4.5.8 Manufacturer-specific objects on DC1 devices
In addition to communication-specific objects, manufacturer-specific objects
are also defined in the object dictionary. These objects fall within the range
between index 2000
hex
and index 2096
hex
in the DC1 variable frequency
drive‘s object dictionary.
Table 17: Manufacturer-specific objects
Index
[hex]
Object Name
Description
Access
right
Data type
2000
Control command register
Command
rw
UNSIGNED16
2001
Speed reference
Frequency reference value
rw
Integer16
2003
User ramp reference
User ramp time
rw
UNSIGNED16
200 A
Drive status register
status word
ro
UNSIGNED16
200B
Motor speed Hz
Actual value in Hertz (Hz)
ro
UNSIGNED16
200D
Motor current
Motor Current
ro
UNSIGNED16
2010
Drive temperature
variable frequency drive
temperature
ro
Integer 16
2011
DC bus value
DC Link Voltage
ro
UNSIGNED16
2012
Digital input status
State of digital inputs
ro
UNSIGNED16
2013
Analog input 1 (%)
Analog input 1 in %
ro
UNSIGNED16
2014
Analog input 2 (%)
Analog input 2 in %
ro
UNSIGNED16
2015
Analog input 1
Analog Input 1
ro
UNSIGNED16
2017
Relay output 1
Relay output 1
ro
UNSIGNED16
203E
Total run hours
Operating time in hours
ro
UNSIGNED16
203F
Total run minute/second
Operating time in
minutes/seconds
ro
UNSIGNED16
2040
Current run hours
Current operating time in hours
ro
UNSIGNED16
2041
Current run minute/second
Current operating time
in minutes/seconds
ro
UNSIGNED16