background image

Pub 49440

Effective 01/02

2

Specifications

Table 1. 

Thermal and Mounting Specifications

* UL Tested.

Table 2. 

Insulation Specifications 

Environment Specifications 

EMC

Protection Degree: IP20

Pollution Degree: 3

Table 3. 

Output Specifications

Table 4. 

Control Specifications  

Product Selection

Table 5. 

Product Description and Item Selection  

Maintenance

Cooling fins must be kept clean and free from dust. The airflow 
must not be blocked. 

Wiring Diagram 

Figure 5. 

Wiring Diagram

Terminals 11 and 12 have no connection with the internal circuit. 
They are to be used in conjunction with a thermal overload pro-
tection or for other wiring purposes.

NOTE: Use thermal overload protection as required by 

the National Electric Code (NEC).

Specification

S701_03

S701_15, S701_25

Power dissipation (max.) 
continuous operation

4 Watts

2 Watts per Amp

Power dissipation (max.) 
intermittent operation

4 Watts x 
duty cycle

2 Watts per Amp x 
duty cycle

Cooling method

Natural 
convection

Natural convention

Operating temperature 
range, (see 

Table 6

)

-5° to 40°C 
[23° to 104°F]

-5° to 40°C*
[23° to 104°F]

Storage temperature

-20° to 80°C
[-4° to 176°F]

-20° to 80°C
[-4° to 176°F]

Mounting

Arbitrary

Vertical ±30°
Horizontal derate 50%

Description

Specification

Rated insulation voltage

Ui 660 Volt

Rated impulse withstand voltage

Uimp 4 kVolt

Installation category

III

Specification

S701_03

S701_15

S701_25

Operational 
Current (max.)

3.5A

AC-53a, AC-3

15A

AC-53a, AC-3

25A

AC-53a, AC-3

Leakage 
Current

5 mA

AC max.

4 mA

AC max.

5 mA

AC max.

Operational 
Current (min.)

50 mA

50 mA

50 mA

Max. Motor Size
208 – 230V AC

0.75 hp

(0.1 – 0.55 kW)

5-1/2 hp

(0.1 – 4.0 kW)

10 hp

(0.1 – 7.5 kW)

Max. Motor Size
380 – 415V AC

1.5 hp

(0.1 – 1.1 kW)

10 hp

(0.1 – 7.5 kW)

15 hp

(0.1 – 11.0 kW)

Max. Motor Size
400 – 480V AC

2 hp

(0.1 – 1.5 kW)

10 hp

(0.1 – 7.5 kW)

15 hp

(0.1 – 11.0 kW)

Max. Motor Size
400 – 600V AC

2 hp

(0.1 – 1.5 kW)

10 hp

(0.1 – 7.5 kW)

25 hp

(0.1 – 18.0 kW)

Control Voltage

S701_03

S701_15

S701_25

C
D

24 – 240
24 – 300

24 – 240

24 – 240

E
G

24 – 300
24 – 300

24 – 480
24 – 480

24 – 300
24 – 300

Pickup Voltage (max.)

20.4V AC/DC

Dropout Voltage (min.)

5V AC/DC

Control Current without operating

1 mA

Response Time (max.)

70 ms

Control Current / Power (max.)

15 mA / 2 VA

Line Voltage 
(V AC)

Item No.
(3.5 Amp)

Item No.
(15 Amp)

Item No.
(25 Amp)

208 – 240
400 – 415

S701C03N3S
S701D03N3S

S701C15N3S
S701E15N3S

S701C25N3S
S701E25N3S

440 – 480
550 – 600

S701E03N3S
S701G03N3S

S701E15N3S
S701G15N3S

S701E25N3S
S701G25N3S

Ramp Up Time

Adjustable from 0.5 - 10 seconds

Ramp Down Time

Adjustable from 0.5 - 10 seconds

Initial Torque with 
Optional Kick Start 

Adjustable from 0 – 85% of 
nominal torque

S 7 0 1 C 15 N 3 S

Soft Start Controller

Control Options
S - Standard
BP - Aux. Contact

Number of Poles

Options
N - No Special Options
B - Braking

Line Voltage
C - 208-240 V AC
D - 400-415 V AC
E - 400-480 V AC
G - 550-600 V AC

Amperage

03 = 3.5 Amps
15 = 15  Amps
25 = 25  Amps

2/T1

4/T2

6/T3

1/L1

3/L2

5/L3

11

12

A1

A2

Отзывы: