When  UPS  is  in  battery  mode,  the  number  of  the  icons  of  the 

charger-state section will vary according to the changeable capacity 

of the battery (pane). For example, there are five panes in Fig.A,(as 

the right picture of the Graphics(3) shows), so the corresponding 

number of icons is five rows(as the left picture of the Graphics(3) 

shows),, followed by this rule, 

              

 

                           

(3) 

 
 

5.2 Operation 
5.2.1 Start up operation 

Turn on the UPS in line mode 

 

Once mains power is plugged in, the UPS will charge the battery, 

at the moment, LCD shows that the output voltage is 0, which means 

UPS has no output. If it is expected to have output of bypass, you 

can set the bps “ON” by LCD setting menu. 

 

Press and hold the ON/OFF key for more than half a second to start 

the UPS, then it will start the inverter. 

 

Once started, the UPS will perform a self-test function, LED will 

light and go out circularly and orderly. When self-test finishes, 

it will come to line mode, the corresponding LED lights, UPS is 

working in line mode. 

Turn on the UPS by DC without mains power 

 

When mains power is disconnected, press and hold the ON/OFF key for 

more than half a second to start UPS. 

 

The operation of UPS in the process of start is almost the same as 

that when mains power is in. After finishing the self-test, the 

corresponding LED lights and UPS is working in battery mode. 

 

5.2.2 Turn off operation 

Turn off the UPS in line mode 

 

Press and hold the ON/OFF key for more than half a second to turn 

off the UPS and inverter. 

 

After UPS shutting down, LED go out and there is no output. If output 

is needed, you can set bps “ON” by LCD setting menu. 

Turn off the UPS by DC without mains power 

 

Press and hold the ON/OFF key for more than half a second to turn 

off the UPS. 

 

When turning off the UPS, it will do self-testing firstly. LED light 

and go out circularly and orderly until there is no display on the 

panel. 

Содержание RT 1250VA

Страница 1: ...e internal working principle and the relative protection functions This manual also contains information about the usage of the equipment Please obey the instructions and all the warning stated in the...

Страница 2: ......

Страница 3: ...s 8 4 3 UPS input connection 8 4 4 UPS output connection 9 4 5 Long backup external battery connection 9 4 6 Installation 10 5 Faceplate display operation and running 13 5 1 Faceplate display illumina...

Страница 4: ...the users equipments 5 No transfer time for the output of the UPS when the main power fails or restores It meets the high standard and high request of the precise instruments 6 The bypass function Wh...

Страница 5: ...e with the computer with intelligent UPS monitoring software through the RS232 interface All the parameters clearly display on the communication interface Computer can control multiple functions of th...

Страница 6: ...e the following 1 Don t use the UPS when the actual load exceeds the rated load 2 There are high capacity batteries in the standare type UPS You mustn t open the enclosure or it will lead to electric...

Страница 7: ...tention Static discharge sensitive Electric shock There are three levers of safety grade Dangerous Warning and Attention The remark is on the right side of the safety symbol the detailed comments is b...

Страница 8: ...6 3 Product Introduction 3 1 The appearance of the product Fig 1 Front Panel view Fig 2 RT 1250VA Rear Panel view Fig 3 RT 2000VA RT 3000VA Rear Panel view...

Страница 9: ...er to loads 6 Charger Standard unit provides 1A long backup unit provides 7A 14A 7 Battery Sealed Lead Acid Battery 8 Output filter Complete filtering the output of the UPS to provide the clean power...

Страница 10: ...e equipment 4 2 Notes 1 Please place the UPS in a clean stable environment avoid the vibration dust too humidity flammable gas and liquid corrosive 2 The ambient temperature around UPS should keep in...

Страница 11: ...9 4 4 UPS output connection Fig 6 output connection 4 5 Long backup external battery connection Fig 7 battery connection...

Страница 12: ...intercross as following Figure Fig 8 RT 1250VA S H plastic base assembly RT 2000VA RT 3000VA S H plastic base assembly is similar to RT 1250VA S H the difference is that there is a 1U plastic base br...

Страница 13: ...mbly cabinet installation bracket screw hole A screw hole B are respectively corresponding to two screws symmetrical on both sides a total of four Fig 11 Cabinet installation bracket Fig 12 Cabinet in...

Страница 14: ...l battery It is best to use external battery cable which matches with the equipment When connecting load to UPS first turn off load and then connect the power cable and finally turn on load one by one...

Страница 15: ...on Press and hold the key for more than 1 second in battery mode UPS runs the mute function INQUIRING key or Non functional setting mode Press and hold the key for more than half a second less than 2...

Страница 16: ...ter green LED is on UPS is normally powered by mains or ECO mode or battery mode After starting the UPS the four LEDs will light and go out one by one It circulates several times until starting the UP...

Страница 17: ...the capacity of the battery and load Every pane represents 20 capacity As graphics showed above the capacity of the battery is 80 100 5 panes the load reaches 40 60 3 panes When UPS is overload the ic...

Страница 18: ...n LED will light and go out circularly and orderly When self test finishes it will come to line mode the corresponding LED lights UPS is working in line mode Turn on the UPS by DC without mains power...

Страница 19: ...hen meets some standards The set information can be saved only when the battery connected and normally turning off the UPS The operation of setting is as following 5 3 1 ECO mode setting Enter the set...

Страница 20: ...hold function setting key for more than 2 seconds exit from the setting interface and turn to main interface 5 3 2 Bypass output setting Enter the setting interface Press and hold the function settin...

Страница 21: ...2 seconds Now the bPS setting function is completed and the ON or OFF below the bPS will light without flash Exit from the setting interface Press and hold function setting key for more than 2 seconds...

Страница 22: ...conds select the numerical value in accordance with OPU function The provided voltages are 208v 220v 230v 240v you can choose anyone by yourself The default is 220v Confirm the output voltage setting...

Страница 23: ...Display the output voltage and output frequency of the UPS As the following graphic shows the output voltage is 220v the output frequency is 50Hz Load Display the numerical value of the active power W...

Страница 24: ...put voltage is 210v input frequency is 49 8Hz Battery Display the voltage and capacity of the battery determined by type As the following graphics shows the battery voltage is 28v the capacity of batt...

Страница 25: ...ne mode NOTE When UPS is working in bypass mode it has no back up function 5 5 2 Line mode LED indications on front panel in line mode are as following the inverter green LED is on When input AC mains...

Страница 26: ...ad fault inverting fault and over temperature fault happen UPS cuts off the output and LCD display fault codes At the moment you can press the mute key to make the buzzer stop beeping temporarily to w...

Страница 27: ...a batteries should be manually charged and discharged once every two months The process is the same as that said above 3 Under normal circumstances of using the battery working life is three to five y...

Страница 28: ...to if beeps for a long time it means that there is something wrong with the machine 3 If you need help contact our service department the following messages should be provided for analysis UPS MODEL N...

Страница 29: ...onds Affirm if the battery switch is closed Inverting mode Once every four seconds Affirm if the battery switch is closed Power up or start Six times Affirm if the battery is connected well 5 Output o...

Страница 30: ...apacity indicator flashes Battery low voltage or battery disconnected Check UPS battery connect battery well if battery damaged replace it Mains normal but UPS has no input UPS input breaker open circ...

Страница 31: ...208 220 230 240VAC Power factor 0 8 Voltage precision 2 Output Fre quency Line mode 1 When input frequency is in the range the output frequency is the same as that of input 2 When input frequency is...

Страница 32: ...g the rated output voltage by LCD menu is an optional Work Environment Model RT 1250VA S H RT 2000VA S H RT 3000VA S H series Temperature 0 40 Relative humidity 0 95 non condensing Altitude 1500m when...

Страница 33: ...intelligent USB card intelligent SNMP card and intelligent dry contact card Support the hot plug and play Any card of them can be used according to users requirements a Intelligent USB card Use the mo...

Страница 34: ......

Страница 35: ......

Отзывы: