3.Type and Name
Category of application:
1. HRL=Hazardous recessed LED Lighting
2. Indicates Outline
/3060 =(only for 30W)
/3012= (only for 60W)
/6060=(only for 60W)
3.Indicates Housing material
/00=Galvanized steel with powder coated
/16=SS316L with powder coated
4.Indicates lighting power
/30w=30w
/60w=60w
5.IndicatesLED color temperature
/30=3000K
/40=4000K
/50=5000K
/57=5700K
6.Indicates Emergency durations
/Default=Non-Emergency
/EM2=1.5H 25% output
/EM3=3H,25% output
7.Indicates entry types and size
/1-225=Single ended 2xM25
/2-225=Through wiring 4xM25
/1-220=Single ended 2xM20
/2-220=Through wiring 4XM20
8.Indicates Terminal Type and Size
Default=Double Row Terminal
/T1=Single Row Terminal
9.Indicated Safety Switch
Default=W/O safety switch
/S=W/ safety switch
IM1465 Rev.2 2020/09 Cooper Electric (Changzhou) Co., Ltd. Page1/7
1.Safety Instructions
This product should be installed, inspected, and maintained by a qualified
electrician only, in accordance with national regulation, including the
relevant standard and, where applicable, in acc. With IEC 60079-17 on
electrical apparatus for explosive atmospheres.
The national safety rules and regulations for prevention of accidents and
the following safety instructions in these operating instructions, will have
to be observed!
The luminaire must not be operated in Zone0 and in Zone20!
When using in Zone21,Zone22, the requirements of IEC/EN 60079-14
relating to temperature must be observed. The indicated surface
temperatures are not related to a layers above 5 mm thickness.
Do not install where the marked operating temperature exceed the ignition
temperature of the hazardous atmosphere.
Do not operate in ambient temperatures above those indicated on the
luminaire nameplate.
The luminaires shall be operated as intended and only in undamaged and
perfect conditions! And Keep tightly closed when in operation!
The technical data indicated on the luminaire are to be observed!
Change of the design and modifications to the luminaire are not permitted!
Multiple, short-term switching must be observed!
Only genuine Eaton Crouse-Hinds spare parts may be used for replacement!
Repairs that affect the explosion protection, may only be carried out by
Eaton Crouse-Hinds or qualified electrician!
Potential electrostatic risk clean only with a damp cloth
!
2.
Conformity with standards
This explosion protection floodlight meet the requirements of IEC/EN 60079-
0, IEC/EN 60079-1, IEC/EN 60079-7, IEC 60079-11, IEC 60079-18, IEC/EN
60079-31. It also complies with the EC Directives for “Apparatus and
protective system for use in explosion atmospheres” (2014/34/EU). It has
been designed, manufactured and tested in accordance to the state of the art
and according to ISO 9001:2008. The luminaires are suitable for use in
explosive atmospheres, Zone1,Zone2 according to IEC60079-10-1 and dust
area Zone21 and Zone22 according to IEC60079-10-2.
4. Technical data
Hazardous area specification
Type of
protection:
Ex db, eb, ib, mb, tb
Dust protected enclosure
IEC Certification
Marking:
Ex db eb ib mb op is IIC T6 Gb(EM with Switch)
Ex db eb mb op is IIC T6 Gb (Normal with Switch)
Ex eb ib mb op is IIC T6 Gb (EM w/o Switch)
Ex eb mb op is IIC T6 Gb (Normal w/o Switch)
Ex op is tb IIIC T80
℃
Db(All types)
ATEX
Certification
Marking:
II2 G Ex db eb mb op is IIC T6 Gb (Normal with Switch)
II2 G Ex db eb ib mb op is IIC T6 Gb (EM with Switch)
II2 G Ex eb mb op is IIC T6 Gb(Normal w/o Switch)
II2 G Ex eb ib mb op is IIC T6 Gb(EM w/o Switch)
II2 D Ex op is tb IIIC T80
℃
Db(For all types)
Ambient
temperature:
-40ºC~+55 ºC--- Normal Version
-25ºC~+55 ºC--- EM version
Temperature
class: T6
ATEX/IECEx
Certificate No.:
SEV 19 ATEX 0101X/
IECEx SEV 19.0001X
Degree of
protection:
IP 66 acc. to EN60529/IEC60529
Enclosure specification
Material of
enclosure:
Galvanized steel
SS316L
Finish: Powder Coating
Material of cover: PC
Mounting bracket: Stainless steel or Steel painted
Fasteners: All external fasteners stainless steel
Installation: Recessing with mounting bracket
Weight: Refer to Type Configuration.
Entry specification
Indirect entry: M20
×
1.5 or M25
×
1.5 cable entry.
Electrical specification
Wattage: 30W/60W
Voltage: 100 - 240Vac 50/60Hz, 108 - 250Vdc
Lamp: LED Arrays
Lumen output at
emergency
25%
Emergency time
1.5h/3h
CRI: 70
Insulation class: Acc. to IEC60598
Terminals capacity: 4mm
2
Terminal/6mm
2
Terminal
Solid: 0.5~6mm
2
, Flexible: 0.25~4mm
2
5. Fields of Application
The Luminaire with Ex dem protection and IP66 sealing making it suitable
for use for potentially explosive atmospheres including ignitable gas and
dust applications.
The luminaire is designed for use in Zone1/Zone21 and Zone2/Zone22
hazardous areas in indoors and outdoors in Marine and Wet locations,
where moisture, dirt, corrosion, vibration and rough usage may be present.
Application ambient temperature is -40ºC~+55ºC or -25ºC~+55ºC . Refer to
the luminaire nameplate, For specific information, corresponding operating
temperature(T-Code).
The enclosure materials used, including any external metal parts, are High
quality materials that ensure a corrosion resistance and resistance to
chemical substances according to the requirements for use in a
“normal“ industrial atmosphere. In case of use in an extremely aggressive
atmospheres, please refer to manufacture.
6. Installation
6.1 General
The respective national regulations IEC/EN 60079-14 as well as the general
rules of engineering which apply to the installation and operation of
explosion protected apparatus will have to be observed!
The improper installation and operation may result in the explosion
protection and invalidation of the guarantee.