3. Operation

3.1  Start-Up and Normal Operation

 

For the initial start-up, AC power must be present to detect any wiring errors. After inital start-up, the UPS can  

  start even if AC power is not present.

UPS personalization

  

If UPS personalization is desired, it is advised to enter the personalization mode at this time.

This mode may be entered using the buttons on the control panel or the 

Personal Solution-Pac

 Software (Windows) 

included on the 

Solution-Pac

 CD-ROM provided by EATON.

Press button 

(27)

 for approximately 1 second.

 

w

  The buzzer beeps once and all the LEDs go 

ON simultaneously.

 

w

  The buzzer then beeps twice during the 

self-test, then button 

(27)

 remains ON, 

indicating power to the output receptacles.

 

  The connected devices are protected by 

the UPS.

 

w

  LED 

(20)

 is ON.

 

  If LED 

(22)

 is ON, a fault has occurred (see 

the “Troubleshooting” section).

 

w

  During normal operation, the scroll 

button 

(25)

 may be used to read UPS 

measurements (voltage on normal and 

bypass AC inputs, operating mode, battery 

capacity and UPS serial number).

86-86710-00EN A02 - Page 17

86-86710-00 A02 UM.indd   17

14/01/2009   10:56:26

(このページは空白です)

Содержание EX Pulsar Series

Страница 1: ...ion and User Manual English EX 2200 RT 2U 3000 RT 2U EXB RT 3U Pulsar Series 86 86710 00 A02 UM indd 1 14 01 2009 10 56 17 Installation and User Manual EX 2200 RT 2U 3000 RT 2U EXB RT 3U Pulsar Series...

Страница 2: ...w P 86 86710 00...

Страница 3: ...nglish EX 2200 RT 2U 3000 RT 2U EXB RT 3U Pulsar Series 86 86710 00 A02 UM indd 1 14 01 2009 10 56 17 EX 2200 RT 2U 3000 RT 2U EXB RT 3U Pulsar Series www eaton com 2010 EATON Email JapanSales Eaton c...

Страница 4: ......

Страница 5: ...2 6 1 3 6 2 2 1 7 2 2 8 2 3 8 2 4 9 2 5 FlexPDU 10 2 6 MBP 10 2 7 FlexPDU MBP UPS 11 3 3 1 13 3 2 14 3 3 AC 14 3 4 UPS 14 3 5 UPS 15 4 4 1 17 4 2 17 4 3 17 4 4 18 5 5 1 19 5 2 20 5 3 MBP UPS 22 6 6 1...

Страница 6: ......

Страница 7: ...1 EATON EX VCCI A III IV UPS EATON EX www eaton com EATON UPS EATON CFC HCFC 50 PS PET 01 HDPE 02 PVC 03 LDPE 04 PP 05 PS 06 www eaton com 01 PET 01 PET...

Страница 8: ...A VCCI 2008 04 Class A EN 62040 2 IEC 62040 2 IEC 61000 4 2 ESD IEC 61000 4 3 Radiated eld IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEEE C6241 Category B Ring wave IEC 61000 4 6 Electromagnetic eld IEC...

Страница 9: ...3 LED LED LED CFC HCFC UPS EATON EATON UPS EATON UPS...

Страница 10: ...4...

Страница 11: ...56 20 1 Presentation 1 1 Standard Positions Tower Position Rack Position Dimensions H x W x D in inches EX 2200 RT 2U 17 3 x 3 38 x 25 2 EX 3000 RT 2U 17 3 x 3 38 x 25 2 EX EXB RT 3U 17 3 x 5 16 x 19...

Страница 12: ...onnection of equipment 10 10 foot input power cord w L5 30P for EX 3000 w 5 20P for EX 2200 11 LED SWF indicating distribution system phase neutral reversal 12 Connectors for battery modules to the UP...

Страница 13: ...ions cable 34 USB communications cable 36 Solution Pac CD ROM 37 Documentations supplied depending on the UPS model 38 Mounting kit for 19 inch bays 39 2 supports for the upright position 40 FlexPDU m...

Страница 14: ...y EATON 86 86710 00EN A02 Page 12 2 Installation 86 86710 00 A02 UM indd 12 14 01 2009 10 56 22 2 2 Installation in Tower Position 2 3 Installation in Rack Position It is advised to first install the...

Страница 15: ...ot restricted access 86 86710 00EN A02 Page 13 2 Installation 86 86710 00 A02 UM indd 13 14 01 2009 10 56 23 2 4 Communication Ports Connection of RS232 or USB communication port optional The RS232 an...

Страница 16: ...PDU 2 6 MBP MBP UPS 2 5 Connections with a FlexPDU Power Distribution Unit Module optional 2 6 Connections with a HotSwap MBP Module optional The HotSwap MBP module makes it possible to service or eve...

