3

Enabling the Front Panel Reset Key

The fourth screen in the program mode allows the user to
enable or disable the front panel reset key.

Du rant

®

RS T

Press the 

RST

 key to choose the option you want.

Note:  The reset terminal on the rear panel is still active
when the front reset button is disabled.

To exit the program mode, break the connection between
terminals 1 and 5.

WIRING RECOMMENDATIONS

Following these suggestions will increase noise immunity
and lengthen unit life.

Cable:  The connection between the count source and the
ratemeter should be made with a two-conductor shielded
cable. The shield should be connected to earth ground at
one end only. The connecting cable should not be run in
conduits with cables switching high inductive loads.

Relay Coil Suppression:  If a relay contact is used as a
count source, the relay coil should be suppressed. This
can be accomplished with an RC network for AC coils or a
diode for DC coils. The Durant RC suppressor (38091-
400) may be used.

Mounting:  The totalizer should not be mounted near a
solenoid or other inductive devices. Enough ventilation
should be supplied to keep the ratemeter operating within
the temperature specifications. Do not mount this unit in a
heavy vibration area.

BATTERY SAFETY

The lithium battery that powers your device contains in-
flammable materials such as lithium organic solvent, and
other chemical ingredients. Explosion or fire may result if
the battery is not handled correctly. To avoid an accident
follow these guidelines:

*

Do not heat batteries above 95°C

*

Do not recharge lithium batteries

*

Do not dispose of batteries in fire

*

Insert battery with correct polarity

WIRING DIAGRAMS

Solid State Quadrature Input

Current Sourcing Sensor

5   E n a b le /R

5   E n a b le /R

R S T  4

IN  A  3

IN  B  2

G N D   1

+

-

6   D C   C o m m o n

7   + 1 0 -3 0 V D C

5   E n a b le / R

5   E n a b le / R

R S T  4

IN  A  3

IN  B  2

G N D   1

6   D C   C o m m o n

7   + 1 0 -3 0 V D C

C urrent Sink ing 
S ens or

+ 6  +2 8    V D C  
1 .5 k  

Program Mode Enable & Backight Wiring

5   E n a b le /R

5   E n a b le /R

R S T   4

IN  A  3

IN  B  2

G N D   1

6   D C   C o m m o n

7   + 1 0 -3 0 VD C

+

Remote Reset

5   E n a b le /R

5   E n a b le /R

R S T   4

IN  A  3

IN  B  2

G N D   1

6  D C   C o m m on

7   + 1 0 -3 0 VD C

Term in al

 

 

 

 

 

 

F u nc tio n

 

G ro und 

Inp ut B  

C oun t Inpu t 

Inp ut A  

C oun t Inpu t 

R es et 

 

P rog ra m  

E n able 

B a ck light 

C om m on 

B a ck light 

P o w er 

O p eratio n

 

 

U s e w ith C urrent S ourcing 

Q uadratu re  C ount  S ourc e 

U s e w ith C urrent S ourcing 

Q uadratu re  C ount  S ourc e  

C onn ec t through  C onta ct C los e 

to G round  

C onn ec t to G round  to E n ter  

P rog ra m   M od e 

 

 

C onn ec t to P ow er to 

Light D isp lay

Solid State Quadrature Input

Current Sinking Sensor

Содержание Durant Courier 5330 403 Series

Страница 1: ... Key Enable Disable OPERATION Quadrature Counting Quadrature is a bi directional count mode requiring an in put signal at each of the totalizer s two count inputs Quadra ture counting is typically accomplished by using a quadra ture encoder as the count source although any two sen sors with single channel outputs may be used if the sen sors are positioned correctly In either case both sensor outpu...

Страница 2: ...far right digit will be flashing Press the RST key until reaching the desired digit value Note Pressing and holding the RST key will cause the numbers to autoscroll Next press the key to move the flashing digit one place to the left Change this digit to the desired value with the RST key Repeat this process until all digits are set correctly Setting the count scale factor to 0 0000 will allow scal...

Страница 3: ...erature specifications Do not mount this unit in a heavy vibration area BATTERYSAFETY The lithium battery that powers your device contains in flammable materials such as lithium organic solvent and other chemical ingredients Explosion or fire may result if the battery is not handled correctly To avoid an accident follow these guidelines Do not heat batteries above 95 C Do not recharge lithium batt...

Страница 4: ...HALL EATON BE LIABLE FOR CLAIMS BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR NEGLIGENCE OR ANY OTHER DAMAGES WHETHERDIRECT IMMEDIATE FORESEEABLE CONSEQUENTIAL ORSPECIALORFORANYEXPENSESINCURREDBYREASONOF THE USE OR MISUSE SALE OR FABRICATION OF PRODUCTS WHICH DO OR DO NOT CONFORM TO THE TERMS AND CONDI TIONS OF THIS CONTRACT INDEMNIFICATION Buyer agrees to hold Eaton harmless from defend and...

Страница 5: ...Durant Products 901 S 12th Street Watertown WI 53094 800 540 9242 920 261 4070 Fax 920 261 9097 www durant com ...

Страница 6: ... Series Decimal Point 5 positions programmable DC COMMON Terminal 1 COUNT INPUTS A B Terminals 2 and 3 Inputs A B require a quadrature signal with a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed 0 to 10 kHz Min Low Time 50 microseconds Min High Time 20 microseconds The above times are with a 0 to 5V swing Input Impedance...

Отзывы: