![Eaton Night Falcon/UFLD Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/eaton/night-falcon-ufld/night-falcon-ufld_installation-instructions-manual_3795330002.webp)
2
EATON
IB506007EN
Installation instructions
Installation Instructions – Night Falcon/UFLD
INSTALLATION
Tools Required
Ratchet, 3/4" socket, 3/8" square nut driver, 9/16" wrench,
and #2 Philips screwdriver.
Trunnion Mounting (Figure 1.)
1. Mount luminaire to surface using the hole pattern
provided on the trunnion bracket.
2. Loosen but do not remove (2) center bolts and (1) set
screw.
3. Rotate luminaire to desired aiming position and tighten
center bolts to 10ft-lbs.
4. Tighten set screw to 30 in-lbs.
5. Refer to wiring diagrams for power connection.
(Figure 4.)
Slipfitter Mounting (Figure 2.)
1. Fixture is pre-set at 45 degree tilt. If angle adjustment
is required please proceed to step 2, if not skip to
step 5.
2. Remove (2) cover plate screws and cover plate with #2
Philips screwdriver.
3. To change luminaire tilt angle, loosen center bolt, rotate
fixture to the desired angle, and tighten center bolt to
30 ft-lbs.
4. Replace cover plate and tighten cover plate screws with
#2 Philips screwdriver to 15 in-lbs.
5. Make wiring connections per wiring diagram and place
connections down into pole or mounting bracket.
(Figure 4.)
6. Loosen (3) set screws and slide the slipfitter onto pole
or mounting bracket.
7. Position luminaire into the desired direction; and tighten
(3) set screws to 10 ft-lbs.
8. Tighten lock nuts to 15 ft-lbs.
Figure 1.
Set Screw
(2) 9/16”[14mm]
9-1/8” [232mm]
(2) 7/16”[11mm]
3-3/4”
[95mm]
2” [51mm]
7/8” [22mm]
Trunnion Mount Drill Pattern
2”[51mm]
Center Bolt
Trunnion
Bracket
Figure 2.
Center Bolt
Lock Nut
Pole
Coverplate
Coverplate
Screws (2)
Set Screws