INTRODUCTION

Your 5330X-400 is an UP counting totalizer with a high-
contrast eight-digit LCD display. The front-panel reset key
can be disabled. A remote-reset terminal is provided.

APPLICATIONS

This totalizer is intended for simple totalizing applications.
One count input pulse per item is necessary. The only
decisions to be made are:

1.

Do you use the high or low speed input?

2.

Do you want the front panel reset button active?

OPERATION

The totalizer display has lead-zero blanking. No decimal
point is available.

Count Inputs

Separate contact and solid state count inputs are provided.
The solid state input (terminal 3) requires a current-sourc-
ing sensor and can count up to 10 kHz. Inputs into this
terminal are counted on the positive-going edge.

8-digit LCD
Display

FRONT VIEW

Reset
button

Plastic
front panel
sealed to
meet
NEMA 4X

REAR VIEW

Solid State input

Contact input

Reset

Ground

Durant

®

Front Panel
Reset Key
Enable

5 Enable/R

5 Enable/R

RST 4

IN A 3

IN B 2

GND 1

6 DC Common

7 +10-30VDC

                   

Count occurs on this edge of the pulse

(Voltage applied to terminal)

Terminal 3 is pulled down to common. When a sensor
output supplies voltage to this terminal, one count is regis-
tered on the display. The sourcing signal must supply at
least +1.0VDC but no more than +28VDC.

Note:  When a sourcing signal is applied to terminal 3, a
power assist feature of the Courier extends the life of the
battery.

Terminal 2 is the low-speed, current-sinking count input
designed to be used with a contact closure to ground. It has
a maximum count speed of 20 Hz. Inputs into this terminal
are counted on the negative-going edge.

          

Input realized

on this edge 

of the pulse

Contact Closes

Contact Opens

Terminal 2 is pulled up to +3VDC. When a contact closes,
pulling the voltage down to .4 VDC or less, one count is
registered.

RUN MODE

Screens

The totalizer screen is the only screen available on this
model.

Front Panel Reset Enable

The front-panel reset button comes disabled from the
factory. To enable the button, install a jumper wire from
terminal 5 to ground, terminal 1.

Note:  The reset terminal on the rear panel is still active when
the front reset button is disabled.

PROGRAM MODE

There is no program mode for this model.

2

MOUNTING

Durant

Install mounting clip

Gasket Installed?

Durant

®

2.677"(68mm)

1.299" 

(33mm)

Recommended 
Panel Cutout

5 Enable/R

5 Enable/R

RST 4

IN A 3

IN B 2

GND 1

6 DC Common

7 +10-30VDC

Содержание Durant Courier Series

Страница 1: ...put A Terminal 3 High speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz Min Low Time 80 microseconds Min High Time 20 microseconds The above times are with a 0 to 5 0 V swing Input Impedance 2ký above 5 VDC Voltage Thresholds Low 0 to 1 2 VDC High 2 0 to 28 VDC Max High 28 VDC RESET INPUT ...

Страница 2: ...wn to common When a sensor output supplies voltage to this terminal one count is regis tered on the display The sourcing signal must supply at least 1 0VDC but no more than 28VDC Note When a sourcing signal is applied to terminal 3 a power assist feature of the Courier extends the life of the battery Terminal 2 is the low speed current sinking count input designed to be used with a contact closure...

Страница 3: ...ht Display 3 WIRINGDIAGRAMS CONTACT CLOSURE COUNT INPUT FRONTPANELRESETENABLE BACKLIGHTWIRING 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC REMOTERESET 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC Current Sinking Sensor 6 to 28 VDC 1 5ký SOLID STATE INPUT CURRENT SINKING SENSOR 5 Enable R 5 Enable R RST 4 IN A 3 IN B 2 GND 1 6 DC Common 7 10 30VDC...

Страница 4: ...ERDAMAGESWHETHERDIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL OR SPECIAL OR FOR ANY EXPENSES INCURRED BY REASON OF THE USE OR MISUSE SALE OR FABRICATION OF PROD UCTS WHICH DO OR DO NOT CONFORM TO THE TERMS AND CONDI TIONS OF THIS CONTRACT INDEMNIFICATION Buyer agrees to hold Eaton harmless from defend and indemnify Eaton against damages claims and expenses arising out of subsequent sales of Durant pr...

Отзывы: