VC 5000
5
©
Copyright Eaton Corp., 2019. All rights reserved.
flow away from the element for rapid
disengagement. By adjusting the flow, the rate of
engagement may be varied. Note that the flow
control valve does not regulate air pressure. The
supply pressure must always be adequate to
transmit the maximum required torque. Refer to the
OPERATION section of this manual for air piping
configurations.
Figure
2
2.0
INSTALLATION
⚠
WARNING
Only qualified personnel should install, adjust
or repair these units. Faulty workmanship will
result in exposure to hazardous conditions or
personal injury.
⚠
CAUTION
Do not inflate the element without having a
drum in place. Inflation of the element without a
drum in place will result in permanent damage
to the element components.
2.1
Mounting Arrangements
2.1.1
Figure 3
illustrates the gap-mounting arrangement.
In this arrangement, the element is attached to a
spider which is typically mounted on the driving
shaft. The drum is attached to a drum hub which is
typically mounted on the driven shaft. The gap
between the two shafts allows the element and
drum to be removed without disturbing either shaft.
Note
: The text in the Installation, Alignment and
Removal sections refer to this type of mounting
arrangement.