Страница 17: ...UPS start up with the HotSwap MBP module 1 Check that the UPS is correctly connected to the HotSwap MBP module 2 Set switch 53 to the Normal position 3 Start the UPS by pressing the ON OFF button 27 o...

Страница 18: ...12 86 86710...

Страница 19: ...ncluded on the Solution Pac CD ROM provided by EATON Press button 27 for approximately 1 second w The buzzer beeps once and all the LEDs go ON simultaneously w The buzzer then beeps twice during the s...

Страница 20: ...The devices connected to the UPS are no longer supplied w The connected devices continue to be supplied by the UPS when AC power is no longer available The necessary energy is provided by the battery...

Страница 21: ...009 10 56 28 3 5 UPS EX 2 RPO Remote Power Off UPS UPS 27 ROO Remote On Off AC 27 UPS UPS 5 3 5 Using the UPS Remote Control Functions EX has the choice of two remote control options w RPO Remote Powe...

Страница 22: ...16...

Страница 23: ...m Enabled Disabled w Press the Scroll button 25 several times until the personalization menu is reached w Press the Enter button 26 to access the different possibilities w Finally confirm the selectio...

Страница 24: ...C 1 2 1 1 50 60 Hz AC 1 AC AC 1 102 50 70 AC UPS 5 SWF UPS 0 200A AC UPS EATON 4 4 Solution PacCD ROM PC Point to Point solution Personal Solution Pac Settings Advanced Settings UPS Settings Personal...

Страница 25: ...LCD BATTERY FAULT SERV REQUIRED 5 2 5 LED 21 LCD OVERLOAD ALARM REDUCE LOAD UPS 6 LED 22 LCD LOAD UNPROTECTED OUTPUT OVERLOAD UPS UPS AC UPS 7 LED 22 LCD REDUCE LOAD RESTART UPS UPS UPS Bypass UPS AC...

Страница 26: ...20 MBP UPS 12 MBP 53 Bypass MBP UPS AC MBP UPS UPS MBP 2 6 13 MBP 53 Normal UPS UPS MBP UPS UPS MBP 2 6 14 AC MBP 53 Bypass UPS MBP MBP 53 Normal UPS MBP 2 6 UPS UPS 27 5 2 a b c d e f 5 86 86710...

Страница 27: ...s together the two parts of the connector during remounting A Unscrew the left hand side of the front panel two screws then remove the part B Disconnect the battery block by separating the two connect...

Страница 28: ...d replaced Return to normal operation 1 Check that the UPS is correctly connected to the HotSwap MBP module 2 Start the UPS by pressing the ON OFF button 27 on the UPS control panel LED 51 UPS ON OK t...

Страница 29: ...V 4 50 60 Hz autoselection 0 95 2 mA Load output w Voltage w Frequency w Harmonic distortion w Overload capacity w Current 100V 50 60 Hz 0 5 6 4 for linear load 6 for nonlinear load 102 continuous 105...

Страница 30: ...r to 0 to have powershare outlet provide power at the same time the as main outlets 86 86710 00EN A02 Page 28 6 Appendices 86 86710 00 A02 UM indd 28 14 01 2009 10 56 32 6 2 Programming the Programmab...

Страница 31: ...pply button The section entitled Shutdown timer allows the user to define how long the powershare outlet should provide power after a power loss To configure the powershare to power off at the same ti...

Страница 32: ...6 6 3 AC AC UPS UPS UPS UPS UPS FlexPDU Power Distribution Unit UPS AC 50 Hz 60 Hz 60 Hz 50 Hz MBP UPS LCD AC UPS AC UPS UPS Personal Solution Pac UPS Personal Solution Pac UPS AC UPS UPS UPS UPS UPS...

Страница 33: ...www eaton com 86 86710 00 A02 86 86710 00 A02 UM indd 34 14 01 2009 10 56 53 www eaton com...

Страница 34: ...w P 86 86710 00...

Страница 35: ...A02 UM indd 1 14 01 2009 10 56 17 Installation and User Manual EX 2200 RT 2U 3000 RT 2U EXB RT 3U Pulsar Series www eaton com Copyright 2010 EATON All rights reserved For Technical Support Customer Ca...

Страница 36: ......

Страница 37: ...on 3 1 Start Up and Normal Operation 13 3 2 Operation on Battery Power 14 3 3 Return of AC Power 14 3 4 UPS Shutdown 14 3 5 Using the UPS Remote Control Functions 15 4 Access to Maintenance and Person...

Страница 38: ......

Страница 39: ...asbestos Packing To improve waste treatment and facilitate recycling separate the various packing components The cardboard we use comprises over 50 of recycled cardboard Sacks and bags are made of pol...

Страница 40: ...ield IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEEE C6241 Category B Ring wave IEC 61000 4 6 Electromagnetic field IEC 61000 4 8 Conducted magnetic field This is a Class A product based on the standard of...

Страница 41: ...Important instructions that must always be followed Information advice help Visual indication Action Audible signal LED off LED on LED flashing 86 86710 00EN A02 Page 7 86 86710 00 A02 UM indd 7 14 01...

Страница 42: ...4 86 86710 00...

Страница 43: ...ht in pounds EX 2200 RT 2U 70 EX 3000 RT 2U 72 EX EXB RT 3U 93 Part Numbers EX 2200 RT 2U 86722 EX 3000 RT 2U 86732 EX EXB RT 3U 68405 86 86710 00EN A02 Page 9 86 86710 00 A02 UM indd 9 14 01 2009 10...

Страница 44: ...outlets for connection of equipment 9 Groups of 4 outlets for connection of equipment 10 10 foot input power cord w L5 30P for EX 3000 w 5 20P for EX 2200 11 LED SWF indicating distribution system ph...

Страница 45: ...o facilitate sorting 30 EX 2200 or 3000 UPS 33 RS232 communications cable 34 USB communications cable 36 Solution Pac CD ROM 37 Documentations supplied depending on the UPS model 38 Mounting kit for 1...

Страница 46: ...dvised to first install the battery module then the power module above Follow steps 1 to 4 for module mounting on the rails The rails and necessary hardware are supplied by EATON 86 86710 00EN A02 Pag...

Страница 47: ...ment 2 Connect the other end of the communica tion cable 33 or 34 to the USB 1 or RS232 2 communication port on the UPS The UPS can now communicate with EATON power management software It is not neces...

Страница 48: ...f the FlexPDU module EX 3000 EX 3000 1 Connect the input cord 56 of the HotSwap MBP module to the AC power source 2 Connect the UPS input cord 10 to the UPS Input 55 of the HotSwap MBP module This cor...

Страница 49: ...ed to the AC power source even if button 27 is not pressed Once the UPS is connected to the AC power source eight hours of charging are required before the battery can supply the rated backup time i T...

Страница 50: ...12 86 86710 00 This page left blank intentionally...

Страница 51: ...Solution Pac CD ROM provided by EATON Press button 27 for approximately 1 second w The buzzer beeps once and all the LEDs go ON simultaneously w The buzzer then beeps twice during the self test then b...

Страница 52: ...ately 2 seconds The devices connected to the UPS are no longer supplied w The connected devices continue to be supplied by the UPS when AC power is no longer available The necessary energy is provided...

Страница 53: ...a normally closed volt free contact 60 Vdc 30 Vac max 20 mA max 0 75 mm2 cable cross section between the two pins of connector 5 see diagram i RPO ROO 4 Plug connector 5 into the back of the UPS 5 Con...

Страница 54: ...16 4 4 4 86 86710 00 This page left blank intentionally...

Страница 55: ...o alarm Enabled Disabled w Press the Scroll button 25 several times until the personalization menu is reached w Press the Enter button 26 to access the different possibilities w Finally confirm the se...

Страница 56: ...ed Transfer to the bypass AC input 1 Bypass AC power must be within tolances Bypass AC power may be outside tolerances Overload level 1 102 50 70 Alarm if threshold is overrun Function Factory Setting...

Страница 57: ...UPS are fed directly by the electrical network via the By pass Check the power drawn by the connected devices and disconnect any non priority devices 7 LED 22 is ON the LCD indicates REDUCE LOAD REST...

Страница 58: ...y part of a grounded battery can result in electrical shock The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance applicable to equipment and remo...

Страница 59: ...to firmly press together the two parts of the connector during remounting A Unscrew the left hand side of the front panel two screws then remove the part B Disconnect the battery block by separating...

Страница 60: ...e UPS control panel LED 51 UPS ON OK to switch goes OFF the UPS can now be disconnected and replaced Return to normal operation 1 Check that the UPS is correctly connected to the HotSwap MBP module 2...

Страница 61: ...without condensation 20 40 C 4 104 F 1000 m w Noise level 47 dBA 86 86710 00EN A02 Page 27 86 86710 00 A02 UM indd 27 14 01 2009 10 56 31 EX 2200 EX 3000 EXB 9 Output power 1890 VA 1 1480 W 2500 VA 2...

Страница 62: ...power plug located in the SYS Tray 2 Click on the symbol next to UPS Settings to expand the UPS Settings section 3 Click on Startup Timer and change the The group of outlets restarts after to 0 to ha...

Страница 63: ...Shutdown timer allows the user to define how long the powershare outlet should provide power after a power loss To configure the powershare to power off at the same time as the main outlets 6 Set the...

Страница 64: ...ely drawn by the load to the maximum output of the UPS Personalization It is possible to modify certain UPS parameters set in the factory Certain UPS functions can also be modified by the Personal Sol...

Страница 65: ...es 31 2009 10 56 32 2009 10 56 32...

Страница 66: ...www eaton com 86 86710 00 A02 86 86710 00 A02 UM indd 34 14 01 2009 10 56 53 www eaton com 614 03760 01...

Отзывы: