background image

Operations and Maintenance Manual 

for Eaton Pressure Filters, Change-Over 
DWF(A) / EDWF(A) 1505, 3005, 4505, 6005

Sheet No. 

67143-4B 

Page 2/2

 

 

 

North America

 

44 Apple Street  
Tinton Falls, NJ 07724 

Toll Free: 800 656-3344 
(North America only) 

Tel: +1 732 212-4700 

 
 
Europe/Africa/Middle East

 

Auf der Heide 2 
53947 Nettersheim, Germany 

Tel: +49 2486 809-0 

Friedensstraße 41 
68804 Altlußheim, Germany 

Tel: +49 6205 2094-0 

An den Nahewiesen 24 
55450 Langenlonsheim, Germany 

Tel: +49 6704 204-0 

China

 

No. 3, Lane 280, 
Linhong Road  
Changning District, 200335  
Shanghai, P.R. China 

Tel: +86 21 5200-0099 

 
 
Singapore

 

4 Loyang Lane #04-01/02  
Singapore 508914 

Tel: +65 6825-1668 

 
 
Brazil

 

Rua Clark, 2061 - Macuco 
13279-400 - Valinhos, Brazil 

Tel: +55 11 3616-8400 

 

For more information, please 
email us at 

[email protected]  

or visit

 www.eaton.com/filtration 

© 2015 Eaton. All rights reserved. All trademarks and 
registered trademarks are the property of their respective 
owners. All information and recommendations appearing in 
this brochure concerning the use of products described 
herein are based on tests believed to be reliable. However, 
it is the user’s responsibility to determine the suitability for 
his own use of such products. Since the actual use by 
others is beyond our control, no guarantee, expressed or 
implied, is made by Eaton as to the effects of such use or 
the results to be obtained. Eaton assumes no liability arising 
out of the use by others of such products. Nor is the 
information herein to be construed as absolutely complete, 
since additional information may be necessary or desirable 
when particular or exceptional conditions or circumstances 
exist or because of applicable laws or government 
regulations. 

EN

07-2017

 

9. 

Insert the clean filter element into the filter housing. 

10.  Place the filter lid back onto the filter housing and tighten the screw plugs. The screws need to be tightened 

diametrically. Recommended tightening torques listed in the table below: 

M16 M20 M24 M27 M30 M33 

80 ± 8 Nm 

59 ± 6 ft-lb 

160 ± 15 Nm 

118 ± 11 ft-lb 

250 ± 25 Nm 

184 ± 8 ft-lb 

400 ± 40 Nm 

295 ± 30 ft-lb 

600 ± 60 Nm 

443 ± 44 ft-lb 

700 ± 70 Nm 

516 ± 52 ft-lb 

11.  Close the drain plugs 
12.  Open the pressure balance valve until operating fluid flows out of the air bleed connection without bubbles 
13.  Close the pressure balance valve and air bleeder 
14.  Retighten the screws on the lid after the vessel was pressurized for the first time. 

 

After following these instructions to change the filter element, the serviced filter vessel is ready for operation 

 

CAUTION: 

Ensure the absolute cleanliness of the filter element is maintained during the entire servicing period. 

No dirt or impurities should penetrate the filter. The new elements should remain packaged until they are installed 
to prevent contamination.  While removing an element from the a recently out of operation filter housing, make 
sure the element is fully discharged from any voltage caused by static charging during operation with certain fluids 

Do not damage element seals during servicing. All sealing have to be checked on a regular basis to avoid leakage 
and potential development of an explosive atmosphere. Any damaged seals will need to be replaced. Any 
damaged seals have  to be replaced. 

FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH, 

SEVERE INJURY, OR PROPERTY DAMAGE. 

 

5. Cleaning of the filter element 

Microglass (VG) or paper (P) filter media cannot be cleaned and need to be replaced when the dirt-holding capacity is reached. 
Wire mesh (G) filter media can be cleaned and used again. Follow the cleaning specification for Eaton filter elements, sheet no. 
21070-4 and 39448-4 to clean wire mesh filter media. 

 

6. Pressure difference measuring

 

If the filter assembly includes a clogging indicator, the indicator will measure the pressure difference across the filter element. The 
method of pressure reading varies depending on the type of indicator installed. It can be a visual, visual-electric or electronic 
reading. Additionally the G ¼" connections from the switchgear can be used for external pressure gauges. Measuring connections 
are recommended on data sheet 1650. 

 

7. Special applications

 

This filter can be used in the special applications listed below. Please follow the instructions if you are operating the filter in these 
environments. 

 

Operation in explosive areas 

 

WARNING:

 There are additional requirements for filters that are installed in explosive areas. Please follow the 

instructions on Eaton Document No. 41269. 

FAILURE TO FOLLOW THIS WARNING COULD LEAD TO 

DEATH, SEVERE INJURY, OR PROPERTY DAMAGE. 

 

Flushing operation for machines with a higher flow rate 

If flushing the filter is required before operating the equipment, follow Eaton Document No. 51354. 

 

8. Service

 

For product technical support and service, please contact the local Eaton support team. All locations and contact information are 
listed below. 

 

Spare parts respectively wearing parts have to be ordered according to the spare part list of the filter data sheet. 

 