background image

1.0

INTRODUCTION

Throughout this manual there are a number 
of 

HAZARD WARNINGS

 that must be read 

and adhered to in order to prevent possible 
personal injury and/or damage to the equipment. 
Three signal words "

DANGER

", "

WARNING

", 

and "

CAUTION

" are used to indicate the 

severity of the hazard, and are preceded by the
safety alert symbol 

.

Denotes the most serious injury hazard,
and is used when serious injury or
death WILL result from misuse or 
failure to follow specific instructions.

Used when serious injury or death
MAY result from misuse or failure to
follow specific instructions.

Used when injury or product/equipment
damage may result from misuse or failure
to follow specific instructions.

It is the responsibility and the duty of all 
personnel involved in the installation, operation
and maintenance of the equipment on which this
device is used to fully understand  the

,

 

 

 

and   

  

procedures by which hazards are to be avoided.

1.1

Description

1.1.1

The Airflex

®

 RTK Triple Passage Rotorseal was

designed as a rotary connection for simultane-
ous transfer of fluids and air through three sepa-
rate passages within the same rotating shaft.

1.1.2

A mounting flange simplifies installation to the
end of the shaft and serves as a manifold for
multiple passages.

1.1.3

Three of the pipe threaded ports provide access
to the internal rotating shaft. The center port on
the cover has been specified as the air inlet.
The 1" NPT port farthest from the mounting
flange is the water outlet and the 1" NPT port
closest to the mounting flange is the water inlet.

1.1.4

Consult the factory when attempting to use the
rotorseal with mediums other than water or air,
or at excessive speeds. See Operation section
for max. speed allowable.

1.1.5

The Airflex

®

 RTK Triple Passage Rotorseal

was especially designed for use in sea water
service.

2.0

INSTALLATION

2.1

Mounting

NOTE: Rotorseal weight is 50.6 lb. [23Kg].

2.1.1

Ensure that the mounting surface is clean, flat,
and free of any nicks or burrs which may effect
proper sealing.

2.1.2

The rotorseal must be stud mounted. The use
of stainless steel fasteners is recommended.
The mounting flange is machined to accept
3/8" - 16NC3 studs. Use a threadlocking liquid
to retain the studs into the mounting plate. Use
locknuts or nuts and lockwashers to secure the
rotorseal on the studs Tighten the nuts evenly
to 28ft.-lb., using a crosswise sequence.

Ensure that exposed studs do not 
interfere with hex head screws (5) 
in the housing during operation.

2.2

Hose Connections

2.2.1

The rotorseal has three female pipe threaded
ports. The port in the center of the rotorseal
cover (3) is the air inlet. Two ports in the 
housing (1) are inlet and outlet for water. The
port closest to the cover being water outlet.
See Table 2 for port sizes.

2.2.2

The connections to the rotorseal housing must
be through flexible hoses. Hoses should be
aligned to prevent excessive loading to the 
rotorseal. All piping should be self supporting.

Rigid piping or hoses connected 
to the rotorseal will damage the 
rotorseal components.

 RS 9210 (PDF Format)

3

® Copyright Eaton Corp., 2004. All rights reserved.

 December, 2004

Содержание Airflex RTK

Страница 1: ...parts The use of non genuine Airflex replacement parts could result in substandard product performance and may void your Eaton warranty For optimum performance contact Airflex In the U S A and Canada 800 233 5890 Outside the U S A and Canada 216 281 2211 Internet www airflex com Warning Forward this manual to the person responsible for Installation Operation and Maintenance of the product describe...

Страница 2: ...Figure 1 RS 9210 PDF Format 1 Copyright Eaton Corp 2004 All rights reserved December 2004 ...

Страница 3: ...2 1 3 Cover 000424 x 0003 1 4 Split Ring 000424 x 0004 2 5 Hex Head Machine Screw 000153 x 1220 4 6 1 N P T Hex Socket Head Plug 000077 x 0022 4 7 1 8 N P T Hex Socket Head Plug 000077 x 0014 6 8 J Cup 000402 x 0078 4 9 J cup 000153 x 1227 2 RS 9210 PDF Format 2 Copyright Eaton Corp 2004 All rights reserved December 2004 ...

Страница 4: ...flange is the water outlet and the 1 NPT port closest to the mounting flange is the water inlet 1 1 4 Consult the factory when attempting to use the rotorseal with mediums other than water or air or at excessive speeds See Operation section for max speed allowable 1 1 5 The Airflex RTK Triple Passage Rotorseal was especially designed for use in sea water service 2 0 INSTALLATION 2 1 Mounting NOTE ...

Страница 5: ...ort Sizes Air Out 1 2 14 NPT Water In 1 11 1 2 NPT Water Out 1 11 1 2 NPT 3 1 3 Maximum water pressure is 75 PSIG Do not exceed maximum water pressure of 75 PSIG as it may result in water seal failure 3 2 Periodic Checks 3 2 1 On a regular basis check for leaking or damaged hoses seals Repair or replace as required 3 2 2 Excessive mis alignment of hoses or piping may cause premature component wear...

Страница 6: ...lding the rotorseal 4 2 2 All repairs should be made in a clean dust free environment 4 2 3 Pack the J Cups 8 with synthetic base grease and install into the housing bore noting the orientation of the seal See Figure 3 4 2 4 Lightly lube the O D of the rotorseal and slide the housing over the rotor 2 taking care not to damage the J Cups 4 2 5 Install new J Cups 9 onto the cover boss See Figure 4 f...

Страница 7: ...al Publication Date August 1999 Revision Date Change December 2004 Updated parts list page 2 Item 8 was 153x1226 6 0 REVISIONS RS 9210 PDF Format 6 Copyright Eaton Corp 2004 All rights reserved December 2004 ...

Страница 8: ...s Eaton shall thereupon correct any defect at its option either by repairing any defective part or parts or by making available at Eaton s plant a repaired or replacement part This warranty does not extend to normal wear parts or components of the Product such as friction material and friction surfaces LIMITATION OF WARRANTY THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES W...