Eaton Durant Courier 5330 403 Series Скачать руководство пользователя страница 6

Durant

Installation and Operation

Manual Number 53300-903-04

Durant

Courier Models:

53300-403

Quadrature Indicator/Totalizer

53302-403

Quadrature Indicator/Totalizer w/Backlight

POWER

Internal battery: 3V, Lithium.
Life expectancy:  5 years +.
Replacement Part:  36367-202.

BACKLIGHT

10-30 VDC @ 30 mA max.
(Derate operating temperature 1°C/Volt above
17VDC.)
Reverse polarity protected.

PHYSICAL

Operation Temperature:  0° to 55°C.
Storage Temperature:  -20°C to 70°C.
Operating Humidity:  60% R.H. (Non-condensing).
Weight:  2.2 oz. net.
Display Size:  .43" high.
Front Panel Rating:  NEMA 4X when mounted with
gasket provided.
Case Material:  Cycolac X-17.

TOTALIZER

Type:  Up/Down Counting.
Digits:  8 digits positive/minus sign and 7 digits
negative.
Scaler:  0.0001 to 100.0000.
(0.0000 scales by 100 in the Courier Series).
Decimal Point:  5 positions, programmable.

DC COMMON (Terminal 1)
COUNT INPUTS A & B (Terminals 2 and 3)
Inputs A & B require a quadrature signal with a voltage
source such as a current sourcing sensor or a current
sinking sensor used with the provided pull-up resistors.

Speed:  0 to 10 kHz.
Min Low Time:  50 microseconds.
Min High Time: 20 microseconds.
(The above times are with a 0 to 5V swing.)
Input Impedance:  2K

Ω 

above 5 VDC.

Voltage  Thresholds: Low 0 to 1.2 VDC.

High 2 to 28 VDC.
Max High 28 VDC.

RESET INPUT (Terminal 4)
Resets totalizer when connected to DC common.

Min Low Time:  0.25 to 1.0 sec. (maintained).
The required pulse width varies with count speed,
scale factor and number of digits displayed.
Voltage  Thresholds: Low 0 to 0.4 VDC.

High 2.0 to 28 VDC.

PROGRAM ENABLE INPUT (Terminal 5)

Operation:  Level sensitive (maintained).

COUNT ACCURACY

100% when operated within specifications.

Recommended 

Panel Cutout

2.95" (74.93mm)

1.57" 

(39.87mm)

1.25" 

(31.75mm)

2.677" (68mm)

1.299" 

(33mm)

RESET

Durant®

Содержание Durant Courier 5330 403 Series

Страница 1: ... Key Enable Disable OPERATION Quadrature Counting Quadrature is a bi directional count mode requiring an in put signal at each of the totalizer s two count inputs Quadra ture counting is typically accomplished by using a quadra ture encoder as the count source although any two sen sors with single channel outputs may be used if the sen sors are positioned correctly In either case both sensor outpu...

Страница 2: ...far right digit will be flashing Press the RST key until reaching the desired digit value Note Pressing and holding the RST key will cause the numbers to autoscroll Next press the key to move the flashing digit one place to the left Change this digit to the desired value with the RST key Repeat this process until all digits are set correctly Setting the count scale factor to 0 0000 will allow scal...

Страница 3: ...erature specifications Do not mount this unit in a heavy vibration area BATTERYSAFETY The lithium battery that powers your device contains in flammable materials such as lithium organic solvent and other chemical ingredients Explosion or fire may result if the battery is not handled correctly To avoid an accident follow these guidelines Do not heat batteries above 95 C Do not recharge lithium batt...

Страница 4: ...HALL EATON BE LIABLE FOR CLAIMS BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR NEGLIGENCE OR ANY OTHER DAMAGES WHETHERDIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL ORSPECIALORFORANYEXPENSESINCURREDBYREASONOF THE USE OR MISUSE SALE OR FABRICATION OF PRODUCTS WHICH DO OR DO NOT CONFORM TO THE TERMS AND CONDI TIONS OF THIS CONTRACT INDEMNIFICATION Buyer agrees to hold Eaton harmless from defend and...

Страница 5: ...Durant Products 901 S 12th Street Watertown WI 53094 800 540 9242 920 261 4070 Fax 920 261 9097 www durant com ...

Страница 6: ... Series Decimal Point 5 positions programmable DC COMMON Terminal 1 COUNT INPUTS A B Terminals 2 and 3 Inputs A B require a quadrature signal with a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz Min Low Time 50 microseconds Min High Time 20 microseconds The above times are with a 0 to 5V swing Input Impedance...

Отзывы: