Operating conditions

 This product is an 

U

ninterruptible

P

ower 

S

upply (

UPS

) for computers

and their peripherals, television sets,
stereo systems and video recorders...
It must not be used to supply other
electrical equipment (lighting, heating,
household appliances, etc.).

UPS connections

 Connect the 

UPS 

1

 to the AC-

power system via a wall outlet with an
earth connector (see figure A).

 Plug critical equipment (computer,

monitor, modem, etc.) into the outlets

8

 providing battery backup power

and surge protection (see figure B),
taking care not to exceed the rated
current indicated in amperes.

 Other devices (printer, scanner, fax,

etc.) can be connect to the filtered
outlets 

7

 that provide surge

protection (see figure B). The filtered
outlets are not backed up by battery
power in the event of a power outage.

 

Optional fax/modem connection:

A telephone, fax, modem or Ethernet
data line can be protected against
surges by connecting it to the
telephone outlet via the 

UPS

. The

device cable is used between the
telephone outlet and the 

UPS

, and the

supplied cable 

2

 is used between

the 

UPS

 and the device, as indicated

in figure C.

 

Optional COM connection:

The 

650

 and 

800 VA

 devices can be

connected to the computer using the
special USB cable 

5

 supplied.

The software available on the CD-
ROM 

6

 (or downloadable from the

eaton.com site) can be configured to
monitor the UPS and the supply of
power to the computer (see figures D
and F).

 Follow the indicated procedure.

Operation

7

 : Four filtered outlets.

8

 : Four battery backup outlets.

9

 : LED ON indicate that surge

protection is active on all eight
outlets.

10

: LED ON indicate a 

UPS

 fault.

11

: ON/OFF button for the battery

backup outlets.

12

: Protection circuit breaker.

 

Battery charge:

 The 

UPS

 charges

the battery as soon as it is connected
to the AC outlet, whether button 

11

 is

pressed or not. When used for the first
time, the battery will only provide its
maximum autonomy after it has been
charged for 8 hours. It is
recommended that the 

UPS

 be

permanently connected to the AC
power supply to ensure the best
possible autonomy.

 

Filtered outlets 

7

 without battery

backup:

 Equipment connected to

these outlets is supplied as soon as
the AC cord is plugged in. They are
not affected by button 

11

.

 

Battery backup outlets 

8

:

Equipment connected to these outlets
is supplied as soon as button 

11

 is

pressed and turns green (see figure
E). These outlets can be turned on
even if the 

UPS

 is not connected to

AC power (button 

11

flashes).

 

AC-power disturbance:

 If AC

power is disturbed or fails, the 

UPS

continues to operate on battery power.
Button 

11

flashes green. In normal

mode, the audio alarm beeps every 5
seconds, then every 2 seconds when
the end of battery backup time is near.
In silent mode (see the section on
customizing), the audio alarm simply
beeps once when the 

UPS

 transfers

to battery power.

 If the power outage lasts longer than

the battery backup time, the 

UPS

shuts down and automatically restarts
when power is restored. Following a
complete discharge, a few hours are
required to recharge the battery back
to full backup time.

 To save battery power, it is possible

to press button 

11

to cut the supply of

power to the devices connected to the
battery backup outlets.

 ◗

 

Surge protection:

 All outlets,

whether backed up or simply filtered,
include surge protection, whatever the
position of button 

11

.

 

Shutdown of the battery backup

outlets 

8

:

 Press button 

11

for more

than two seconds.

Master and EcoControl
outlets operating procedure:

In order to limit energy consumption of
peripherals (scanner, printer) in
standby mode, the 

Protection

Station

 is equipped with 

EcoControl

outlets that are dependent on the

Master 

(see figure B) outlet. When

the main application supplied by the

Master 

outlet (computer) is shut

down, the 

EcoControl 

outlets are

automatically deactivated and the
peripherals shut down.
This function (deactivated by default)
is validated and configured using the
configuration tool integrated in the

Solution-Pac

 (software supplied with

your 

Protection Station

).

Note:

 When the function is activated,

do not connect critical applications to

EcoControl 

outlets.

Threshold setup:

A default setup ensures the correct
operation of the 

EcoControl 

function.

However, depending on the
consumption of the main load, the
trigger threshold of the 

EcoControl

function may have to be modified
using the configuration software
supplied with the 

UPS

:

 First, make sure that the function is

activated in the “

EcoControl

Function

“ tab of the configuration

tool.

 If the peripherals connected to the

EcoControl 

outlets do not switch off

when the main load is not in normal
operation (ex: when in standby mode),
the detection threshold value must be
set to 

High

.

 If the rated consumption level of the

main load is low and the 

EcoControl

outlets shut down when the main load
is operating normally, the detection
threshold value must be set to 

Low

.

10

11

9

8

12

7

Содержание Protection Station 800

Страница 1: ...MAU 00075 AA Installation and user manual English Français Deutsch Italiano Español Nederlands Português Polski Finnish Protection Station 650 800 ...

Страница 2: ...urezza riportate sul libretto 3 In seguito attenersi alle istruzioni riportate sul presente manuale 4 Antes de la instalación del Protection Station leer el manual 3 que presenta las instrucciones de seguridad a cumplir A continuación seguir las instrucciones del presente manual 4 Lees voordat u het Protection Station gaat installeren eerst de veiligheidsinstructies in boekje 3 Volg daarna de inst...

Страница 3: ...MAU 00075 AB 3 Quick start A B Internet modem fax 2 C Product representations not legally binding F E OK OK 1s Beep D 5 ...

Страница 4: ...essed and turns green see figure E These outlets can be turned on even if the UPS is not connected to AC power button 11 flashes AC power disturbance If AC power is disturbed or fails the UPS continues to operate on battery power Button 11 flashes green In normal mode the audio alarm beeps every 5 seconds then every 2 seconds when the end of battery backup time is near In silent mode see the secti...

Страница 5: ...f electrocution with a new battery approved by Eaton to ensure correct operation of the UPS The battery must be disposed of in accordance with applicable regulations To remove the battery shut down the UPS button 11 OFF remove the power cord and proceed as indicated below Battery change Warning take care not to inverse the polarity red and black when connecting the batteries as this will destroy t...

Страница 6: ...utton Have the electrical installation checked by a professional or use another wall outlet Disconnect excess equipment connected to the battery backup outlets 8 Call after sales support Call after sales support Disconnect the telephone line from the wall outlet Call after sales support Have the battery replaced 1 2 3 4 5 6 7 8 9 10 Advanced customizing of your UPS Sensitivity to variations of the...

Страница 7: ...MAU 00075 AB 28 POLSKI 10 11 9 8 12 7 ...

Страница 8: ...MAU 00075 AB 29 POLSKI G H I J ...

Страница 9: ...MAU 00075 AB 30 ...

Страница 10: ...le to 161 V 284 V 50 60 Hz 46 70 Hz working range 220 V 230 V 240V 7 50 60 Hz 1 Hz with pseudosinusoidal wave 10 A max 0 5 mA 10 A resettable circuit breaker 5 ms typical Tel ISDN ADSL Ethernet Once a week 4 years typical depending on number of discharge cycles and temperature 0 to 35 C 25 C to 55 C 0 to 85 0 to 3000 m IEC 60950 1 IEC 62040 1 1 CE certified IEC 62040 2 2 years 2 8 A max 3 5 A max ...