Operations and Maintenance Manual
for Eaton Pressure Filters, Change-Over
DWF(A) / EDWF(A) 1505, 3005, 4505, 6005
Sheet No.
67143-4B
Page 2/2
North America
44 Apple Street
Tinton Falls, NJ 07724
Toll Free: 800 656-3344
(North America only)
Tel: +1 732 212-4700
Europe/Africa/Middle East
Auf der Heide 2
53947 Nettersheim, Germany
Tel: +49 2486 809-0
Friedensstraße 41
68804 Altlußheim, Germany
Tel: +49 6205 2094-0
An den Nahewiesen 24
55450 Langenlonsheim, Germany
Tel: +49 6704 204-0
China
No. 3, Lane 280,
Linhong Road
Changning District, 200335
Shanghai, P.R. China
Tel: +86 21 5200-0099
Singapore
4 Loyang Lane #04-01/02
Singapore 508914
Tel: +65 6825-1668
Brazil
Rua Clark, 2061 - Macuco
13279-400 - Valinhos, Brazil
Tel: +55 11 3616-8400
For more information, please
email us at
or visit
www.eaton.com/filtration
© 2015 Eaton. All rights reserved. All trademarks and
registered trademarks are the property of their respective
owners. All information and recommendations appearing in
this brochure concerning the use of products described
herein are based on tests believed to be reliable. However,
it is the user’s responsibility to determine the suitability for
his own use of such products. Since the actual use by
others is beyond our control, no guarantee, expressed or
implied, is made by Eaton as to the effects of such use or
the results to be obtained. Eaton assumes no liability arising
out of the use by others of such products. Nor is the
information herein to be construed as absolutely complete,
since additional information may be necessary or desirable
when particular or exceptional conditions or circumstances
exist or because of applicable laws or government
regulations.
EN
07-2017
9.
Insert the clean filter element into the filter housing.
10. Place the filter lid back onto the filter housing and tighten the screw plugs. The screws need to be tightened
diametrically. Recommended tightening torques listed in the table below:
M16 M20 M24 M27 M30 M33
80 ± 8 Nm
59 ± 6 ft-lb
160 ± 15 Nm
118 ± 11 ft-lb
250 ± 25 Nm
184 ± 8 ft-lb
400 ± 40 Nm
295 ± 30 ft-lb
600 ± 60 Nm
443 ± 44 ft-lb
700 ± 70 Nm
516 ± 52 ft-lb
11. Close the drain plugs
12. Open the pressure balance valve until operating fluid flows out of the air bleed connection without bubbles
13. Close the pressure balance valve and air bleeder
14. Retighten the screws on the lid after the vessel was pressurized for the first time.
After following these instructions to change the filter element, the serviced filter vessel is ready for operation
CAUTION:
Ensure the absolute cleanliness of the filter element is maintained during the entire servicing period.
No dirt or impurities should penetrate the filter. The new elements should remain packaged until they are installed
to prevent contamination. While removing an element from the a recently out of operation filter housing, make
sure the element is fully discharged from any voltage caused by static charging during operation with certain fluids
Do not damage element seals during servicing. All sealing have to be checked on a regular basis to avoid leakage
and potential development of an explosive atmosphere. Any damaged seals will need to be replaced. Any
damaged seals have to be replaced.
FAILURE TO FOLLOW THIS WARNING COULD LEAD TO DEATH,
SEVERE INJURY, OR PROPERTY DAMAGE.
5. Cleaning of the filter element
Microglass (VG) or paper (P) filter media cannot be cleaned and need to be replaced when the dirt-holding capacity is reached.
Wire mesh (G) filter media can be cleaned and used again. Follow the cleaning specification for Eaton filter elements, sheet no.
21070-4 and 39448-4 to clean wire mesh filter media.
6. Pressure difference measuring
If the filter assembly includes a clogging indicator, the indicator will measure the pressure difference across the filter element. The
method of pressure reading varies depending on the type of indicator installed. It can be a visual, visual-electric or electronic
reading. Additionally the G ¼" connections from the switchgear can be used for external pressure gauges. Measuring connections
are recommended on data sheet 1650.
7. Special applications
This filter can be used in the special applications listed below. Please follow the instructions if you are operating the filter in these
environments.
Operation in explosive areas
WARNING:
There are additional requirements for filters that are installed in explosive areas. Please follow the
instructions on Eaton Document No. 41269.
FAILURE TO FOLLOW THIS WARNING COULD LEAD TO
DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
Flushing operation for machines with a higher flow rate
If flushing the filter is required before operating the equipment, follow Eaton Document No. 51354.
8. Service
For product technical support and service, please contact the local Eaton support team. All locations and contact information are
listed below.
Spare parts respectively wearing parts have to be ordered according to the spare part list of the filter data sheet.