7
Digital Switch Wiring
ControlKeeper® 4A
powering a number of these devices. Please refer to the
chart below for details on how many devices the transformer
can support.
Greengate
PIR
Sensor
Greengate
Dual-Tech
Sensor
Greengate
Ultrasonic
Sensor
PPS-4
Indoor
Photosensor
PPS-5
Outdoor
Photosensor
40
16
20
20
4
Please contact technical support if it is necessary to power
additional sensors beyond the numbers listed above.
These figures do not account for additional devices such
as lighted switches or digita switches being used. If using
a combination of devices, please contact technical support
for exact details on how many devices the logic panel can
power.
Figure 11: Photosensor and Motion Sensor Wiring
Digital Switch Wiring
Each ControlKeeper 4A panel is capable of supporting up to
7 Digital Switch device stations and 1 GDS-I gateway device
(the number the controller is able to support is dependent on
the number of other low voltage devices wired that require
power from our logic board. Please contact Technical Support
for exact details of how many devices your logic board can
power.)
Digital Switch cable type should be Eaton’s Cooper LC Cable,
Belden 1502R (non-plenum), or Belden 1502P (plenum).
For best network performance, one of the suggested cables
should be used. If the specified cable is not used and
communications problems occur that require troubleshooting
assistance, additional charges for support may be assessed.
Digital Switches do not wire directly to the ControlKeeper 4A
panel, but are wired to a CAN Bus network that connects to
the ControlKeeper 4A through a GDS-I device. Digital Switch
devices should be networked together in a daisy chain
configuration. No T-Taps/Stars should be used.
The GDS-I device should reside somewhere within the
daisy chain switch network. Total daisy chain network length
should not exceed 1000 feet
The following instructions describe the GDS-I device
connection to the ControlKeeper 4A. Please refer to the
Digital Switch Installation Instructions for information on
wiring the Digital Switch network to the GDS-I device.
1. Mount the GDS-I next to the ControlKeeper 4A panel.
A six foot phone style cable has been provided for
connection to the ControlKeeper 4A panel.
2. Run a length of the Digital Switch LC or Belden cabling
from the GDS-I location to the low voltage section of
the ControlKeeper 4A.
3. Connect the RED wire in the cable to the +V terminal
on the back of the GDS-I and to the ControlKeeper 4A
remote power con24 V terminals.
4. Connect the BLACK wire in the cable to the GND
terminal on the back of the GDS-I and to the
ControlKeeper 4A remote power connector GND
terminal.
5. Tape back or cap the blue and white wires and shield
wire for the cable. They will not be used for connection
between the GDS-I and lighting controller.
6. Locate the 6 foot phone style cable included in the
GDS-I box. Run this from the GDS-I into the low voltage
section of the ControlKeeper 4A enclosure plugging the
end with 9 pin head into the GDS-I. Plug the end the
RJ11 phone style plug into the ControlKeeper 4A.
PCI-NET TERM
REMOTE
LOCAL
50-022510-02
54-022510-
+24 GND
RS-232
PCI-NE
T
PCI-NE
T
ANALOG INPUTS
ANALOG COM
NETWORK
ALL ON
ALL OFF
POWER
RSC STAT
SWIN STAT
CAN-TX
CAN-RX
RESET PICS
LSO TEST
+24
+24
+24
+24
IN
IN
IN
IN
IN
IN
IN
IN
1
2
3
4
5
6
7
8
LS
LS
LS
LS
1
2
3
4
AN AN AN AN
1
2
3 4
DIMMING OUTPUTS
SWITCH INPUTS
VIO
1
2
3
4
GRY
1
2
3
4
ADDRESS
+NE
T-
NE
T
VIO
GRY
VIO
GRY
VIO
GRY
U2
SC1
TB7
SR1
L1
C20
PS1
L2
U20
U19
U12
TB5
U15
U16
TB4
U6
J2
J3
U7
U11
U10
U9
U1
J4
J1
J6
TB1
LED1
U5
U14
U13
TB3
S1
BR1
C39
C48
C47
C49
C40
J7
J8
REG2
REG1
SR2
TB2
J5
LED2
LED3
SW1
U8
H1
TB6
REG3
TP1
U18
U17
LED6
C29
LED7
LED5
LED4
L1 L2 L3 L4
SW3
SW2
SW1
Reset
1 2 3
4
5 6
7
8
Q4
Q3
Q2
Q1
LED9
K1
K2
K3
K4
MOV1
MOV3
MOV2
MOV4
TB1
TB2
TB3
TB4
LED1
LED3
LED5
LED7
U3
U2
U1
SW1
SW2
SW3
SW4
U4
PCI 2005
C
X4 SR
C
ST
AT
US
50-022110-01
LINE
LO
AD
LINE
LO
AD
LINE
LO
AD
Figure 12: Digital Switch Gateway Wiring Detail
Local Remote Jumpers
Moved to Local Position
(Jumper Over Top Pins)
Wire Phone Style Cable to RJ11
Jack on CK4A and to GDS-1
BLACK Wire From GDS-1
GND to CK2 GND
RED Wire From GDS-1 V+
to CK2 +24 VDC
Cabling is EAton’s Cooper LC Cable, Belden 1502R, or Belden 1502P
GDS-I
Contact Input
Photosensor
Wiring
Typical Greengate
Motion Sensor Wiring
Local Remote
Jumpers in
Local Position
PPS4
PPS5
ON/IN
(Blue Wire)
ON/IN
(Blue Wire)
ON/IN
(White Wire)
Black
Black
Black
+24 VDC
(Red Wire)
+24 VDC
(Red Wire)
Yellow & White
Wires Not Used
+24 VDC
(Red Wire)
REM
PWR
DC
GND
(Blac
k
W
ire)
Содержание Greengate ControlKeeper CK4A-SLRC
Страница 33: ......