Effective July 2010
Instructional Leaflet
IL8700C39-04
OPTIM
OPTIM
DIGITRIP RMS Type
510
610
810
910
750
1050
Instruction Leaflet No.
I.L. 29-885 I.L. 29-886 I.L. 29-888 I.L. 29-889 I.L. 29C891 I.L. 29C891
Long Delay Setting
X
X
X
X
X
X
Long Delay Time
X
X
X
X
X
X
Long Time Slope (I2t - I4t)
X
X
Long Time Memory Powered
X
X
X
X
X
X
Overtemperature
X
X
X
X
X
X
Short Delay Pick-up
OPT.
OPT.
OPT.
OPT.
X
X
Short Delay Time
OPT.
OPT.
OPT.
OPT.
X
X
Flat/I2T Response
X
X
X
X
X
X
Zone Interlocking
j
j
j
j
j
j
Instantaneous Pick-up
OPT.
OPT.
OPT.
OPT.
X
X
DIScriminator Disable
s
s
s
s
X
X
Ground Fault Pick-up
OPT.
OPT.
OPT.
OPT.
OPT.
OPT.
Ground Fault Time
OPT.
OPT.
OPT.
OPT.
OPT.
OPT.
Flat/I2t Response
X
X
X
X
X
X
Ground Time Memory
X
X
X
X
X
X
Zone Interlocking
j
j
j
j
j
j
Ground Fault Alarm Only
OPT.
OPT.
Interchangeable Rating Plug
X
X
X
X
X
X
Auto Lockout After Trip
X
X
X
X
X
Mode of Trip LEDs
X
X
X
X
X
X
Battery - for Mode of Trip LEDs
X
X
X
X
X
X
Battery Status LED (Green)
X
X
X
X
X
X
Battery Test Pushbutton
X
X
X
X
X
X
Power/Relay Module
X
X
X
X
X
Remote Signal Contact
High Load Alarm
X
X
X
X
X
Long Delay Trip
X
X
X
X
X
Short Circuit Trip
X
X
X
X
X
Ground Fault Trip
o
o
o
o
o
Ground Alarm
Integral Test Provisions
X
X
X
X
Trip Unit Status Indication LED
X
X
X
X
X
X
Display Message Test
l
l
4 Digit Display
X
X
X
IA Current
X
X
X
IB Current
X
X
X
IC Current
X
X
X
IG Ground
o
o
o
Display Stepping Pushbutton
X
X
X
Total Harmonic Distortion [THD] LED
X
Per Harmonic
X
Waveform Capture
m
m
4 Digit Display
Phase to Phase [VAB] LED
X
Phase to Phase [VBC] LED
X
Phase to Phase [VCA] LED
X
Pr
ot
ection
V
oltag
e
Met
er
ing
Har
monic
Cur
rent
Cur
rent Met
er
ing
(Local and Remot
e)
Test
Remot
e Signals
Local
Tr
ip
Indicat
ors
X = Standard
j
Use of zone interlocking is optional with breaker wiring modification.
OPT = Optional
k
Remote location only unless optional AEM local monitor is used.
l
Local on face of trip unit. Remote via INCOM/IMPACC to AEM1 or AEM2 or direct to host computer.
m
Remote only - direct to host computer via INCOM/IMPACC.
n
On AEM denoted by absence of response from addressed breaker.
o
Supplied only when trip unit is equipped with ground fault protection option.
p
Requires spring release or electrical operator option.
7
eaTOn CORPORaTIOn
www.eaton.com
Table 1 Digitrip Trip Unit Characteristics