13
Model 70342 and 70344
Fault - Logic
Trouble Shooting
Inspect
Servo Control
(If used)
OK
1
2
Inspect
External Control
Linkage
Defective
Repair
or
Replace
Defective
Repair
or
Replace
Symptom: Neutral Difficult or Impossible to Find
Inspect
Heat
Exchanger
OK
OK
OK
4
5
6
Check
Oil Level in
Reservoir
Fill to
Proper
Level
Defective
Below Level
Repair
or
Replace
Check
System
Pressure
Reduce
System
Load
High
OK
9
Inspect
Charge Relief
Valve
OK
11
Inspect
Charge
Pump 13
Inspect
Motor
12
Inspect
Inlet Screen
or Filter
Replace
Clogged
OK
8
Check
Charge
Pressure
10
Low
OK
OK
Replace
Pump &
Motor
Inspect
Dump Valve
(If used)
OK
7
Inspect Heat
Exchanger
By-Pass Valve
(If used)
OK
Defective
Repair
or
Replace
Defective
Repair
or
Replace
Defective
Repair
or
Replace
Defective
Repair
or
Replace
Defective
Repair
or
Replace
Symptom: System Operating Hot
Содержание 70344