1. Introduction

Thank you for selecting an EATON product to protect your electrical equipment. 

 

The 5P range has been designed with the utmost care.
We recommend that you take the time to read this manual to take full advantage of the many features  

of your UPS (Uninterruptible Power System). 

 

Before installing 5P, please read the booklet presenting the safety instructions.  

Then follow the instructions in this manual. 

 

To discover the entire range of EATON products and the options available for the 5P range,  

we invite you to visit our web site at www.eaton.com/powerquality or contact your EATON representative.

1.1 Environmental protection

EATON has implemented an environmental-protection policy.
Products are developed according to an eco-design approach.

Substances

This product does not contain CFCs, HCFCs or asbestos.

Packing

To improve waste treatment and facilitate recycling, separate the various packing components.
•  The cardboard we use comprises over 50 % of recycled cardboard.
•  Sacks and bags are made of polyethylene.
•  Packing materials are recyclable and bear the appropriate identification symbol 

01

PET

Materials

Abbreviations

Number in  
the symbols 

Polyethylene terephthalat

PET

01

High-density polyethylene

HDPE

02

Polyvinyl chloride

PVC

03

Low-density polyethylene

LDPE

04

Polypropylene

PP

05

Polystyrene

PS

06

Follow all local regulations for the disposal of packing materials.

End of life

EATON will process products at the end of their service life in compliance with local regulations.
EATON works with companies in charge of collecting and eliminating our products at the end of  

their service life.

Product

The product is made up of recyclable materials.
Dismantling and destruction must take place in compliance with all local regulations concerning waste.
At the end of its service life, the product must be transported to a processing centre for electrical and  

electronic waste.

Battery

The product contains lead-acid batteries that must be processed according to applicable local regulations 

concerning batteries. 
The battery may be removed to comply with regulations and in view of correct disposal.

01

PET

Содержание 5P 650 AU

Страница 1: ...5P 650 AU 5P 650i R 5P 850 AU 5P 850i R 5P 1150 AU 5P 1150i R 5P 1550 AU 5P 1550i R User s guide ...

Страница 2: ......

Страница 3: ...rights reserved Service and support Call your local service representative 620 00082 01 au en Tower models 5P 650 AU 5P 850 AU 5P 1150 AU 5P 1550 AU 1U Rack models 5P 650i R 5P 850i R 5P 1150i R 5P 1550i R Installation and user manual ...

Страница 4: ... waste center This symbol indicates that you should not discard waste electrical or electronic equipment WEEE in the trash For proper disposal contact your local recycling reuse or hazardous waste center Information advice help UPS directives Safety IEC 62040 1 2008 C2 EMC IEC 62040 2 2005 VCCI Performance IEC 62040 3 2010 CE mark EN 62040 1 2008 and EN 62040 2 2006 C1 Class B emission level CISPR...

Страница 5: ...s 13 3 3 Wall installation of rack models 13 3 Installation 14 3 4 Installation of rack models 650i R only 14 3 5 Installation of rack models 850i R 1150i R 1550i R 14 3 Installation 15 3 5 Communication ports 15 4 Operation 16 4 1 Start up and Normal operation 16 4 2 Starting the UPS on Battery 16 4 3 UPS Shutdown 16 4 4 Operation on Battery Power 16 4 5 Return of AC Input Power 17 4 6 UPS remote...

Страница 6: ...ses over 50 of recycled cardboard Sacks and bags are made of polyethylene Packing materials are recyclable and bear the appropriate identification symbol 01 PET Materials Abbreviations Number in the symbols Polyethylene terephthalat PET 01 High density polyethylene HDPE 02 Polyvinyl chloride PVC 03 Low density polyethylene LDPE 04 Polypropylene PP 05 Polystyrene PS 06 Follow all local regulations ...

Страница 7: ... x 5 9 345 x 233 x 150 5P 1150AU 24 10 10 91 13 6 x 9 2 x 5 9 345 x 233 x 150 5P 1550AU 35 20 15 95 17 5 x 9 2 x 5 9 445 x 233 x 150 Rack models H W D Description Weights lb kg Dimensions inch mm D x W x H 5P 650i R 19 00 8 6 14 3 x 17 2 x 1 7 363 5 x 438 x 43 2 5P 850i R 30 40 13 8 20 0 x 17 2 x 1 7 509 x 438 x 43 2 5P 1150i R 32 70 14 64 20 0 x 17 2 x 1 7 509 x 438 x 43 2 5P 1550i R 42 70 19 36 ...

Страница 8: ...mmunication port 3 Slot for optional communication card 4 Connector for ROO remote ON OFF or RPO Remote Power Off control 5 Outlets for connection of critical equipment Primary group 6a Group 1 programmable outlets for connection of equipment 6b Group 2 programmable outlets for connection of equipment 7 Attached 1 8 m input power cord for AC power source 3 PIN AUS 8 Ground screw ...

Страница 9: ...nication port 2 RS232 communication port 3 Slot for optional communication card 4 Connector for ROO remote ON OFF or RPO Remote Power Off control 5 Outlets for connection of critical equipment Primary group 6a Group 1 programmable outlets for connection of equipment 6b Group 2 programmable outlets for connection of equipment 7 Socket for connection to AC power source 8 Ground screw ...

Страница 10: ... 100 720W 800VA Efficiency 98 Escape Up Down Enter On Off button Rack models Normal mode 100 10min 100 720 W 800VA Efficiency 98 Alarm Indicator red On battery Indicator yellow Power On Indicator green On Off button Up Down Enter Escape The following table shows the indicator status and description Indicator Status Description Green On The UPS is operating normally Yellow On The UPS is on battery ...

Страница 11: ...r Equipment is not powered until button is not pressed Normal mode The UPS is operating normally The UPS is powering and protecting the equipment In AVR mode No beep The UPS is operating normally but the utility voltage is outside normal mode thresholds The UPS is powering the equipment through a Automatic Voltage Regulation device The equipment is still normally protected On Battery Battery LED i...

Страница 12: ...2 7 User settings The following table displays the options that can be changed by the user Description Available settings Default settings Local settings Language English Français Deutsch Italiano Português Español Русский Menus status notices and alarms UPS fault Event Log data and settings are in all supported languages English User selectable when UPS is powered for the first time LCD settings ...

Страница 13: ...able Energy saving Disable Enable If enabled UPS will shutdown after 5min of back up time if no load is detected on the output Disable Sleep mode Disable Enable If disabled LCD and communica tion will turn OFF immediately after UPS is OFF If enabled LCD and communication stays ON 1h30 min after UPS is OFF Disable Remote command Disable Enable If enabled shutdown or restart commands from software a...

Страница 14: ...e CDROM 4 2 connection cables for the protected equipment 5 RS232 communication cable 6 USB communication cable 7 Cable locking systems 1 x 4 outlets 650i R and 850i R models 1 x 6 outlets 1150i R and 1550i R models 8 1U Rack kit ears only for 650i R model Packing materials must be disposed of in compliance with all local regulations concerning waste Recycling symbols are printed on the packing ma...

Страница 15: ...Page 13 620 00082 01 au en ENGLISH 3 Installation 3 2 Installation of tower models 3 3 Wall installation of rack models 1 1 2 2 ...

Страница 16: ...els 850i R 1150i R 1550i R Follow steps 1 to 4 for module mounting on the rails 3 Installation The rails and necessary hardware are supplied by EATON 1 1 2 2 3 3 4 4 3 4 Installation of rack models 650i R only Follow steps 1 to 3 for rack mounting 2 3 2 3 1 ...

Страница 17: ...Installation of the communication cards optional 3 It is not necessary to shutdown the UPS before installing a communication card 1 Remove the slot cover 3 secured by screws 2 Insert the communication card in the slot 3 Secure the card cover with the 2 screws Characteristics of the optocouplers communication port optional Pins 1 3 4 5 6 10 not used Pin 2 common user Pin 7 low battery Pin 8 operati...

Страница 18: ... See the Cold start setting in ON OFF Settings on page 11 To start the UPS on battery 1 Press the button on the UPS front panel until the UPS front panel display illuminates and shows a status of UPS starting The UPS cycles through Standby mode to Battery mode The indicator illuminates solid The UPS supplies power to your equipment 2 Check the UPS front panel display for active alarms or notices b...

Страница 19: ...e UPS These functions are obtained by opening a contact connected between the appropriate pins of connector 4 on the rear panel of the UPS see figures below 4 Remote control connection and test 1 Check that the UPS is OFF and disconnected from the AC input source 2 Remove connector 4 after unscrewing the screws 3 Connect a normally closed volt free contact 60 V DC 30 V AC max 20 mA max 0 75 mm2 ca...

Страница 20: ...emove some of the equipment from the UPS The UPS continues to operate but may shutdown if the load increases The alarm resets when the condition becomes inactive End of battery life The end of the battery life is reached Contact your service representative for battery replacement Event An UPS event occurs Example Remote Power OFF the RPO contact has been activated to shutdown the UPS and now preve...

Страница 21: ...y removal on tower models This operation must be performed when the UPS is switched OFF A A Remove the front panel B B Disconnect the battery block by separating the two connectors never pull on the wires C C Remove the plastic protection cover in front of the battery one screw D D Pull the plastic tab to remove the battery block and replace it Mounting the new battery module Carry out the above i...

Страница 22: ...he battery block by separating the two connectors never pull on the wires D D Remove the metal protection cover in front of the battery two screws E E Pull the plastic tab to remove the battery block and replace it Mounting the new battery module Carry out the above instructions in reverse order To ensure safety and high performance use only batteries supplied by EATON Take care to firmly press to...

Страница 23: ...d Tower 1 x 12 V 9 Ah 2 x 12 V 7 Ah 2 x 12 V 9 Ah 3 x 12 V 9 Ah Rack 2 x 6 V 9 Ah 4 x 6 V 7 Ah 4 x 6 V 9 Ah 6 x 6 V 9 Ah Environment Operating temperature range Storage temperature range Relative humidity Noise level 0 to 35 C 0 to 40 C 15 to 50 C 0 to 90 without condensation 40 dBA 1 The high and low thresholds can be adjusted using UPS settings up to 150 294 V 2 Up to 40 Hz in low sensitivity mo...

Страница 24: ... low and that the user must take action in light of the imminent break in the supply of power to the load Normal AC input The AC power line supplying the UPS under normal conditions Percent load Ratio of the power effectively drawn by the load to the maximum output of the UPS Personalisation It is possible to modify certain UPS parameters set in the factory Certain UPS functions can also be modifi...

Страница 25: ......

Страница 26: ...www eaton com Powerquality EATON 5P 620 00082 01 au ...

Отзывы: