounted spacing should be 39 0 990 6mm from centerline to centerline This can be measured from bracket top to bracket top d Product is designed for vertical mounting only Use of level is encouraged to...

Страница 15: ...posite direction For symmetrical L R setups the bracket will mount in mirror fashion c Locate the flytrack studs attached to the bracket inside the flytrack on the back of the cabinet The two locating...

Страница 16: ...alog audio and dry contacts can be looped from either end Refer to user manual for more information c Starting from the bottom of the array and moving to the top mount each AC6 to the respective wall...

Страница 17: ...M6x20 screws attach the cover to the wall bracket to hide the hinge mechanism Do not overtighten Panned wall bracket Flush Mount Bracket Instructions Tools needed 10mm wrench or hex driver 4mm allen...

Страница 18: ...e rated at 175lb 80kg b Mark the wall or structure where brackets will be mounted Refer to the included customer drawing 2071359 CD for mounting pattern Use the points that provide the highest amount...

Страница 19: ...must be mounted in the orientation in which they should be connected Either from the top or from the left or right side c Locate the flytrack studs attached to the bracket inside the flytrack on the b...

Страница 20: ...s d If WP covers are being used install the covers at this stage e Using two people line up the flush wall mount to the AC6 bracket then slide into place f The button head screws M6x35 on the cabinet...

Страница 21: ...k to Stinger in order to array straight with no tilt angle a M10 bolts or pins for portable use 2 Using steps above attach AC6 cabinet bracket for flush mount 3 Attach stinger to AC6 using M10 bolts I...

Страница 22: ...Tel 800 992 5013 1 508 234 6158 www eaw com 22 AC6 Quickstart Guide 4 Attach 1 2 shackle to stinger or mohawk 5 Suspend AC6...

Страница 23: ...ckstart Guide Pole Mount 1 Place AC6 Upside down 2 Remove M5 Screws from bottom 3 Attach Pole cup adapter with M5x20 screws lock washer and large flat washer 4 Using 2 people place AC6 on speaker stan...

Страница 24: ...d and discarded e Inspect hardware securing the u bracket to the mounting surface for corrosion or looseness Tighten loose hardware and consider installing hardware locking methods Replace and discard...

Страница 25: ...of AC6 modules Location and quantity of audio network and power cabling One end of each cable must be left unterminated to pass through the knockouts Identify if covers will be fitted before or after...

Страница 26: ...d remove the rest of the knockout by hand if necessary If burrs remain remove them with a countersink or deburring tool Note knockout size is for reference only and must be drilled out Joint Cover eac...

Отзывы: