ENGLISH

3. Installation

3.1 Unpacking and contents check

30

35

41

44

40

45

42

36

37

39

38

32

43

46

31

33

34

(30)

 5PX UPS

(31)

  connection cable to AC-power source  

(

5PX 2200

 and 

3000

 models only)

(32)

  2 connection cables for the protected  

equipment

(33)

 RS232 communication cable

(34)

 USB communication cable

(35)

 2 cable locking systems

(36)

 

Software

 CD-ROM

(37)

 Manual CD-ROM

(38)

 Safety instructions

(39)

 Quick start

(40)

 Mounting kit for 19-inch enclosures

Elements supplied depending on the version or 
optional
(41)

  2 supports for tower position  

(RT 2U version only)

(42)

 

FlexPDU

 module (optional)

(43)

  connection cable between 

FlexPDU

 module  

and UPS

(44)

  

NMC

 communication card (optional, standard 

on Netpack versions)

(45)

 

HotSwap MBP

 module (optional)

(46)

  connection cables between 

HotSwap MBP

 

module and UPS

Packing materials must be disposed of in compliance with all local regulations concerning waste. 

Recycling symbols are printed on the packing materials to facilitate sorting.

Содержание 5PX 1500i RT2U

Страница 1: ...PX 2200i RT2U 5PX 3000i RT2U 5PX 3000i RT3U 5PX EBM 48V RT2U 5PX EBM 72V RT2U 5PX EBM 72V RT3U Installation and user manual Copyright 2010 EATON All rights reserved Service and support Call your local...

Страница 2: ...waste center This symbol indicates that you should not discard waste electrical or electronic equipment WEEE in the trash For proper disposal contact your local recycling reuse or hazardous waste cen...

Страница 3: ...onnection with a FlexPDU Power Distribution Unit module optional 14 3 6 Connection with a HotSwap MBP module optional 14 3 7 UPS connection without a FlexPDU or HotSwap MBP module 15 4 Operation 16 4...

Страница 4: ...recycled cardboard p p Sacks and bags are made of polyethylene p p Packing materials are recyclable and bear the appropriate identification symbol p p 01 PET Materials Abbreviations Number in the sym...

Страница 5: ...1 2 x 86 2 20 6 x 17 4 x 3 4 5PX 2000i RT2U 28 50 62 80 5PX 2200i RT2U 28 50 62 80 5PX 3000i RT2U 38 08 84 00 647 x 441 2 x 86 2 25 5 x 17 4 x 3 4 5PX 3000i RT3U 37 33 82 30 497 x 441 2 x 130 7 19 6 x...

Страница 6: ...al battery modules 7 16 A outlet for connection of equipment Primary group 8 Two groups of 2 programmable outlets for connection of equipment Group 1 and 2 9 Groups of 4 outlets for connection of equi...

Страница 7: ...yellow Alarm Indicator red Normal mode 100 17min 1EBM 100 2 7kW 3kVA Efficiency 98 Escape Up Down Enter On Off button The following table shows the indicator status and description Indicator Status D...

Страница 8: ...essed Normal mode The UPS is operating normally The UPS is powering and protecting the equipment In AVR mode Load protected LED is ON No beep The UPS is operating normally but the utility voltage is o...

Страница 9: ...address 2 6 User settings The following table displays the options that can be changed by the user Description Available settings Default settings Local settings Language English Fran ais Deutsch Ital...

Страница 10: ...detected on the output Disable Sleep mode Disable Enable If disable LCD and communication will turn OFF immediately after UPS is OFF If enable LCD and communication stays ON 1h30 min after UPS is OFF...

Страница 11: ...Safety instructions 39 Quick start 40 Mounting kit for 19 inch enclosures Elements supplied depending on the version or optional 41 2 supports for tower position RT 2U version only 42 FlexPDU module...

Страница 12: ...in tower position Note The two supports for the tower position are used on the RT 2U version only 3 3 Installation in rack position Follow steps 1 to 4 for module mounting on the rails 1 1 3 4 4 3 2...

Страница 13: ...tion cards optional standard on the Netpack versions It is not necessary to shutdown the UPS before installing a communication card 1 Remove the slot cover 4 secured by screws 2 Insert the communicati...

Страница 14: ...with a HotSwap MBP module optional The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads HotSwap function 5PX HotSwap MBP 46 51 52 55 54 53...

Страница 15: ...ce and the true electrical consumption of the total load 10 32 35 9 7 31 8 1 5PX 1500i 2000i connect the UPS input socket 10 to the AC power source using the cable of the protected equipment 5PX 2200i...

Страница 16: ...Cold start setting in ON OFF Settings on page 10 To start the UPS on battery 1 Press the button on the UPS front panel until the UPS front panel display illuminates and shows a status of UPS starting...

Страница 17: ...shut down the UPS These functions are obtained by opening a contact connected between the appropriate pins of connector 5 on the rear panel of the UPS see figures below 5 Remote control connection and...

Страница 18: ...the equipment anymore Note the alarm message and the UPS Serial Number then contact your service representative Troubleshooting a UPS equipped with the HotSwap MBP module Indication Diagnostic Correct...

Страница 19: ...elets and all other metal objects from the hands and arms p p use tools with an insulated handle p p Battery tray removal E D C A B A Remove the middle part B Remove the left hand side of the front pa...

Страница 20: ...o Bypass position The red LED on the HotSwap MBP module goes ON indicating that the load is supplied directly with AC input source power 2 Stop the UPS by pressing the button on the UPS control panel...

Страница 21: ...mperature range l Storage temperature range l Relative humidity l Noise level 0 to 40 C 15 to 50 C 20 to 90 without condensation 45 dBA 50 dBA 1 The high and low thresholds can be adjusted using UPS s...

Страница 22: ...connected to the UPS output Low battery warning This is a battery voltage level indicating that battery power is low and that the user must take action in light of the imminent break in the supply of...

Отзывы: