background image

Semi-Auto Control Installation, Operation & Maintenance 

 

DOM0000018-EN, Revision A 

 

Page 3 of 4 

Control Logic 

Your control logic should be configured to allow the purge sequence to 

occur by the following methods. Reference Sequence Diagram and 

Control Philosophy supplied by EATON with the unit. The end user is 

responsible for system function.  
 

 

Troubleshooting 

Symptoms 

A

 

Actuator doesn’t operate properly 

B

 

Purge valve will not operate properly 

C

 

Leakage at lid seal 

D

 

Leakage where drive shaft enters lid 

E

 

Reduction in flow rate or high differential pressure 

F

 

Drop in filtrate quality 

Possible Faults 

A

 

Actuator doesn’t operate properly 

1

 

No power 

a

 

Check to see if the filter system is receiving adequate 

power. 

b

 

Check to see if the filter system is set to the proper 

voltage. 

c

 

Check all wiring connections. 

2

 

No air 

a

 

Check to see if the filter system is receiving adequate 

air. 

b

 

Check for air leaks. 

c

 

Check to see if the air bleed valve is closed and the air 

block valve is open. 

d

 

Check to see if the air lines are connected to the 

correct ports. 

3

 

Actuator seals have been destroyed 

a

 

Order a factory repair kit and replace the seals. 

4

 

Faulty solenoid valve 

a

 

Check to see whether the manual override button on 

the solenoid valve actuates the cylinder 

5

 

Cleaning disc not cleaning the filter screen 

a

 

Inspect and clean the filter screen. 

b

 

Inspect and replace the cleaning disc. 

B

 

Purge valve will not operate properly 

1

 

No power 

a

 

Check to see if the filter system is receiving adequate 

power. 

b

 

Check to see if the filter system is set to the proper 

voltage. 

c

 

Check all wiring connections. 

2

 

No air 

a

 

Check to see if the filter system is receiving adequate 

air. 

b

 

Check for air leaks. 

c

 

Check to see if the air bleed valve is closed and the air 

block valve is open. 

d

 

Check to see if the air lines are connected to the 

correct ports. 

3

 

Actuator seals have been destroyed 

a

 

Order a factory repair kit and replace the seals. 

4

 

Faulty solenoid valve 

a

 

Check to see whether the manual override button on 

the solenoid valve actuates the cylinder 

5

 

Damaged purge valve 

a

 

Replace or rebuild purge valve 

6

 

Debris caught in purge valve 

a

 

Remove debris from purge valve 

C

 

Leakage at lid seal 

1

 

Loose lid nuts/bolts 

a

 

Tighten lid/nut bolts to 

2

 

Dirty lid sealing surfaces 

a

 

Clean lid sealing surfaces 

3

 

Damaged sealing surfaces 

a

 

Repair or replace filter station 

4

 

Worn lid O-ring 

a

 

Remove and replace with factory lid O-ring 

D

 

Leakage where drive shaft enters lid 

1

 

Damaged or worn drive shaft seal 

a

 

Inspect and replace the drive shaft seal 

E

 

Reduction in flow rate or high differential pressure 

1

 

Purge time too long 

a

 

Decrease purge timer setting 

2

 

Purge valve not functioning 

a

 

Inspect and replace purge valve 

3

 

Dirty or damaged filter screen 

a

 

Inspect and clean or replace filter screen 

4

 

Flow, viscosity or solids increase 

a

 

Consult factory 

5

 

Cleaning disc not cleaning 

a

 

Inspect cleaning disc for wear and replace if necessary 

F

 

Drop in filtrate quality 

1

 

High differential pressure 

a

 

Refer to reduction in flow rate or high differential 

pressure above 

2

 

Damaged filter screen O-rings 

a

 

Remove and replace with factory filter screen O-rings 

3

 

Damaged filter screen 

a

 

Remove and replace with factory filter screen 

4

 

Filter screen too coarse 

a

 

Consult factory for ability of filter system to accept a 

finer screen retention. Remove and replace with 

factory filter screen. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Отзывы: