Section II 

 Description 

This manual contains operation, service and overhaul
information for Vickers hydro-cushion type pressure control
valves.

The 

R

 and the 

RC

 series valves are identical in operation

except the 

R

 series limits flow to one direction - from the

primary port to the secondary port. The 

RC

 series,

provided with an integral check valve, permits reverse free
flow from the secondary port to the primary port when the
valve is closed.

Since these valves can be internally or externally drained,
directly or remotely operated, they are adaptable to a wide
range of applications depending on the position of the covers
in relation to the body.

Figure 1. 6.

Type 1

Type 2

Type 3

Type 4

Drain
Plugged

Control

Port

Plugged

Remote

Control

Connection

Offset

from

Body

Passage

External Drain

Connection

Drain
Plugged

Align 

with 

Body 

Passage

Align 

with 

Body 

Passage

Align 

with 

Body 

Passage

Offset from

Body Passage

NOTE:

Cover positions illustrating threaded style valves apply to gasket mounted valves also, except the cover ports remain

plugged. External connecitons are made directly to the mounting surface or subplate fo the RG, RCG Series.

The four standard combinations are designated as Types 1,
2, 3, and 4. Each type is available with or without the integral
check valve, permitting reverse free flow.

TYPE 1

 - is internally drained and directly operated. It is

used as a relief valve for overload protection when the sys-
tem pressure does not exceed 500 PSI. In this application
the secondary port is connected directly to tank. Or, if pro-
vided with the integral check valve, it can be used as a coun-
terbalance or brake valve.

TYPE 2

 - is externally drained and directly operated. It is

used as a sequence valve permitting pressure buildup for
the second phase of a two phase cycle, while maintaining a
minimum pressure at the primary port for a holding opera-
tion, i.e., a clamp and work stroke cycle.

TYPE 3

 - is externally drained and remotely operated. It is

used as a sequence valve in the same manner as 

Type 2

except, being remotely operated, the valve can be used to
sequence independently of the primary pressure when pro-
vided with a separate pressure source.

TYPE 4

 - is internally drained and remotely operated. It is

used primarily as an unloading valve where the secondary
port must be connected directly to tank. Application of exter-
nal pressure permits the valve to open fully independent of
the primary pressure. Type 4 valves can also be used as
remotely operated counterbalance or brake valves when
provided with the integral check valve.

Содержание Vickers RF Series

Страница 1: ...I 3332 S Revised 9 1 87 Pressure Control Valves Hydro Cushion Type RF RG and RT Series RCF RCG and RCT Series Vickers Pressure Relief Overhaul Manual...

Страница 2: ...2 EEaton Hydraulics Incorporated 2000 All Rights Reserved...

Страница 3: ...ble 1 Installation and Parts Drawings 4 Table 2 Model Code Breakdown 4 II Description 5 Figure 1 5 III Installation 6 Figure 2 6 IV Operation 7 V Special Features 8 Figure 3 8 VI Overhaul 9 A Disassem...

Страница 4: ...low Installation F Flange connected G Gasket mounted T Threaded connections Pressure Rating A 75 250 PSI with pilot piston B 125 500 PSI with pilot piston D 250 1000 PSI with pilot piston F 500 2000 P...

Страница 5: ...s are designated as Types 1 2 3 and 4 Each type is available with or without the integral check valve permitting reverse free flow TYPE 1 is internally drained and directly operated It is used as a re...

Страница 6: ...depending on the application and type of valve used The RG RCG series gasket mounted valves are teed into the supply line The tee connection is piped to the bottom or pressure port in the subplate or...

Страница 7: ...the pressure setting of the valve When the primary pressure decreases compression of the spring overcomes the hydraulic force effective on the piston and spool closes blocking flow to chamber B Fluid...

Страница 8: ...Valve installed between the Gage Ports Primary Port outlet to ram or control return flow Normally open Spool Type O Auxiliary Control Type P Control Pressure Port 2 Orifice of size required drilled in...

Страница 9: ...ng Table 3 For complete disassembly See Figure 4 remove the valve from the installation Dismantle in the same order as the key index numbers assigned to the exploded view B Reassembly 14 Reassemble in...

Страница 10: ...ain spool plugged 3 Main spool stuck in open position 4 Control piston binding in up position Readjust valve to proper setting Remove spool Blow out hole with fil tered compressed air Remove spool Che...