4
XFG1 HD IP Fixed Optical Camera Station
XFG1 HD IP OPtIcal FIXeD camera
TMOX001.A September 2021 www.eaton.com
1.0 INTRODUCTION
This camera, intended for use in potentially explosive gas and
dust atmospheres, is available in versions suitable for use in
the following gas/dust groups: IIB IIIC.
The Ex enclosure is manufactured from a UV stable glass
reinforced polyester with a rugged thermoplastic Sunshield.
GRP and 316 Stainless Steel mounting brackets, cover screws
and fixings are incorporated throughout thus ensuring a
corrosion free product.
An uncertified version is available for use in non-explosive
atmospheres.
2.0 GENERAL SAFETY MESSAGES AND
WARNINGS
All instructions and safety messages in this manual must be
followed to allow safe installation of the device. The device
must only be installed and maintained by correctly trained
site personnel/installers. See also certified annex for special
conditions for safe use.
i. To reduce the risk of ignition of hazardous atmospheres
and shock, do not apply power to the device until installation
has been completed and the device is fully sealed and
secured.
ii. To reduce the risk of ignition of hazardous atmospheres
and shock, keep device tightly closed when the circuit is
energised.
iii. Before removing the cover for installation or
maintenance, ensure that the power to the device is
isolated.
iv. Following installation, test the device to ensure correct
operation.
v. Following installation ensure a copy of this manual is
made available to all operating personnel
vi. When installing the device, requirements for selection,
installation and operation should be referred to e.g. IEE
Wiring Regulations and the ‘National Electrical Code’ in
North America. Additional national and/or local requirements
may also apply.
vii. Cable termination should be in accordance with the
specification applying to the required application. MEDC
recommends that all cables and cores should be correctly
identified. Please refer to the wiring diagram in this manual
(or separate diagram provided with the unit).
viii. Ensure that only the correct listed or certified cable
glands are used and that the assembly is correctly earthed.
ix. Ensure that only the correct listed or certified stopping
plugs are used to blank off unused gland entry points in
accordance with EN/IEC60079-14 clauses 16.3, 16.4 & 16.5
and that the NEMA/IP rating of the unit is maintained.
x. MEDC recommend the use of a sealing compound
such as HYLOMAR PL32 on the threads of all glands and
stopping plugs and/or a suitable sealing washer in order to
maintain the IP rating of the unit.
xi. The internal earth terminal must be used for protective
earthing when required. Do not remove the internal ground
strap from the earth terminal where fitted.
xii. For units with metric entries; gland continuity and
earthing may be achieved with an optional external
earth plate. If the external plate is fitted, a thread sealing
compound such as HYLOMAR PL32 must be employed to
maintain the IP rating of the unit.
xiii. When installing the device, MEDC recommends the use
of stainless-steel fasteners. Ensure that all nuts, bolts and
fixings are secure.
xiv. The unit should never be positioned with the sunshield
horizontal facing down.
xv. The purchaser should make the manufacturer aware
of any external effects or Aggressive substances that the
equipment may be exposed to.