General Information
This publication is to be used for Eaton non-combination enclosures
designed to accept the M22 series 22mm cover control devices .
If the enclosure catalog number already has cover control devices
mounted, the existing reverse “c” shape bracket can be reused .
If the enclosure catalog number includes a blank rectangular cover,
remove it prior to installing the cover control kit (see instructions
below) .
1. Remove rectangular blank cover by pushing on the blank
cover from the back side.
2. Discard blank cover .
Cover Control Installation
3. Using the included mounting screws, mount the C600M
cover control to the base of the enclosure in the holes desig-
nated by the arrows below.
4. Terminate the wires from the M22 operators onto the starter/
contactor as illustrated in “C600M Kit Wiring Instructions“
(see page 5).
2
Instructions and Operation
P52899
Effective May 2015
Box 1 Non-Combination Enclosed Control
and C600M Cover Control Kit Wiring
EATON
www.eaton.com