Sonix Io Unit Technical Manual

SONIX IO TECHNICAL MANUAL  

TM366 / A  June 2022  www.eaton.com

Glossary

Abbreviation

Meaning

PA/GA

Public Address and General Alarm

Sonix

Sonix PA/GA System

A&B

Duplicated PA/GA system architecture

N+1

Hot spare PA/GA system architecture

AB+

Sonix improved redundancy architecture

Hmi

Human interface

BGM

Background music

Tick-tone

Short burst of tone repeated every few seconds, used to check the output of connected loudspeakers

Sense Test

Periodic test carried by Sonix amplifi er to check integrity of 100 V line

100 V line

High voltage loudspeaker connection line at nominal 100 V ac

MCB

Miniature Circuit Breaker

RCBO

Residual current circuit breaker with overcurrent protection

Unit ID/Number

Unique identifi er assigned to each of Sonix module, used to identify it to the 2Mx and SAS.

Priority

Number assigned to a Sonix audio source to facilitate system usage confl ict resolution, 31 (highest) to 1 (lowest)

PTT

Push to talk

FAT

Factory Acceptance Test

SAT

Site Acceptance Test

Larson’s Effect

When a microphone is acoustically coupled to the loudspeaker and generates feedback

2Mx

Sonix 2Mx Central controller

Amp / 350-d

Sonix 350 W Power Amplifi er with 100 V line output

Eol1

Sonix Remote End of Line unit

Eol8

Sonix Amplifi er to 100 V line interface unit (8 channel)

SP AD

Sonix Intelligent loudspeaker monitoring unit

Hmi-Br

Sonix intrinsically safe barrier (ATEX/IECEx) for connecting Hmi-5 in explosive atmospheres

Hmi-Mute

Sonix 100V loudspeaker mute (Ex/SA)

Hmi-26

Sonix Human Interface access panel

Hmi-5

Sonix Small Human Interface access panel

Io

Sonix Input / Output unit

Ms12

Sonix 12-message digital message store

Pbx

Sonix Private branch exchange interface unit

Pm10

Sonix Power Management unit

Vw2

Sonix Beacon control and monitoring unit (2 channel)

SAS

Sonix Administration Software

Amp Bus

A 2Mx bus, used to communicate with and control Sonix Amplifi er units

HMI Bus

A 2Mx bus, used to communicate with and control Sonix Hmi units

I/O Bus

A 2Mx bus, used to communicate with and control Sonix input/output devices: IG, Io and Ms12

Beacon Bus

A 2Mx bus, used to communicate with and control Sonix Vw2 units

Power Bus

A 2Mx bus, used to communicate with and control Sonix Pm10 units

Global Bus

A 2Mx bus, used to communicate with SAS application

Sync

A 2Mx bus used to communicate with the second 2Mx unit when PA/GA system is confi gured as A&B, AB+ or N+1 

system

Содержание SONIX Io

Страница 1: ...SONIXTM Io Input Output Unit SonixTM lo Technical Manual...

Страница 2: ...S FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF...

Страница 3: ...s feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel...

Страница 4: ...Connecting to sources greater than 12 V 10 4 5 3 Polarity 10 4 6 Output connections 10 4 6 1 Extended voltage or duplicate output support 10 4 6 2 Polarity 10 5 AVAILABLE FEATURES 11 5 1 Alarm activat...

Страница 5: ...reporting 13 6 CONFIGURATION 14 6 1 Ping set 14 6 2 Programming the unit 14 7 CUSTOMISATION 14 7 1 Firmware customisation 14 8 MAINTENANCE 14 LIST OF FIGURES FIGURE 1 SONIX IO UNIT 7 FIGURE 2 DC POWE...

Страница 6: ...stem it is our prime interest that you remain safe throughout During this work you may be exposed to potentially hazardous voltages currents confined spaces and potentially hazardous industrial enviro...

Страница 7: ...6 Important Message input 17 Alarm Cancel input 18 Alarm Attenuate input 19 Auto Alarm Initiate inhibit input Table 1 Sonix Io features 3 3 1 Weight and dimensions Weight 700g Dimensions H x W 305 mm...

Страница 8: ...oming power supply cables Solid 4 0 mm2 Stranded 2 5 mm2 including sleeved or non sleeved ferrule 4 3 Earth connection The Sonix Io unit has an M4 stud for connection to Earth The Earth connection is...

Страница 9: ...OMPLIANT COMPLIANT c b a c b a Volt free Driven a b Normally Closed a b Normally Open Figure 4 Multiple Io Bus connections ote N As shown in Figure 4 Multiple Io Bus connections the order of connectio...

Страница 10: ...o avoid incorrect latch up This takes approximately 7 seconds 4 6 Output connections The Sonix Io output ports are volt free relay contacts with hardware selectable normally open or normally closed Th...

Страница 11: ...ix PA GA system but are considered as ETO 5 1 4 Alarm Inhibit The alarm inhibit input is used to prevent alarm activation of the Sonix Io Alarm inputs While the inhibit is active the alarm inputs are...

Страница 12: ...t to the routine speech chimes Selection of a chime creates a delay between activating PTT and routing voice to the PA GA system while the chime plays Warning As with routine emergency chime will over...

Страница 13: ...nt typically the collision alert warning or international maritime destress on vessels to allow that system to be activated when an alarm is running The alarm or multiple alarms it will be associated...

Страница 14: ...ramming is recommended 3 Disconnect unit from PA GA system 4 Isolate unit from third party connections 5 Connect programmer to J10 carefully observe the orientation key 6 Program unit using Eaton appr...

Страница 15: ...15 Sonix Io Unit Technical Manual SONIX IO TECHNICAL MANUAL TM366 A June 2022 www eaton com...

Страница 16: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...