Installation Instructions – Define S122-125 Suspended LED Luminaire
Installation Instructions – Define S122-125 DP/RDP/DIP/RDIP
IL524025EN www.eaton.com
INSTALLATION
Define DP/RDP/DIP/RDIP
(2”- 5” Housing Size)
Individual and Continuous Luminaires - Installation
Turn off power before installation. Connect mounting kits at pre-
specified locations according to your specific ceiling type (see
submittal for dimensional details). Remove fixture from box and
remove access plate by removing four #8-32 screws.
Pull aircraft cable through griplocks
®
and adjust to desired
height. Make sure to level the fixture correctly (applies to
individuals or first piece in row).
Parts List
•
Fixture
•
Access Plate
•
Push In Connectors
•
Cast Joiner & Torx Screws
•
Additional 8-32 Phillips Screws
•
Phillips Screw Driver (Bit)
•
6L – T15 Torx Screwdriver (Bit)
•
Rubber Mallet
•
T-15 Torx Joining Screws (2 per row
fixture connection)
•
#8-32
Joining Bracket Screws (2 per
row fixture connection)
Cross Section and Grid Spacing Details
W
X
Y
V
1
2
DP/RDP/DIP/RDIP
All Grid
V (Flush)
W (Regressed)
X
Y
Define 2
4.132
5.132
2.000
1.680
Define 3
4.567
5.567
3.000
2.680
Define 4
5.132
6.132
4.000
3.680
Define 5
5.632
6.632
5.000
4.680