background image

Instruction Leaflet 

IL17559 Rev. D

 

Instructions for the DeviceNet

®

 Product

 

Effective August 2009

 

Operated Network Interface (DPONI)

 

EATON CORPORATION

 

www.eaton.com

 

20

Table D-7.  Format of Assembly Instance #155 (9Bh) – Motor Trip Counts. 

Word # 

Member 

Parameter 

Inst # 

Data Bytes 

Status 32 

StatusByte 

33 

GndFaultTripsCnt 91  2 

I2TtripsCnt 

92 

InstOCurTripsCnt 93  2 

JamTripsCnt 

94 

UndrLdTripsCnt 95 2 

PhsUnbalTripsCnt 

96 

WindTempTripsCnt 97  2 

MotrBrngTripsCnt 

98 

10 

LoadBrngTripsCnt 99  2 

11 

AuxTempTripsCnt 

100 

12 

PhsRvrsTripsCnt 101  2 

13 

IncmSeqTripsCnt 

102 

14 

RemoteTripsCnt 103  2 

15 

DiffrntlTripsCnt 

104 

16 

StrtPerTTripsCnt 105  2 

17 

TBtnStrtTripsCnt 

106 

18 

XsitionTripsCnt 107 2 

19 

TripBypsTripsCnt 

108 

20 

ZeroSpdSTripsCnt 109  2 

21 

VltUnbalTripsCnt 

110 

22 

UndrFreqTripsCnt 111  2 

23 

OverFreqTripsCnt 

112 

24 

OverVoltTripsCnt 113  2 

25 

UndrVoltTripsCnt 

114 

26 

UndrPwrTripsCnt 115  2 

27 

PwrFactrTripsCnt 

116 

28 

TcLastResetDateM 117  2 

29 

TcLastResetDateD 

118 

30 

TcLastResetDateY 119  2 

31 

TcLastResetTimeH 

120 

32 

TcLastResetTimeM 121  2 

33 

TcLastResetTimeS 

122 

 

Содержание DeviceNet Product Operated Network Interface

Страница 1: ...implified Wiring Rules 4 Operational Check 4 LED Definitions and Diagnostics 4 Combined Module Network Status NS LED 4 5 WIRE TX 5 Troubleshooting 5 Specifications 5 DeviceNet Cable Specifications 5 Maintenance and Care 5 Appendix A Parameter Object Instances for MP 3000 6 Appendix B Assembly Object Instances for MP 3000 9 Appendix C Parameter Object Instances for MP 4000 14 Appendix D Assembly Ob...

Страница 2: ...rience and judgment and may not cover all contingencies If further information is required an Eaton sales office should be consulted Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser THERE ARE NO UNDERSTANDINGS AGREEMENTS WARRANTIES EXPRESSED OR IMPLIED IN...

Страница 3: ... DPONI supports explicit mode and polled I O connections Volume 3 of the CIP Networks Library provides details of these communications modes The DPONI must be reset following an address change via the address switches by removing power from the DPONI host connection This can be accomplished by cycling power to the host device The DPONI allows monitoring and control only Changing setpoints is not s...

Страница 4: ...s 500 m 1640 ft for thick trunk cable The maximum total cable distance at 250 Kbps is 250 m 820 ft for thick trunk cable The maximum total cable distance at 500 Kbps is 100 m 328 ft for thick trunk cable The maximum length of mixed cables may be found by solving the following equation LThick 5 LThin 500 m 1640 ft LThin must not exceed 156 m 511 ft The most common power configuration is shown in Fi...

Страница 5: ... 6 If suggestions 1 through 5 do not remedy the problem the DPONI may need to be replaced CAUTION DO NOT ATTEMPT TO SERVICE THIS EQUIPMENT OTHERWISE SERIOUS INJURY OR DEATH AND OR EQUIPMENT DAMAGE MAY RESULT Specifications Table 2 DeviceNet Connector Ratings Connector Rating V 11 Vdc to 27 Vdc inrush 300 mA steady state 40 mA maximum 3 VA V DeviceNet common CANH Reverse wiring protected to 27 Vdc ...

Страница 6: ...UINT 2 Get 0 15 1 0 300 37 FlagsStatus UINT 2 Get 0 6 1 0 3C8 38 FlagsReason UINT 2 Get 0 40 1 0 3C8 39 SlaveActions WORD 2 Set Get 0 65535 1 0 3D0 40 WindingTemp1 DegC INT 2 Get 1 255 1 0 30F N 1 41 WindingTemp2 DegC INT 2 Get 1 255 1 0 30F N 1 42 WindingTemp3 DegC INT 2 Get 1 255 1 0 30F N 1 43 WindingTemp4 DegC INT 2 Get 1 255 1 0 30F N 1 44 WindingTemp5 DegC INT 2 Get 1 255 1 0 30F N 1 45 Wind...

Страница 7: ...INT 2 Get 0 65535 1 0 30F N 25 86 TotalRunTime Hour UINT 2 Get 0 65535 1 0 30F N 25 87 TotalTripsCnt UINT 2 Get 0 65535 1 0 30F N 25 88 GndFaultTripsCnt UINT 2 Get 0 255 1 0 30F N 26 89 I2TtripsCnt UINT 2 Get 0 255 1 0 30F N 26 90 InstOCurTripsCnt UINT 2 Get 0 255 1 0 30F N 26 91 JamTripsCnt UINT 2 Get 0 255 1 0 30F N 26 92 UndrLdTripsCnt UINT 2 Get 0 255 1 0 30F N 26 93 PhsUnbalTripsCnt UINT 2 Ge...

Страница 8: ...teM Mnth UINT 2 Get 1 12 1 0 30F N 27 126 AcLastResetDateD Day UINT 2 Get 1 31 1 0 30F N 27 127 AcLastResetDateY Year UINT 2 Get 2001 2099 1 0 30F N 27 128 AcLastResetTimeH Hour UINT 2 Get 0 23 1 0 30F N 27 129 AcLastResetTimeM Min UINT 2 Get 0 59 1 0 30F N 27 130 AcLastResetTimeS Sec UINT 2 Get 0 59 1 0 30F N 27 131 FlagsBitsB15B00 WORD 2 Get 0 65535 1 0 3C8 132 FlagsBitsB31B16 WORD 2 Get 0 65535...

Страница 9: ...ts assembly instance 151 temperatures Use the hex value of the desired instance to select the appropriate assembly Next send the explicit message to the DPONI to change the polled assembly instance Produced Assembly Instances There are eight producing assemblies supported for the MP 3000 as indicated in the following table Table B 1 Produced Assembly Instances Inst Assembly Name Number of Data Byt...

Страница 10: ...mp4 43 2 6 WindingTemp5 44 2 7 WindingTemp6 45 2 8 MotorBrngTemp1 46 2 9 MotorBrngTemp2 47 2 10 LoadBrngTemp1 48 2 11 LoadBrngTemp2 49 2 12 AuxiliaryTemp 50 2 Table B 4 Format of Assembly Instance 152 98h Currents Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 CurrentPhA 51 2 3 CurrentPhB 52 2 4 CurrentPhC 53 2 5 CurrentGnd 54 2 6 CurrentAvg3Ph 55 2 Table B 5 Format of Ass...

Страница 11: ...astResetDateY 81 2 20 MoLastResetTimeH 82 2 21 MoLastResetTimeM 83 2 22 MoLastResetTimeS 84 2 23 TotalStartsCnt 85 2 24 TotalRunTime 86 2 25 TotalTripsCnt 87 2 Table B 7 Format of Assembly Instance 155 Motor Trip Counts Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 GndFaultTripsCnt 88 2 3 I2TtripsCnt 89 2 4 InstOCurTripsCnt 90 2 5 JamTripsCnt 91 2 6 UndrLdTripsCnt 92 2 7 ...

