6
Instruction Booklet
IB131006EN
Effective March 2019
Instructions for installation,
operation, and maintenance of type
VCP-W vacuum circuit breakers
EATON
www.eaton.com
1. Introduction
1.1 Preliminary comments and safety pre-cautions
This technical document is intended to cover most aspects associ-
ated with the installation, operation, and maintenance of Type
VCP-W, VCPW-SE, VCP-WC,and VCPWND vacuum circuit breakers.
It is provided as a guide for authorized and qualified personnel only.
Please refer to the specific WARNING and CAUTION in Paragraph
1.1.2 before proceeding past Section 1. If further information is
required by the purchaser regarding a particular installation, applica-
tion, or maintenance activity, an Eaton representative should be
contacted.
1.1.1 Warranty and liability information
NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES
OF FITNESS FOR A PARTICULAR PURPOSE OF MERCHANTABILITY, OR
WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE,
ARE MADE REGARDING THE INFORMATION, RECOMMENDATIONS
AND DESCRIPTIONS CONTAINED HEREIN.
In no event will Eaton be
responsible to the purchaser or user in contract, in tort (including
negligence), strict liability or otherwise for any special, indirect, inci-
dental, or consequential damage or loss whatsoever, including but
not limited to damage or loss of use of equipment, plant or power
system, cost of capital, loss of power, additional expenses in the
use of existing power facilities, or claims against the purchaser or
user by its customers resulting from the use of the information and
descriptions contained herein.
1.1.2 Safety precautions
All safety codes, safety standards, and/or regulations must be
strictly observed in the installation, operation, and maintenance of
this device.
m
WARNING
THE WARNINGS AND CAUTIONS INCLUDED AS PART OF THE
PROCEDURAL STEPS IN THIS DOCUMENT ARE FOR PERSONNEL SAFETY
AND PROTECTION OF EQUIPMENT FROM DAMAGE. AN EXAMPLE OF A
TYPICAL WARNING LABEL HEADING IS SHOWN ABOVE TO FAMILIARIZE
PERSONNEL WITH THE STYLE OF PRESENTATION. THIS WILL HELP TO
INSURE THAT PERSONNEL ARE ALERT TO WARNINGS, WHICH MAY
APPEAR THROUGHOUT THE DOCUMENT. IN ADDITION, CAUTIONS ARE
ALL UPPER CASE AND BOLDFACE AS SHOWN BELOW.
m
CAUTION
COMPLETELY READ AND UNDERSTAND THE MATERIAL PRESENTED IN
THIS DOCUMENT BEFORE ATTEMPTING INSTALLATION, OPERATION,
OR APPLICATION OF THE EQUIPMENT. IN ADDITION, ONLY QUALIFIED
PERSONS SHOULD BE PERMITTED TO PERFORM ANY WORK ASSOCIATED
WITH THE EQUIPMENT. ANY WIRING INSTRUCTIONS PRESENTED IN THIS
DOCUMENT MUST BE FOLLOWED PRECISELY. FAILURE TO DO SO COULD
CAUSE PERMANENT EQUIPMENT DAMAGE.
1.2 General information
The purpose of this book is to provide instructions for unpack-
ing, storage, use, operation, and maintenance of Type VCP-W,
VCPW-SE, VCP-WC, and VCPW-ND vacuum circuit breakers. These
circuit breakers are horizontal drawout type removable interrupting
elements designed for use in VacClad-W Metal-Clad switchgear
and appropriate VCP-W modules. They provide reliable control and
protection for medium voltage electrical equipment and circuits. All
VCP-W circuit breaker elements are designed to ANSI Standards for
reliable performance, ease of handling, and simplified maintenance.
In addition, some VCP-W circuit breakers have been tested in accor-
dance with IEC Standards for applications around the world.
The VCPW-SE circuit breaker element is a VCP-W circuit breaker
designed specifically for special environment applications and operat-
ing conditions through 27 kV. The VCPW-ND circuit breaker element
is a narrow design VCP-W circuit breaker designed specifically for
use in 5 kV applications where floor space requirements would
not allow the industry standard 36 in. (914.4 mm) wide switchgear.
From this point on, all circuit breaker elements will be referred to as
Type VCP-W unless the reference is specific to a particular design.
The VCP-WC circuit breaker element is a VCP-W circuit breaker
designed and tested for extra capabilities beyond one or more of the
preferred ratings of the applicable ANSI Standard.
m
WARNING
SATISFACTORY PERFORMANCE OF THESE BREAKERS IS CONTINGENT
UPON PROPER APPLICATION, CORRECT INSTALLATION, AND ADEQUATE
MAINTENANCE. THIS INSTRUCTION BOOK MUST BE CAREFULLY READ
AND FOLLOWED IN ORDER TO OBTAIN OPTIMUM PERFORMANCE FOR
LONG USEFUL LIFE OF THE CIRCUIT BREAKER ELEMENTS.
m
WARNING
THE CIRCUIT BREAKERS DESCRIBED IN THIS BOOK ARE DESIGNED AND
TESTED TO OPERATE WITHIN THEIR NAMEPLATE RATINGS. OPERATION
OUTSIDE OF THESE RATINGS MAY CAUSE THE EQUIPMENT TO FAIL,
RESULTING IN DEATH, BODILY INJURY, AND PROPERTY DAMAGE.