Operating Instructions
9
1.
Install piping as shown in Figure 4. Refer to Figure 5 for recommended, closed loop installation.
2. Make sure any tube, pipe or hose connected to the unit can withstand operating temperatures and retain
pressure.
1.
Install appropriate ASME code safety valves and adequate condensate drains on piping system.
2. Never use reducers in discharge piping. Keep all piping and fittings the same size in the piping system to
help prevent pressure drops
Never use plastic (PVC) pipe for compressed air. Serious injury or
death could result.
Installing
WARNING
Minimum Pipe Size For Compressed Air Lines
(Pipe size shown in inches)
SCFM
20
40
60
100
125
150
200
25 ft.
3/4
3/4
3/4
1
1-1/4
1-1/2
2
50 ft.
3/4
1
1
1
1-1/4
2
2
100 ft.
3/4
1
1
1
1-1/2
2
2
250 ft.
1
1
1
1-1/4
1-1/2
2
2