You can't manage what you can't measure, and you certainly can't measure something you can't even see, without 
a power quality instrument that is. Invisible and fleeting power disturbances can be silent killers —the electronic 
equivalent of high blood pressure.

Eaton's Power Xpert 4000/6000/8000 meters represent a new genre of power quality instruments and world-class power 
monitoring that reduces day to day operating costs and helps avoid costly business interruptions. The meters combine 
state-of-the-art technology with next generation power diagnostics, data trending and performance benchmarking, 
along with a "Twist-n-Click" LCD graphic display: a new paradigm for simplicity and ease of use in the market place.

Features and Benefits

Applications

POWER xPERT

®

 000/000/000 METERS

Power Quality Metering Products

In addition the meters have an embedded web server that enables users to surf to the 

meter over the Internet via a standard web browser. The new platform offers advanced 

functionality like high speed impulsive transient waveform capture, 6Mhz sampling rate 

(6 samples every millionth of a second) with 1 millisecond time stamping, anti-aliasing, 

ITIC analysis and automatic trigger settings, open field upgradeable firmware, memory 

expandable to 1 GB and optional digital, relay I/O card.

•  Comprehensive power and power quality measurements for 138 standard data points logged
•  Embedded Web Server - see and analyze waveforms, trends, harmonics directly in your web browser/meter 

display

•  High speed 6 Mhz impulsive transient detection and waveform capture
•  Up to 1 millisecond time synchronization and event logging capability
•  Open protocol support: HTTP, Modbus TCP, Modbus RTU, SNMP, NTP, FTP, COMTRADE
•  Automatic trigger settings
•  Integrated ITIC analysis
•  Power Quality Health Index (ITIC, THD, TDD, dv/dt, Flicker) - 

Patent Pending

•  Alarm notification also available remotely via email (waveform attached)
•  512 MB/1 GB storage capability
•  Supported via Power Xpert

®

 software

•  ANSI C12.20 accuracy

Identify power quality problems

  • Identify harmonics, sags, swells and transients damaging or disrupting sensitive, mission critical IT equipment
  • Boost IT equipments service life to the maximum
  • Analyze sequence of events up to 1 millisecond time resolution
  • Protect motors from damage
  • Preserve the integrity of processes and batches
  • Prevent blown capacitor bank fuses
  • Protect transformers and conductors from overheating

Detect and record high speed transients

  • Avoid equipment damage and disruption
  • Identify equipment malfunction

Содержание E.T.N 1500 VA - 60kVa

Страница 1: ...Reference Guide Price Book Prices effective April 2008 500 VA 60 kVA...

Страница 2: ...ice Protection Systems to become the second largest single phase UPS manufacturer in the world The move resulted in an expanded product line and the addition of many new complementary offerings to our...

Страница 3: ...ngle phase Standby Powerware 3105 23 Series 5 Single phase Line interactive Powerware 5110 24 Powerware 5115 Tower 25 Powerware 5115 Rack 26 Powerware 5125 Tower 27 Powerware 5125 Rack Tower 1000 3000...

Страница 4: ...Plans 96 Powerware Three phase UPS Batteries 101 Input Plug and Output Receptacle Chart 102 Sales Returned Merchandise Authorization RMA Policy 103 Product Warranty Statements 104 Note Due to continu...

Страница 5: ...We will implement these changes in stages and will continuously send our partners rollout updates via e mail In addition the online version of the price book and reference guide on the UPS Salesweb wi...

Страница 6: ...for critical servers database servers networks and data centers Providing you with the most comprehensive level of protection we also recommend Series 9 for Network Area Storage NAS and Storage Area N...

Страница 7: ...ally damage hardware High frequency waveform Can be caused by either RFI or EMI caused by EMI interference interference generated by transmitters welding devices SCR driven printers lightning etc A ch...

Страница 8: ...Table 3 3 1 for systems operating at less than 69 kV less than 5 0 voltage total harmonic distortion THD and less than 3 0 individual harmonic voltage distortion Series 3 UPS The Series 3 UPS offers a...

Страница 9: ...the battery All Batteries Will Eventually Fail The question isn t Will it happen but When will it happen Because UPS batteries are valve regulated sealed lead acid there has previously been no practi...

Страница 10: ...he load The resulting neutral to ground voltage also causes parasitic ground currents e Additional losses resulting in higher energy costs f Failure of power factor correction capacitors or increased...

Страница 11: ...verload or unsafe condition now but the owner needs to be on guard against this harmonic threat Effects of Harmonics High levels of harmonics result in erratic or subtle malfunctions of equipment that...

Страница 12: ...hese reasons are so compelling that it s hardly worthwhile mentioning that all those features combined with our competitive pricing can lead to higher reseller margins Or is it Individual product warr...

Страница 13: ...Shipping List Description Part Number Pkg of H x W x D inches H x W x D inches Weight lb Price 42U x 1050D Sidewalls pair Black PWENC9970941 80 0 x 1 x 42 80 0 x 4 0 x 42 0 105 0 275 Casters Uninstall...

Страница 14: ...ons Shipping List Description Part Number Pkg of H x W x D inches H x W x D inches Weight lb Price Partition Wall for bayed enclosures PWACC9962621 1 77 0 x 40 0 80 0 x 42 0 x 4 0 10 0 300 Roof Mount...

Страница 15: ...L5 20 BA 15 5 20 24 60x2 1x1 3 169 PW102BA0U022 2 1 92 L5 20 BA 15 5 20 8 16x2 1x1 3 89 PW102BA0U023 2 1 92 L5 20 BA 15 5 20 10 24x2 1x1 3 89 PW103BA0U032 2 2 88 L5 30 BA 15 5 20 24 60x2 1x1 3 299 PW...

Страница 16: ...6 64x3 2x1 9 829 Horizontal Mount Models PW105ME1U048 2 4 99 L6 30 ME 10 IEC320 C19 4 1Ux19x4 3 399 PW105ME1U049 1 4 99 L6 30 ME 15 IEC320 C13 12 1Ux19x4 3 369 PW110ME1U083 2 9 98 IEC309 60 ME 10 IEC3...

Страница 17: ...nd a accessories port allows for temperature and humidity probes to manage local environmental conditions Vertical Mount 0U Models PW102SW0U150 2 1 92 L5 20 SW 9 5 15 8 42x1 89x2 779 PW102SW0U151 1 1...

Страница 18: ...5775 2 5 x 7 6 x 11 9 1 7 379 Environmental Rack Monitor C13 C14 100 250V AC 50 60Hz 3 pin power input 103005912 2 5 x 7 6 x 11 9 2 2 379 TH Module Black individual 103005822 2 4 x 6 3 x 8 8 0 7 79 En...

Страница 19: ...Customers connect directly to each panelboard main breaker Options List Price Input Connections Adders Direct Connection to Panelboard Main Breaker s Front Only Direct Connection to Panelboard Main Br...

Страница 20: ...rier Plate Front to Back for two separate sources 505 Extra knock out plates 165 Panelboard Isolated Ground Bus per Panel 100 SERVICE PLANS For service plans please see the service section beginning o...

Страница 21: ...08 15 1 2 Pole 3 12 awg 0 5 125 00 3 06 6 15R4 5662 208 15 1 2 Pole 3 12 awg 0 5 170 00 3 06 6 20R1 5465 208 20 1 2 Pole 3 12 awg 0 5 145 00 3 06 6 20R2 5462 208 20 1 2 Pole 3 12 awg 0 5 135 00 3 06 6...

Страница 22: ...120 15 1 1 Pole 4 12 awg 0 5 140 00 3 45 L5 20R1 IG 2310 120 20 1 1 Pole 4 12 awg 0 5 135 00 3 45 L5 30R1 IG 2610 120 30 1 1 Pole 4 10 awg 0 5 155 00 4 20 L6 15R1 IG 4560 208 15 2 2 Pole 4 12 awg 0 5...

Страница 23: ...205 00 10 30 9C33UO 250 30 2 2 Pole 3 10 awg 0 5 625 00 4 15 9C54U2 C75 250 50 3 3 Pole 4 8 awg 0 75 1 080 00 8 60 HBL360C6W 250 60 2 2 Pole 3 6 awg 0 75 1 050 00 10 30 HBL460C9W 250 60 3 3 Pole 4 6...

Страница 24: ...A 208 15 1 3 Pole 5 10 awg 0 5 365 00 4 75 FW360 N A 208 20 1 3 Pole 4 6 awg 0 75 140 00 13 15 FW360N N A 208 20 1 3 Pole 5 6 awg 1 00 270 00 15 30 FW3100 N A 208 20 1 3 Pole 4 3 awg 1 25 420 00 31 75...

Страница 25: ...Dimensions Weight List Model Number VA Watt Connection Receptacles H x W x D inches lb Price PW3105 500 103004247 5592 500 300 1 8 meter 8 5 15R Outlets 11 0 x 7 0 x 4 4 7 94 79 PW3105 700 103004248 5...

Страница 26: ...Dimensions Weight List Model Number VA Watt Connection Receptacles H x W x D inches lb Price PW5110 500 103004256 5591 500 300 1 8 meter 8 5 15R Outlets 10 6 x 3 4 x 10 2 12 1 120 PW5110 700 10300425...

Страница 27: ...x 13 2 27 8 448 PW5115 1400 05146566 5591 1400 950 5 15P 6 5 15R 15 1 x 5 9 x 15 4 37 0 554 1 Bundled with Software Suite CD and communication cable DB9f to DB9m P N 60420064 002 POWERWARE 5115 INTER...

Страница 28: ...on for a comprehensive list of IT enclosure offerings SOFTWARE AND CONNECTIVITY OPTIONS Bundled with Software Suite CD and communication cable See the software and connectivity product section for mor...

Страница 29: ...ODELS 230V 50 60 Hz includes 2 IEC interconnect cables Part Power Out Input Output Dimensions Weight List Model Number VA Watts Connection Receptacles H x W x D inches lb Price PW5125 1000i 05146630 5...

Страница 30: ...Watt Connection Receptacle H x W x D inches lb Price PW5125 1000i RM 05146667 6591 1000 900 IEC 320 C14 6 IEC 320 C13 3 5 2U x 17 0 x 19 4 61 0 810 PW5125 1500i RM 05146670 6591 1500 1340 IEC 320 C14...

Страница 31: ...for more detail SERVICE PLANS For service plans please see the service section beginning on page 88 POWERWARE 5125 RACK TOWER BATTERY BACKUP TIMES in minutes full load half load Load VA Standard Inter...

Страница 32: ...5125 6000 HW 103003610 5591 6000 5400 Hardwired Hardwired 5 25 3U x 17 50 x 26 0 161 0 3 258 4 C19 4 C13 PW5125 6000i 103003612 5591 6000 5400 IEC 309 32A IEC 309 32A on short cord 5 25 3U x 17 50 x 2...

Страница 33: ...ection for more detail SERVICE PLANS For service plans please see the service section beginning on page 88 POWERWARE 5125 RACKMOUNT BATTERY BACK UP TIMES in minutes Standard Load VA Watts Internal Bat...

Страница 34: ...5592 9 6 x 6 2 x 16 2 31 0 489 PW9120 BATT 1000 05147367 5592 9 6 x 6 2 x 16 2 44 0 549 PW9120 BATT 1500 05147368 5592 10 8 x 6 7 x 17 5 57 0 689 PW9120 BATT 2000 3000 05147369 5592 14 2 x 8 6 x 18 6...

Страница 35: ...dwired Hardwired 3 5 2U x 17 0 x 23 9 81 5 3 050 Notes Models do not include a rail kit Optional rail kits are available 1 Models fit in 19 inch rack enclosures 2 6 5 ft 2 meter line cord 3 L5 30R is...

Страница 36: ...om UPS as input to PowerPass except for hardwired units Note items 1 3 attach to the back of the unit they are not rackmounted POWERWARE 9125 OPTIONS Part Dimensions Weight List Description Number H x...

Страница 37: ...68 88 3000 2100 5 25 38 54 70 Note Backup times are approximate and may vary with equipment configuration battery age temperature etc POWERWARE 9125 EBC BACKUP TIMES in minutes 1 Discharge Time EXTERN...

Страница 38: ...tion Receptacles H x W x D inches 1 lb Price PPDM L6 30 103003214 6501 208 240 208 240 120 L6 30P 1 L6 30R 8 5 15R 5 25 3U x 17 4 x 24 8 106 0 999 PPDM L6 20 103003214 6502 208 240 208 240 120 L6 30P...

Страница 39: ...tail SERVICE PLANS For service plans please see the service section beginning on page 88 POWERWARE 9125 5000 6000 VA BATTERY BACKUP TIMES in minutes 1 Load VA Watts Standard Internal Batteries 1 EBM 2...

Страница 40: ...599 PDM304FFGGE L5 30P L5 20R L5 20R L5 30R L5 30R 599 PDM304GGGGE L5 30P L5 30R L5 30R L5 30R L5 30R 599 PDM304HHHHE L5 30P L5 15R 2 L5 15R 2 L5 15R 2 L5 15R 2 599 PDM304VVVVA L5 30P 1 5 50R 5 15R2 5...

Страница 41: ...ber Connection Receptacles H x W x D inches lb Price PW9140 7500 HW 103005093 6591 Hardwired Hardwired 3 C19 2 C13 10 5 6U x 17 2 x 30 0 254 0 5 394 PW9140 10000 HW 103004728 6591 Hardwired Hardwired...

Страница 42: ...0 VA Line Cord Power Module Spare 2 799 106711171 004 PW9140 10 000 VA Power Module Spare 2 799 106711172 001 PW9140 Battery Module Spare 279 POWERWARE 9140 BATTERY BACKUP TIMES in minutes 1 Load VA W...

Страница 43: ...l 32 2 x 12 x 33 7 352 0 9 965 PW9155 10 kVA 64 Battery 3 high K41012000000000 10 9 Hardwired Optional 47 8 x 12 x 33 7 590 0 11 985 PW9155 Model 10 kVA 32 Battery K41013000000000 10 9 Hardwired Optio...

Страница 44: ...Systems 124100017 001 9155 Parallel Tie Cabinet 24 0 x 20 3 x 2 2 57 3 1 499 103004336 CAN Bridge Card 519 Note Up to 3 PW9155s can be paralled within the Parallel Tie Cabinet and each UPS must includ...

Страница 45: ...92 0 136 0 12500 11250 6 1 28 8 54 0 81 6 111 0 17 6 54 0 96 2 142 0 12000 10800 6 5 30 2 56 5 85 5 116 0 18 6 56 5 101 0 149 0 11500 10350 6 9 31 6 59 3 89 7 122 0 19 2 59 3 106 0 156 0 11000 9900 7...

Страница 46: ...120 240V In Out ASY 0567 4 23 x 14 12 x 15 25 17 0 2 029 Universal Power Module 208 240V In Out ASY 0528 4 23 x 14 12 x 15 25 17 0 1 929 Battery Module two required per slot string ASY 0529 4 23 x 7...

Страница 47: ...0 x 25 5 155 0 4 583 Includes to 9 kVA N X 1 6 slot enclosure 1 power module 2 battery modules 1 caster kit PW6S6K 6 kVA expandable Hardwired Hardwired 33 3 x 17 0 x 25 5 232 0 6 997 Includes to 9 kVA...

Страница 48: ...kVA N X 3 L6 30R 1 12 slot enclosure 12 5 20R 4 power modules 8 battery modules PW12S15K PD 15 kVA expandable Hardwired 3 L14 30R 60 7 x 24 0 x 28 5 581 0 15 121 Includes to 18 kVA N X 3 L6 30R 1 12 s...

Страница 49: ...attery modules occupy 1 slot 1 String 2 String 3 String 4 String 5 String 6 String 7 String 8 String 9 String 10 String 11 String 12 String 3 kVA 6 5 16 16 40 27 5 67 5 40 98 53 5 132 67 5 167 83 204...

Страница 50: ...9 L5 30R twist lock Split Phase 1 L 59 L6 15R twist lock duplex All 1 M 79 L6 20R twist lock All 1 N 69 L6 30R twist lock All 1 O 69 Schuko Universal 1 P 69 L14 30R twist lock Split Phase 1 R 69 3 x 5...

Страница 51: ...FE000BB3A0A0A0A 120V 120V 11 31 min 5 15P 6 5 15R 1 951 FE1 4kVA FE010BB3A0A0A0A 120V 120V 22 62 min 5 15P 6 5 15R 2 210 Model FE1 8 1 8 kVA 1 25 kW FE1 8kVA FF000CC3A0A0A0B 120V 120V 11 30 min 5 20P...

Страница 52: ...min 2 430 BPE04MBB1A External maintenance bypass switch make before break 650 System List 11 800 Model FE12 5 12 5 kVA 10 kW FE12 5kVA FM140AA0A0A0A0B 208 208 120V External Hardwired Hardwired 9 312...

Страница 53: ...NS Part List Description Number Price Serial CheckUPS Cable DB25M to DB9F INT 0035 48 BestLink Web SNMP Adapter External 116750225 001 370 Signal Splitter Box IPK 0022 249 Sensaphone 1104 FGD 1104 PW...

Страница 54: ...705 40 m 1 h 42 m 27 m 1 h 14 m 2FE 3 790 1 h 11 m 2 h 51 m 49 m 2 h 10 m 34 m 1 h 28 m 3FE 4 200 1 h 49 m 4 h 05 m 1 h 12 m 3 h 08 m 48 m 2 h 13 m 4FE2 5 600 2h 06 m 4 h 46 m 1 h 27 m 3 h 39 m 60 m 2...

Страница 55: ...Charger SPK FILV 10A SPK FIHV 10A 1 449 FE4 3kVA 60 Hz Tower with 20 Amp Battery Charger SPK FILV 20A SPK FIHV 20A 1 799 FE5 3kVA 60 Hz Tower with 5 Amp Battery Charger SPK FJLV 5A SPK FJHV 5A 1 199 F...

Страница 56: ...12kW 208V w 60A 5W ZC1212010100000 12 kVA 12kW 208 208 10 5 x 17 3 x 28 0 321 0 12 150 in RPM ONLY w SNMP PWBladeUPS 208V w parallel cord ZC121P060100000 12 kVA 12kW 208 208 10 5 x 17 3 x 28 0 311 0...

Страница 57: ...RPM can be deployed in the same rack with the UPS and IT equipment there s no need for a dedicated infrastructure rack The resulting architecture has fewer cables to manage fewer distribution points...

Страница 58: ...400V 2 Select input connector option 3 Select input cord length corded units only 4 Select first receptacle plate option 5 Select second receptacle plate option 6 Select metering option 7 Select TVSS...

Страница 59: ...th 32 Battery 2 high KA1511100000010 15 kVA 13 5kW 208 208 4 32 2 x 12 0 x 33 7 373 0 15 500 PW9355 15 kVA with 64 Battery 3 high KA1512100000010 15 kVA 13 5kW 208 208 13 47 8 x 12 0 x 33 7 609 0 17 2...

Страница 60: ...2 220 B 2 5 20R UL 9 10 11 12 220 D 2 6 15R 9 10 11 12 220 E 2 6 20R 9 10 11 12 220 F 2 L5 15R 9 10 11 12 220 G 1 L5 20R 9 10 11 12 220 H 1 L5 30R 9 10 11 12 220 I 2 L6 15R 9 10 11 12 220 J 1 L6 20R 9...

Страница 61: ...36 0 21 4 65 9 117 0 174 0 10000 9000 8 4 37 2 69 8 106 0 144 0 22 6 69 8 124 0 184 0 9500 8550 9 1 39 6 74 2 112 0 153 0 24 1 74 2 132 0 196 0 9000 8100 9 9 42 3 79 4 120 0 163 0 25 7 79 4 141 0 209...

Страница 62: ...et PW9355 20 kVA Dual Feed KB2013100000010 480 208 18 66 0 x 60 0 x 34 1 2230 0 KBT002200000010 30 375 with Options Cabinets Internal Batteries 2 Opt Cabs KBT001200000010 PW9355 20 kVA Single Feed KB2...

Страница 63: ...9 Zone 4 Seismic Kit 103004896 Zone 4 Kit 1 799 Remote Monitor Panel requires Industrial Relay X Slot Card part See Page 69 for Connectivity Options Pricing CAN Bridge Parallel Card 103004336 Spare Pa...

Страница 64: ...300 12 38 62 95 114 26000 23400 13 40 65 98 118 25000 22500 14 43 68 101 124 24000 21600 14 46 71 103 129 23000 20700 15 48 74 106 134 22000 19800 16 51 76 109 144 21000 18900 17 53 79 111 152 20000 1...

Страница 65: ...tamping anti aliasing ITIC analysis and automatic trigger settings open field upgradeable firmware memory expandable to 1 GB and optional digital relay I O card Comprehensive power and power quality m...

Страница 66: ...w VAUX PX6251A5AA 7 654 PX 6000 Meter AC w VAUX Com Exp Card PX6251A5BA 8 808 PX 6000 Meter AC w VAUX I O Card PX6251A5AB 8 283 PX 6000 Meter AC w VAUX Com Exp I O Cards PX6251A5BB 9 437 PX 6000 Meter...

Страница 67: ...1 PX8251A5BB PX 8000 Meter w VAUX Std pwr 512MB CF Com Exp I O Cards Example 2 PX6251A6BA PX 6000 Meter w VAUX Std pwr 1GB CF Com Exp Card POWER XPERT 4000 6000 8000 METERS Power Quality Metering Prod...

Страница 68: ...version of PowerVision software Features and Benefits Stealth Mode Operation Cost Savings Calculator Animated UPS PowerScope View History Calendar and ControlRoom Views Separate views for single and t...

Страница 69: ...es simultaneous monitoring of multiple ConnectUPS and BD cards from a single console Powerware Extensions for IBM Director Network Management System integration software The extensions for IBM Directo...

Страница 70: ...tal package includes Server Core Layout Manager Quality Manager Modbus PXSTOTALPK 21 000 TCP Connector and SNMP Connector PowerVision v4 x Software Products Part Number List Price PowerVision Network...

Страница 71: ...Mbps power connected network connections with no additional expense Alarm notification through any combination of e mail SNMP traps or network message speeds corrective action Integrated NetWatch Clie...

Страница 72: ...with any Powerware UPS with any ConnectUPS Web SNMP card Can be located up to 20 meters 65 6 feet from the UPS Measures ambient temperatures between 20 C and 80 C Measures relatively humidity between...

Страница 73: ...options Note You can have up to two optional connectivity cards installed CONNECTIVITY Connectivity Products continued Other Connectivity Products continued Serial Cards Integration Products ConnectUP...

Страница 74: ...46 Relay Card X Slot AS 400 Compatible 1018460 146 AS 400 cables for relay cards 1014018 and 1018460 AS 400 model 9406 DB15 DB9 25 ft 103004349 5501 62 DB15 DB9 75 ft 103004347 5501 104 Industrial Rel...

Страница 75: ...pliances 185 Max Series CHSPMAX 1500 75 000 Amps 50 000 Amps Standard surge protection for major appliances and home electronics 319 Ultra Series CHSPULTRA 3500 175 000 Amps 75 000 Amps Ultimate surge...

Страница 76: ...em 132 SGXMAXTV 975 90 000 Amps 7 Outlet 5 15R 6 power Mid level protection for ac cord Transformer spacing Power Cable TV 137 SGXMAXAC 975 90 000 Amps 7 Outlet 5 15R 6 power Mid level protection for...

Страница 77: ...rcuit breaker protection protects generator circuits from overload 7000 Watt Portable Generator 12 250 Starting Watts Extended run time per tank of fuel Push button electronic start Fold down handle f...

Страница 78: ...ye Three phase 4W G PXL120208YSK 16 0 x 11 0 x 4 0 21 1 315 PXL120208YSM 25 0 x 14 0 x 8 0 40 1 715 120 240 Single Split phase 3W G PXL120240SSK 16 0 x 11 0 x 4 0 21 1 445 PXL120240SSM 25 0 x 14 0 x 8...

Страница 79: ...option Integral Disconnect 208 120 Wye Three phase 4W G PXL300208YPK 18 0 x 13 0 x 4 0 24 3 515 PXL300208YPM 25 0 x 14 0 x 8 0 40 4 315 120 240 Single Split phase 3W G PXL300240SPK 18 0 x 13 0 x 4 0 2...

Страница 80: ...25 0 x 14 0 x 8 0 40 7 705 480 Delta 3W G PXL500480DPK 18 0 x 13 0 x 4 0 24 6 805 PXL500480DPM 25 0 x 14 0 x 8 0 40 7 705 480 277 Wye Three phase 4W G PXL500480YPK 18 0 x 13 0 x 4 0 24 6 805 PXL500480...

Страница 81: ...PVL100240DK 11 55 x 5 0 x 2 6 5 1 010 480 Delta 3W G PVL100480DK 11 55 x 5 0 x 2 6 5 1 010 480 277 Wye Three phase 4W G PVL100480YK 11 55 x 5 0 x 2 6 5 1 010 PVL 120 120kA phase surge rating 208 120 W...

Страница 82: ...es RJ21 M F PDDP25B 1 25 x 3 3 x 6 63 0 78 232 25 Pairs 50 wires RJ21 M F PDDP25E 1 25 x 3 3 x 6 63 0 7 232 25 Pairs 50 wires RJ21 M F PDDP25G 1 25 x 3 3 x 6 63 0 78 232 25 Pairs 50 wires RJ21 M F PDD...

Страница 83: ...x 1 47 x 120 0 0 40 101 Low Voltage Fused RJ45 Pins 1 2 4 5 PMTJT1 0 93 x 1 47 x 3 6 0 19 51 PPCH Series Category 5 12 Ports 110 IDC RJ45 PPCH12C5 1 75 x 19 0 x 1 28 1 2 428 12 Port 110 IDC RJ45 4 Ce...

Страница 84: ...minal Block PTSP2BG 0 93 x 1 47 x 3 6 0 16 51 2 2 Center Wire Quick Connect Terminal Block PTSP2BT 0 93 x 1 47 x 3 6 0 16 51 2 2 Center Wire Quick Connect Terminal Block PTSP32BA 1 25 x 13 35 x 5 3 1...

Страница 85: ...lusive to contract customers they cannot be purchased without a corrective contract Additionally contracts are value priced compared to a single PM and an average emergency Time Materials T M event a...

Страница 86: ...for site personnel Comprehensive coverage for the entire UPS including standard batteries Toll free number for Gold Plan Plus technical support Replacement UPS or module delivered to your location by...

Страница 87: ...responsiveness with up to five years of bumper to bumper on site service system startup plus performance checks The On Site Gold Plan Plus delivers complete care of your UPS from the moment it begins...

Страница 88: ...8 for Series 5 products 7x24 for Series 9 products and Ferrups 2 Unit must be within 100 miles of Eaton established service location to qualify for 24 hr response 3 Initial start up serves as the annu...

Страница 89: ...ing 100 Domestic 250 International plus freight 3 Minimum Billing UPS and Power System UPS and Power System Equipment below 200kVA Equipment 200kVA and above or Multi Module A Five day or less respons...

Страница 90: ...ce Series 5 0STUP5100XALLC5 695 Series 9 0STUP9100XALLC5 695 Series Ferro 0STUPFERRXALLC5 695 Product Part Number List Price On Site Preventive Maintenance 5 x 8 service Series 5 0XXPM5100XALLC5 695 S...

Страница 91: ...252400XX 1 395 5 YR 5XXGX51253000CX 504 5OSGX51253000CX 1 256 5OSGP51252400XX 2 355 Base Unit 7 x 24 Service Adders Contract On Site Gold Plan On Site Gold Plan Plus Product Duration Part Number List...

Страница 92: ...overs standard internal batteries POWERWARE 9120 SERVICE PLANS On site service is 7 x 24 Contract Gold Plan On Site Gold Plan On Site Gold Plan Plus Product Duration Part Number List Price Part Number...

Страница 93: ...670 3OPGP91253000CX 2 427 5 YR 5XPGX91253000CX 1 038 5OPGX91253000CX 2 239 5OPGP91253000CX 3 198 5000 6000 2 YR 2XPGX91256000CX 515 2OPGX91256000CX 1 389 2OPGP91256000CX 1 958 3 YR 3XPGX91256000CX 1...

Страница 94: ...Part Number List Price 7 5 kVA 2 YR 2XPGX91400750CX 935 2XPGP91400750CX 1 485 2OPGX91400750CX 1 835 2OPGP91400750CX 2 711 3 YR 3XPGX91400750CX 1 636 3XPGP91400750CX 2 186 3OPGX91400750CX 2 598 3OPGP9...

Страница 95: ...ber List Price 8 10 kVA 2 YR 2OPGX915510KVCX 1 070 2OPGP915510KVCX 1 960 3 YR 3OPGX915510KVCX 1 897 3OPGP915510KVCX 3 710 5 YR 5OPGX915510KVCX 3 584 5OPGP915510KVCX 6 295 8 10 kVA 2 YR 2OPGX915510P2CX...

Страница 96: ...B9SLCX 355 2OSGP9170B9SLCX 391 9 Slot External 3 YR 3XXGP9170B9SLCX 1 528 3OSGX9170B9SLCX 1 601 3OSGP9170B9SLCX 1 697 Battery Cabinet 5 YR 5XXGP9170B9SLCX 2 920 5OSGX9170B9SLCX 3 053 5OSGP9170B9SLCX 3...

Страница 97: ...5XXGXFERRXBG2CX 946 5XXGPFERRXBG2CX 978 5OSGXFERRXBG2CX 1 140 5OSGPFERRXBG2CX 1 345 25ME 1re GROUP 3 2FE 9FE 2 YR 2XXGXFERRXBG3CX 79 2XXGPFERRXBG3CX 112 2OSGXFERRXBG3CX 177 2OSGPFERRXBG3CX 261 16FE 2r...

Страница 98: ...r 7x24 8 HR 1 YR depot Powerware Three phase UPS Models Powerware BladeUPS1 Optional Powerware 9355 UPS Optional Optional 5 Powerware PDU RPP Optional included with start up 1 Powerware BladeUPS warra...

Страница 99: ...ng eNotify remote UPS and battery monitoring SOW R 28 Extended Battery Module Replacement Depot 475 475 Coverage per EBM P N BRO9C BLADEBM BRO9C BLADEBM Adds replacement coverage for EBM 3U On Site 65...

Страница 100: ...Board 106711205 4 234 106711205 4 234 106711205 4 234 C Spares Kit 106711207 2 066 106711207 2 066 106711207 2 066 1 Start up purchase required to activate PDU warranty and Service Protection Plan co...

Страница 101: ...5015 2 175 PVN3C 9355030 2 327 2 Year Battery Labor Coverage adder1 adds labor and freight to 2YR battery parts warranty Per Cabinet Pricing BL07C 9355015 300 BL07C 9355030 300 Part numbers P N are ba...

Страница 102: ...11169 8 240 106711170 8 680 B Spares Kit 106711181 6 120 106711182 6 595 C Spares Kit 106711183 1 815 106711184 2 271 Full Battery Coverage FBC Powerware 9355 Full Battery Coverage Pricing Battery Con...

Страница 103: ...our products to verify that they meet or exceed manufacturer specifications and supply maximum runtime Using Eaton qualified batteries gives your customers confidence that their batteries will perform...

Страница 104: ...art 5 15R 5 15P 5 20R 5 20P L5 30R L5 30P 6 15R 6 15P L6 20R L6 20P 14 50R 14 50P L14 30R L14 30P IEC 320 C13 female IEC 320 C14 male L6 15R L6 15P IEC 320 C19 female IEC 320 C20 male L6 30R L6 30P IE...

Страница 105: ...pecial custom or configured products will be a minimum of 50 The buyer is responsible for both inbound and outbound freight charges Note Charges may be waived by mutual agreement between buyer and sel...

Страница 106: ...y Customer Service Engineer or Agent or f use of the Product under other than normal operating conditions or in a manner inconsistent with the Product s labels or instructions This Guaranty is not val...

Страница 107: ...packaging as the replacement Warranted Item received by the End user or as otherwise instructed by Company If Company does not receive the defective Warranted Item Company will either charge the End u...

Страница 108: ...Company hereunder whether the claims are based in contract including indemnity in tort including negligence or strict liability or otherwise shall not exceed the price of the Product on which such lia...

Страница 109: ...t and at no cost to the End user the replacement Warranted Item to the End user within one 1 business day after Company receives notice of the warranty claim In such case the End user must return at C...

Страница 110: ...under whether the claims are based in contract including indemnity in tort including negligence or strict liability or otherwise shall not exceed the price of the Product on which such liability is ba...

Страница 111: ...grees to pay for the value of the replacement Product If the Warranted Item is to be replaced by Company but the End User is unwilling or unable to supply a credit card number or purchase order for th...

Страница 112: ...which such liability is based Company shall not be responsible for failure to provide service or parts due to causes beyond Company s reasonable control END USER S OBLIGATIONS In order to receive the...

Страница 113: ...em is to be replaced by Company but the End User is unwilling or unable to supply a credit card number or purchase order for the value of the replacement Product Company will use commercially reasonab...

Страница 114: ...r otherwise shall not exceed the price of the Product on which such liability is based Company shall not be responsible for failure to provide service or parts due to causes beyond Company s reasonabl...

Страница 115: ...the Warranted Item is to be replaced by Company but the End User is unwilling or unable to supply a credit card number or purchase order for the value of the replacement Product Company will use comm...

Страница 116: ...e to causes beyond Company s reasonable control END USER S OBLIGATIONS In order to receive the benefits of this Warranty the End User must use the Product in a normal way follow the Product s user s g...

Страница 117: ...roduct b if the Product is moved to a new location by someone other than an authorized Eaton Customer Service Engineer in USA or Agent outside of USA or c if the Product s serial numbers have been rem...

Страница 118: ...months from date of Product shipment whichever occurs first for the refurbishment replacement of parts The period covered by this Warranty for Product installed and currently located outside of the fi...

Страница 119: ...xpiration of this Warranty shall not be extended upon payment of any overdue or unpaid amounts COSTS NOT RELATED TO WARRANTY The End User shall be invoiced for and shall pay for all services not expre...

Страница 120: ...PowerTrust PowerTrust Preferred LanSafe X Slot Status AGlance Powerware Hot Sync PowerVision and PowerChain Management are trade names trademarks and or service marks of Eaton Corporation or its subsi...

Отзывы: