Operating Instructions
29
1.
If the machine is stopped for over
three weeks:
a) Wrap electrical equipment such as the control panel with plastic or oil paper to avoid condensation.
b) Completely drain water in the oil cooler, the back cooler and the oil/air separator tank.
c) Make sure any unsafe conditions are clearly stated or repaired.
2.
If the machine is not run for more than
two months:
a) Seal all ports to prevent moisture or dust accumulation.
b) Wrap safety valve & control panel with oil paper or an equivalent to avoid rust.
c) Replace lubricating oil then run machine for 30 minutes. Drain condensed water in the oil/air
separator tank and the oil cooler 2-3 days later.
d) Move machine to a clean, dry place.
1.
Remove any wrappings from system components.
2.
Ensure electric motor is properly insulated.
3.
Perform initial checks then follow procedures for start up.
Storage
Restarting Procedure
Safety Steps
Maintenance
To avoid shock and serious personal injury, disconnect, tag and lock
out power source then release all pressure from the system before
attempting to install, service, relocate or perform ANY maintenance.
To avoid serious personal injury, when performing service in any
enclosure large enough to hold a man, inform others then be sure
to tag and keep open any access doors. Before closing and latching
access doors, make sure all persons are clear from enclosure.
WARNING