Страница 12: ...ResetDateM 125 2 15 AcLastResetDateD 126 2 16 AcLastResetDateY 127 2 17 AcLastResetTimeH 128 2 18 AcLastResetTimeM 129 2 19 AcLastResetTimeS 130 2 Table B 9 Format of Assembly Instance 157 Flags Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 FlagsStatus 37 2 3 FlagsReason 38 2 4 FlagsBitsB15B00 131 2 5 FlagsBitsB31B16 132 2 6 FlagsBitsB47B32 133 2 7 FlagsBitsB63B48 134 2 C...

Страница 13: ...9 EATON CORPORATION www eaton com 13 Table B 12 Data Bit Definitions Slave Actions Bit Slave Action Requested 0 ResetTripAlm 1 ResetMotrMax 2 ResetMotrTrp 3 ResetMotrAlm 4 StopTrip 5 EmrgOvrdTrip 6 RelsMajrEvnt 7 ResetHistory 8 RelsMinrEvnt 9 RelsStrtProf 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Reserved 15 Reserved ...

Страница 14: ...INT 2 Get 0 15 1 0 300 37 FlagsStatus UINT 2 Get 0 42 1 0 3C8 38 FlagsReason UINT 2 Get 0 329 1 0 3C8 39 SlaveActions WORD 2 Set Get 0 65535 1 0 3D0 40 WindingTemp1 DegC INT 2 Get 1 255 1 0 30F N 1 41 WindingTemp2 DegC INT 2 Get 1 255 1 0 30F N 1 42 WindingTemp3 DegC INT 2 Get 1 255 1 0 30F N 1 43 WindingTemp4 DegC INT 2 Get 1 255 1 0 30F N 1 44 WindingTemp5 DegC INT 2 Get 1 255 1 0 30F N 1 45 Win...

Страница 15: ...INT 2 Get 0 23 1 0 30F N 25 86 MoLastResetTimeM Min UINT 2 Get 0 59 1 0 30F N 25 87 MoLastResetTimeS Sec UINT 2 Get 0 59 1 0 30F N 25 88 TotalStartsCnt UINT 2 Get 0 65535 1 0 30F N 25 89 TotalRunTime Hour UINT 2 Get 0 65535 1 0 30F N 25 90 TotalTripsCnt UINT 2 Get 0 65535 1 0 30F N 25 91 GndFaultTripsCnt UINT 2 Get 0 255 1 0 30F N 26 92 I2TtripsCnt UINT 2 Get 0 255 1 0 30F N 26 93 InstOCurTripsCnt...

Страница 16: ...Hour UINT 2 Get 0 23 1 0 30F N 27 145 AcLastResetTimeM Min UINT 2 Get 0 59 1 0 30F N 27 146 AcLastResetTimeS Sec UINT 2 Get 0 59 1 0 30F N 27 147 FlagsBitsB15B00 WORD 2 Get 0 65535 1 0 3C8 148 FlagsBitsB31B16 WORD 2 Get 0 65535 1 0 3C8 149 FlagsBitsB47B32 WORD 2 Get 0 65535 1 0 3C8 150 FlagsBitsB63B48 WORD 2 Get 0 65535 1 0 3C8 151 FlagsBitsB79B64 WORD 2 Get 0 65535 1 0 3C8 152 DiscreteInputs WORD...

Страница 17: ...88 Reserved 189 Reserved 190 NetEnergyVarHr VH 1 DINT 4 Get 2 31 2 31 1 1 0 30F N 8 191 EnergyVAHr Vah 1 UDINT 4 Get 0 2 32 1 1 0 30F N 8 192 EnergyUnitsId 1 UINT 2 Get 3 6 1 0 30F N 8 193 EnLastResetDateM Mnth UINT 2 Get 1 12 1 0 30F N 8 194 EnLastResetDateD Day UINT 2 Get 1 31 1 0 30F N 8 195 EnLastResetDateY Year UINT 2 Get 2001 2099 1 0 30F N 8 196 EnLastResetTimeH Hour UINT 2 Get 0 23 1 0 30F...

Страница 18: ...s 22 Get 159 Power 62 Get 160 Energy 30 Get 161 Reserved Get 162 Reserved Get 163 Reserved Get 164 Reserved Get Table D 2 Format of Assembly Instance 150 96h Status Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 Table D 3 Format of Assembly Instance 151 97h Temperatures Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 WindingTemp1 40 2 3 WindingTemp2 4...

Страница 19: ...9Ah Motor Maximums Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 MaxStartCurrent 64 2 3 MaxRunCurrent 65 2 4 MaxPhaseUnbal 66 2 5 MaxWindingTemp 67 2 6 MaxMotBrngTemp 68 2 7 MaxLoadBrngTemp 69 2 8 MinLGVoltage 70 2 9 MaxLGVoltage 71 2 10 MaxVltPhaseUnbal 72 2 11 MxLastResetDateM 73 2 12 MxLastResetDateD 74 2 13 MxLastResetDateY 75 2 14 MxLastResetTimeH 76 2 15 MxLastReset...

Страница 20: ...nt 97 2 9 MotrBrngTripsCnt 98 2 10 LoadBrngTripsCnt 99 2 11 AuxTempTripsCnt 100 2 12 PhsRvrsTripsCnt 101 2 13 IncmSeqTripsCnt 102 2 14 RemoteTripsCnt 103 2 15 DiffrntlTripsCnt 104 2 16 StrtPerTTripsCnt 105 2 17 TBtnStrtTripsCnt 106 2 18 XsitionTripsCnt 107 2 19 TripBypsTripsCnt 108 2 20 ZeroSpdSTripsCnt 109 2 21 VltUnbalTripsCnt 110 2 22 UndrFreqTripsCnt 111 2 23 OverFreqTripsCnt 112 2 24 OverVolt...

Страница 21: ...OverFreqAlrmsCnt 137 2 17 OverVoltAlrmsCnt 138 2 18 UndrVoltAlrmsCnt 139 2 19 UndrPwrAlrmsCnt 140 2 20 AcLastResetDateM 141 2 21 AcLastResetDateD 142 2 22 AcLastResetDateY 143 2 23 AcLastResetTimeH 144 2 24 AcLastResetTimeM 145 2 25 AcLastResetTimeS 146 2 Table D 9 Format of Assembly Instance 157 9Dh Flags Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 FlagsStatus 37 2 3 F...

Страница 22: ...wrPhB 171 4 9 RealPwrPhC 172 4 10 ReactPwrPhA 173 4 11 ReactPwrPhB 174 4 12 ReactPwrPhC 175 4 13 ApparPwrPhA 176 4 14 ApparPwrPhB 177 4 15 ApparPwrPhC 178 4 16 PwrFactorApprPhA 182 2 17 PwrFactorApprPhB 183 2 18 PwrFactorApprPhC 184 2 19 20 21 22 23 24 Table D 12 Format of Assembly Instance 160 Energy Word Member Parameter Inst Data Bytes 0 Status 32 2 1 StatusByte 33 2 2 NetEnergyWattHr 187 4 3 N...

Страница 23: ...bly Name Number of Data Bytes Access 100 SlaveActions 2 Set 101 Reserved Set 102 Reserved Set 103 Reserved Set Table D 14 Format of Assembly Instance 100 Slave Actions Word Member Parameter Inst Data Bytes 0 SlaveActions 39 2 Table D 15 Data Bit Definitions Slave Actions Bit Slave Action Requested 0 ResetTripAlm 1 ResetMotrMax 2 ResetMotrTrp 3 ResetMotrAlm 4 StopTrip 5 EmrgOvrdTrip 6 RelsMajrEvnt ...

Страница 24: ...eaton com Internet www eaton com Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township PA 15108 United States 877 ETN CARE 877 386 2273 eaton com 2009 Eaton Corporation All Rights Reserved Printed in USA Publication No IL17559 Rev D TBG 000257 August 2009 PowerChain Management is a registered trademark of Eaton Corporation All Other trademarks are property of their respective o...