Questions?/ Des questions?/ ¿Preguntas? 1-800-334-6871 [email protected]
1
Instruction Manual / Manuel d’instructions/ Instrucciones
PACKAGING CONTENTS /CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE
WARNING: FCC Regulations state that any unauthorized changes or
modifications to this equipment not expressly approved by the manufacturer
could void the user’s authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
MOUNTING AND WIRING YOUR FIXTURE
NOTE:
This fixture is intended to be conduit connected to a properly installed and properly
grounded metal weatherproof junction box (not included). All conduit connectors, conduit, and
junction boxes (sold separately) should be cULus Listed suitable for wet locations.
1.
Turn off the power at the main fuse/breaker box.
2.
Using the pattern on the box, mark and drill holes for mounting.
NOTE:
Mount this fixture in an upright and level position.
3.
Install the two bottom mounting screws (C) first, leaving enough room between the
mounting screws and the mounting surface to accommodate mounting the fixture.
4.
Screw the top mounting screw (C) into the predrilled hole and back the screw out. This
will leave the hole threaded and make installation of the fixture easier.
5.
Remove lens by loosening the two screws inside the lens. Do not remove the screws.
6.
Remove access cover (B) from fixture (A). Install
the first conduit connector and conduit (sold
separately) into the access cover (B) (Fig. 1).
7.
Feed supply wires into conduit. Attach ground wire
that is attached to fixture housing (A) to the junction
box earth ground wire.
8.
Connect the black fixture wire to the black supply
wire (hot) with UL-approved wire connector (E).
Connect the white fixture wire to the white supply
wire (neutral) with UL-approved wire connector (E).
NOTE:
Be careful to connect the wires correctly.
Make sure no bare strands of wire extend from the
wire nut or other approved wire connectors (E).
9.
Attach access cover (B) to the light fixture (A)
using the two access cover mounting screws
provided (F) (Fig. 1).
NOTE:
Make sure all wiring is placed into the arm prior to tightening the access
cover screws.
10.
Place the fixture (A) on the two lower mounting screws (C) and install the upper mounting
screw (C). Tighten all mounting screws to secure the fixture (A).
11.
Reinstall the lens, making sure to tighten the two screws to secure the lens to
the fixture (A).
12.
Connect second conduit and conduit connector at the junction box (Fig. 1).
NOTE:
This fixture can be mounted on 1-5/8 in. diameter extension arms (sold separately).
When installing fixture onto an extension arm, remove the access cover (B) and use the
included pole mounting clamp (D) and access cover mounting screws (F).
13.
Turn power back ON.
ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Adjustable wrench or ratchet wrench with 10mm socket
• Drill with 3/16 in. drill bit
• 1/2 in. diameter conduit (if applicable, length depends on application)
• 1/2 in. watertight conduit connectors (if applicable)
• Wire connectors
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• For outdoor use only.
• cULus LISTED for wet location use.
• Read and follow these instructions.
• Disconnect at fuse or circuit breaker before installing or servicing.
• Edges may cut. Handle with care.
CAUTION
• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• Upside down installation can result in overheating or accumulation of water in fixture.
Install right side up.
• This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ENGLISH
WARNING
A.
Light fixture
Appareil d’éclairage
Accesorio
B. Access cover
Cache d’accès
Cubierta de acceso
C. (3) Mounting screws
3 vis de montage
(3) Tornillos de montaje
D.
Pole mounting clamp
Patte pour montage
sur bras
Abrazadera para
montaje de poste
E. (3) Wire connectors
3 capuchons de connexion
(3) Conectores de cables
F. (2) Access cover mounting screws
2 vis de montage du cache d’accès
(2) Tornillos de la cubierta de acceso
1
Conduit
Conduit
connector
Junction
box
A
B
Gray/Gris/Gris
AL3050LPCGY
AL5550LPCIGY
Bronze/Bronze/Bronce
AL3050LPCBZ