Eaton Vickers VMQ125S Series Скачать руководство пользователя страница 6

Model Code —
Double Pumps

Table 2.

Model Code Breakdown

6

EATON Vickers 

Single, Double, Triple and Thru-drive Pumps  Overhaul Service Manual  V-PUVN-TS001-E  October 2002

* Verify shaft torque ratings meet or exceed input torque requirements

Series designation

VMQ2  –  Vane pump double series

Frame size (front section)

25

10-90 cm

3

/r 

(0.62-5.49 in

3

/r)

35

90-158 cm

3

/r  

(5.49-9.64 in

3

/r)

45

140-215 cm

3

/r 

(8.54-13.12 in

3

/r)

Frame size (rear section)

25

10-90 cm 

3

/r 

(0.62-5.49 in

3

/r)

35

90-158 cm 

3

/r

(5.49-9.64 in 

3

/r)

Pump type

S

Standard

Displacement 
(front section)

Frame size 25
010 –

10 cm 

3

/r (0.62 in 

3

/r)

016 –

16 cm 

3

/r (0.98 in 

3

/r)

020 –

20 cm 

3

/r (1.23 in 

3

/r

025 –

25 cm 

3

/r (1.58 in 

3

/r)

032 –

32 cm 

3

/r (1.96 in 

3

/r)

040 –

40 cm 

3

/r (2.44 in 

3

/r)

045 –

45 cm 

3

/r (2.75 in 

3

/r)

050 –

50 cm 

3

/r (3.05 in 

3

/r)

063 –

63 cm 

3

/r (3.84 in 

3

/r)

071 –

71 cm 

3

/r (4.33 in 

3

/r)

080 –

80 cm 

3

/r (4.88 in 

3

/r)

090 –

90 cm 

3

/r (5.49 in 

3

/r)

Frame size 35
090 –

90 cm 

3

/r (5.49 in 

3

/r)

100 –

100 cm 

3

/r (6.10 in 

3

/r)

112 –

112 cm 

3

/r (6.83 in 

3

/r)

125 –

125 cm 

3

/r (7.63 in 

3

/r)

135 –

135 cm 

3

/r (8.24 in 

3

/r)

140 –

140 cm 

3

/r (8.54 in 

3

/r)

158 –

158 cm 

3

/r (9.64 in 

3

/r)

Frame size 45
140 –

140 cm 

3

/r (8.54 in 

3

/r)

160 –

160 cm 

3

/r (9.76 in 

3

/r)

180 –

180 cm 

3

/r (10.98 in 

3

/r)

195 –

195 cm 

3

/r (11.89 in 

3

/r)

215 –

215 cm 

3

/r (13.12 in 

3

/r)

Displacement 
(rear section)

Frame size 25
010 –

10 cm 

3

/r (0.62 in 

3

/r)

016 –

16 cm 

3

/r (0.98 in 

3

/r)

020 –

20 cm 

3

/r (1.23 in 

3

/r)

025 –

25 cm 

3

/r (1.58 in 

3

/r)

032 –

32 cm 

3

/r (1.96 in 

3

/r)

040 –

40 cm 

3

/r (2.44 in 

3

/r)

045 –

45 cm 

3

/r (2.75 in 

3

/r)

050 –

50 cm 

3

/r (3.05 in 

3

/r)

063 –

63 cm 

3

/r (3.84 in 

3

/r)

071 –

71 cm 

3

/r (4.33 in 

3

/r)

080 –

80 cm 

3

/r (4.88 in 

3

/r)

090 –

90 cm 

3

/r (5.49 in 

3

/r)

Frame size 35
090 –

90 cm 

3

/r (5.49 in 

3

/r)

100 –

100 cm 

3

/r (6.10 in 

3

/r)

112 –

112 cm 

3

/r (6.83 in 

3

/r)

125 –

125 cm 

3

/r (7.63 in 

3

/r)

135 –

135 cm 

3

/r (8.24 in 

3

/r)

140 –

140 cm 

3

/r (8.54 in 

3

/r)

158 –

158 cm 

3

/r (9.64 in 

3

/r)

Front flange mounting style

A

(Frame size 25 only)
SAE B 2-bolt

101,60 (4.000) x 9,4 
(0.37) pilot

14,4 (0.57) slots on 
146,0 (5.75) bolt circle

B

(Frame sizes 35 & 45 only)
SAE C 2-bolt

127,00 (5.000) x 12,4 
(0.49) pilot

17,6 (0.69) slots on 

181,0 (7.13) bolt circle

C

(Frame size 25 only)

ISO 3019/2 100A2HW 
2-bolt

100,00 (3.937) x 9,2 
(0.36) pilot

14,1 (0.56) slots on 

140,0 (5.51) bolt circle

D

(Frame sizes 35 & 45 only)

ISO 3019/2 125A2HW 
2-bolt

125,00 (4.921) x 9,2 
(0.36) pilot

18,1 (0.71) slots on 

180,0 (7.09) bolt circle

Adapter flange 

0

None (standard 
double pump)

Input shaft type*

01

SAE J744 keyed

Frame size 25: 

25,40 (1.000)

Frame size 35: 

31,75 (1.250)

Frame size 45: 

38,10 (1.500)

02

SAE J744 splined

Frame size 25: B-B

Frame size 35: C

Frame size 45: C-C

03

ISO 3019/2 keyed

Frame size 25: 

25,00 (0.984)

Frame size 35: 

32,00 (1.260)

Frame size 45: 

40,00 (1.575)

05

SAE J744 keyed

Frame size 25: 

31,75 (1.250)

Frame size 35: 

38,10 (1.500)

Frame size 45: 

44,45 (1.750)

06

SAE J744 splined

Frame size 25: C

Frame size 35: C-C

Frame size 45: D

07

ISO 3019/2 keyed

Frame size 25: 

32,00 (1.260)

Frame size 35: 

40,00 (1.575)

09

SAE J744 Spline

Frame size 45: C

Output shaft coupling

00

None (standard 
double pump)

Inlet port type

A

SAE J518 4-split flange

B

ISO 6162 4-bolt flange

Front outlet port type

A

SAE J518 4-bolt flange

B

ISO 6162 4-bolt flange

Rear outlet port type

A

SAE J518 4-bolt flange

B

ISO 6162 4-bolt flange

Front outlet port position

Viewed from cover end of
pump

A

Opposite inlet port

B

90° CCW to inlet port

C

In-Line with front 
inlet port

D

90° CW to inlet port

Rear outlet port position

Viewed from cover end 
of pump

A

135° CCW to inlet port
(not available with 2525)

B

45° CCW to inlet port
(not available with 2525)

C

45° CW to inlet port 
(not available with 2525)

D

135° CW to inlet port 
(not available with 2525)

E

Opposite inlet port 
(2525 only)

F

90° CCW to inlet port
(2525 only)

G

In-line with inlet port
(2525 only)

H

90° CW to inlet port 
(2525 only)

Shaft Seal

A

Single, primary

B

Double, secondary
(spring side out)
Recommended for wet
mount applications 

Seal Type

N

Buna-N

V

Viton

W

Buna-N with Viton 
shaft seal(s)

Shaft rotation

Viewed from shaft end 
of pump

L

Left Hand (CCW)

R

Right Hand (CW)

Special features

00

None

Paint

O

None

A

Blue

Customer identification

O

None

Design code

30

30 design
Installation dimensions
remain unchanged for
design numbers 30 to 39
inclusive.

34  35

33

32

30  31

29

28

27

26

25

24

23

22

20  21

18  19

17

16

13 14 15

10 11 12

9

7  8

5  6

1  2  3  4

VMQ2   **   **   S   ***    ***   *   0   **   00   *   *   *   *   *   *   *   *   00   *   0   30

1  2  3  4

5  6

7  8

9 10  11  12 13  14  15 16

17

18  19 20  21

22

23

24

25

26

27

28

29 30  31

32

33

34  35

Содержание Vickers VMQ125S Series

Страница 1: ...Single Double Triple and Thru Drive Pumps Overhaul Service Manual VMQ125S VMQ135S VMQ145S VMQ125T VMQ135T VMQ145 VMQ22525 VMQ23525 VMQ24525 VMQ24535 VMQ3352525 VMQ3453525 Series 30 Design...

Страница 2: ...Balance 9 D Wafer Plate Operation 9 E Outlet Bodies 10 IV INSTALLATION AND OPERATING INSTRUCTIONS A Installation Drawings 10 B Mounting and Drive Connections 10 C Shaft Rotation 11 D Piping and Tubing...

Страница 3: ...cribed in detail and their theory of operation is discussed in addition to instructions for installation maintenance and overhaul The general series of models covered are VMQ125S VMQ135S VMQ145S VMQ12...

Страница 4: ...V PUVN TS001 E October 2002 Section II Description cont Figure 1b Cutaway View of Typical High Performance VMQ Double Vane Pump Figure 1c Cutaway View of Typical High Performance VMQ Triple Vane Pump...

Страница 5: ...e 35 D 45 CW to mounting flange frame size 35 SAE B E In line with mounting flange frame sizes 25 45 F 90 to mounting flange frame sizes 25 45 G 45 CCW to mounting flange frame size 35 H 45 CW to moun...

Страница 6: ...3019 2 100A2HW 2 bolt 100 00 3 937 x 9 2 0 36 pilot 14 1 0 56 slots on 140 0 5 51 bolt circle D Frame sizes 35 45 only ISO 3019 2 125A2HW 2 bolt 125 00 4 921 x 9 2 0 36 pilot 18 1 0 71 slots on 180 0...

Страница 7: ...SAE J744 127 2 127 00 5 000 x 12 4 0 49 pilot 17 6 0 69 slots on 181 0 7 13 bolt circle B ISO 3019 2 125A2HW 2 bolt 125 00 4 921 x 9 2 0 36 pilot 18 1 0 71 slots on 180 0 7 09 bolt circle Input shaft...

Страница 8: ...rt causes the vanes to follow the elliptical inner surface of the ring Radial movement of the vanes and turning of the rotor causes the chamber volume between the vanes to increase as the vanes pass t...

Страница 9: ...vel of the pump The position of the wafer plates in the cartridge kit can be seen in Figure 5 VMQ wafer plates have a bronze finish that rides next to the rotor and provides excellent wear and thermal...

Страница 10: ...ction IV Installation and Operating Instructions A Installation Drawings See the series 30 VMQ product catalog for installation dimensions B Mounting and Drive Connections Eaton high performance vane...

Страница 11: ...the system and or by proper filtration of the air 5 Proper oil filling and servicing of filters breathers reservoirs etc cannot be overemphasized 6 Good system and reservoir design will insure that ae...

Страница 12: ...he reservoir and air will be recycled through the system 3 Aerated fluid can also be caused by ingestion of air through the pipe joints of inlet lines high velocity discharge lines cylinder rod packin...

Страница 13: ...rough the filter which would ordinarily be trapped or can cause the bypass to open resulting in a partial or complete loss of filtration 4 Air bubbles in the reservoir can ruin the pump and other comp...

Страница 14: ...he reservoir is above the intake pipe opening Check the minimum drive speed which may be too slow to prime the pump Vane s stuck in the rotor slots s Disassemble the pump Check for dirt or metal chips...

Страница 15: ...afts Outlet Support Plate Inlet Cover Assembly Pin Kit Seals Housing Bolt Inlet Wafer Plate Inlet Support Plate Cartridge Torque Pin Vane and Under Vane Pin Rotor Retaining Ring Back Up Ring Anti Rota...

Страница 16: ...sing Torque Specs INLET HOUSING THRU DRIVE ADAPTOR SAE A SAE B THRU DRIVE ADAPTOR SAE C ISO NM SAE ft lb ISO NM SAE ft lb ISO NM SAE ft lb Dry Oiled Dry Oiled Dry Oiled Dry Oiled Dry Oiled Dry Oiled V...

Страница 17: ...ry Oiled Dry Oiled Dry Oiled Dry Oiled VMQ22525 153 16 115 12 113 11 85 9 VMQ23525 305 31 229 23 225 23 169 17 153 16 115 12 113 11 85 9 VMQ24525 305 31 229 23 225 23 169 17 153 16 115 12 113 11 85 9...

Страница 18: ...AE ft lb ISO NM SAE ft lb ISO NM SAE ft lb Dry Oiled Dry Oiled Dry Oiled Dry Oiled Dry Oiled Dry Oiled VMQ22525 153 16 115 12 113 11 85 9 VMQ23525 305 31 229 23 225 23 169 17 153 16 115 12 113 11 85 9...

Страница 19: ...use protective jaws to avoid damage to the body and its machined surfaces Mark the pump body and cover for correct reassembly Remove the necessary screws to disassemble the housing Remove all Housing...

Страница 20: ...VMQ 20 in lb 2 28 Nm 45 VMQ 40 in lb 4 55 Nm All parts must be thoroughly clean and kept clean during inspection and assembly 1 Remove the shaft seal s O rings back up rings and seal pack subassemblie...

Страница 21: ...icate the bullet with petroleum jelly and carefully push the shaft through the seal s until the bearing is within the body Install the large spiralox ring into the body snap ring groove behind the bea...

Страница 22: ...October 2002 Eaton 14615 Lone Oak Road Eden Prairie MN 55344 USA Tel 952 937 9800 Fax 952 974 7722 www hydraulics eaton com Eaton 46 New Lane Havant Hampshire PO9 2NB England Tel 44 23 92 486 451 Fax...

Отзывы: