Installer Menu Map
Page 34
On Time
1 second
Exp. W1-nn
EDIT
output
Name
Type
Not used
Polarity
Normal
Pulsed
No
Partitions
All outputs allocated to all
Partitions
Visible only in a partitioned system.
Zones
None
Delay
0 seconds
Visible
when Pulsed set to “Yes”.
On Time
1 second
Keypad k1-nn
EDIT
output
Visible only when a suitable keypad is
fitted.
Name
Type
Not used
Polarity
Normal
Pulsed
No
Partitions
All outputs allocated to all
Partitions
Visible only in a partitioned system.
Zones
None
Delay
0 seconds
Visible
when Pulsed set to “Yes”.
On Time
1 second
Plug-by
outputs
EDIT PLUG-BY
O/P1...
Name
Type
O/P1: Fire Alarm
O/P2: Hold Up Alarm
O/P3: Burglar Alarm
O/P4: Open / Close
O/P5: Zone Omit (System)
O/P6: Tamper
O/P7: Confirmed Alarm
O/P8: General Fault
O/P9: AC Fail
O/P10: Battery Fault
O/P11: Technical Alarm
O/P12: Alarm Abort
Polarity
Normal
Pulsed
No
Partitions
All outputs allocated to all
Partitions.
Visible only in a partitioned system.
Zones
None
Delay
0 seconds
Visible
when Pulsed set to “Yes”.
On Time
1 second
Custom
Outputs
Custom Output 1...
Mode
Any (Or)
Inputs
None
3 Setting options (only shown in a part-setting system)
Appears only in a part-setting system.
Full Set
Name
“Full Set”
Exit Mode
Timed Set
Settle Time
15 seconds
Visible
only if Exit Mode is “Final Door”,
“Lock Set” or “Exit Terminate”.
Exit Time
40 seconds
Visible
only if Exit Mode is “Timed Set”
or “Silent Set”.
Entry Time
40 seconds
Siren Delay
0 minutes
Siren Time
15 minutes
Strobe on Set
Off
Strobe on Unset
Off
Part Set B/C/D
Name
“Part Set B”
Exit Mode
Instant Set
Settle Time
15 seconds
Visible
only if Exit Mode is “Final Door”,
“Lock Set” or “Exit Terminate”.
Exit Time
40 seconds
Visible only if
Exit Mode is “Timed Set”
or “Silent Set”.
Entry Time
40 seconds
Alarm Response
Siren
Siren Delay
0 minutes