A. Ex Annexe

Special Conditions of certification 

(a) Specific Conditions for Safe Use. 

1. No modifications must be made to the flamepaths of the unit without consultation of the
drawings listed on the schedule.
2. Temperatures could exceed 70°C at the cable gland or 80°C at the branching point, suitably
rated cable must be selected.
3. Use only hex socket head fasteners with property class of A4-70 for securing end covers &
shafts to housings.
4. When fitted, the optical fibre output from the camera must always be terminated within a
suitably certified enclosures or safe area..
5. Only armoured cable or conduit is to be utilized when fitted with a fibre optic output in order
to protect the fibre optic cable.
6. Precautions must be taken to avoid dust from forming layers on the equipment.
7. Antennas used with the equipment shall be passive with nominal impedance of 50Ω and have a
minimum degree of protection IP6X. If the antenna utilizes a wire conductor the minimum
diameter shall be 0.1mm. Alternatively if a track antenna is used, the tracking shall have a
minimum width of 0.4mm
8. The antenna circuit does not meet the dielectric strength requirements of Clause 6.3.13. Refer
to manufacturers’ instruction manual for further details.

Labelling Details. 

 II 2 G Exdb II* T6-3*Gb -##°C ≤ Ta ≤ +##°C 
II 2 D Ex tb III* T135°C Db   IP66/67 
II 2 G Exdb op is II*  T4/3 Gb -##°C ≤ Ta ≤ +##°C 

(Illuminator) 

II 2 D Ex tb op is III*  T135°C Db   IP66/67 
II 2 G Exdb op pr II*  T6…3*Gb -##°C ≤ Ta ≤ +##°C 

(Fibre Optic) 

II 2 D Ex tb op pr III*  T135°C Db   IP66/67 
II 2 G Ex db ????[Ex ia Ga] IIC T6…T5 Gb -##°C ≤ Ta ≤ +##°C 

(Wireless IS) 

II 2 D Ex tb ????[Ex ia Ga] IIIC T135°C Db   IP66/67 

Note: T class, Gas Group and ambient temperature, is dependent on the assembly configuration 
and maximum internal power dissipation.  
???? = Optional op pr/op is coding 
*=T class, Gas Group 
## = Ambient Temperature range 

Marked Ambient range can be any of the

      

-40

C to +40

C, -60

C to +40

C, -40°C to +50°C ,  

following

  

-40°C to +55°C , -40

C to +70

C, -60

C to +70

C  

Wireless Ex ia 

T6:  -40°C ≤ Tamb ≤ +40°C  
T5:  -40°C ≤ Tamb ≤ +50°C or 
T5:  -40°C ≤ Tamb ≤ +55°C 

Содержание 2400 Series

Страница 1: ...eg BS EN 60079 14 2014 Explosive atmospheres Part 14 Electrical installations design selection and erection IEC 60079 14 2013 IECEx ATEX Certified II 2 G Ex db IIC II 2 D Ex tb IIIC Whilst every effo...

Страница 2: ...ue 2 0 09 03 2016 Inclusion of Annexes 3 0 05 04 2016 Inclusion of Ex ia removal of ratings page 5 Additions to annexe E 4 0 06 04 2016 Change in Harmonised standard issues 5 0 01 09 2016 Change Cert...

Страница 3: ...on 11 3 3 2 Washer Nozzle Installation 12 3 4 Electrical Installation 13 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 13 3 4 2 XP XT Common Connection Examples 14 3 4 3 Ele...

Страница 4: ...II of ATEX Directive 2014 34 EU 7 Be aware that aggressive substances may require extra protection of the equipment to maintain its integrity and explosion protection 8 The equipment may need additio...

Страница 5: ...indow is made with toughened glass or in the case of the Thermal Imager and Dual Imager versions is made from Infra red transparent material and which is factory fitted with a mechanical window guard...

Страница 6: ...iled connection and configuration of units the installer should refer to individual project specific drawings and information In addition to this manual there are various addendums available that cove...

Страница 7: ...weight of the complete unit Do not stand or place objects directly under installed system Due care must be taken to ensure sufficient clearance is allowed to permit full rotation of the unit with its...

Страница 8: ...EATON Installation Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 8 of 21 Fig 1 XP26VW Example XP Series unit showing base mount fixing points Fig 2 BPW6800 Wall Bracket...

Страница 9: ...tion Maintenance Instructions IMI 70 XF XC XP XT Issue 7 2016 Eaton Page 9 of 21 Fig 3 XC40VW Example XC Series unit showing shaft mount fixing points Fig 5 BFP0600 900 1200 Column Spacer Fig 4 BFW500...

Страница 10: ...e a mounting plate on the bottom of the housing tube that have four 4 No M6 Threaded fixing points Fig 6 The type and size of these fixings to be supplied by the user installer and must be suitable fo...

Страница 11: ...ved prior to installation The correct sunshield fixings for each model are supplied with the camera system and should be positioned as detailed below To mount the sunshields first they must be positio...

Страница 12: ...ble washer nozzle and mounting bracket These should be fitted during installation with the supplied fixing and positioned to allow cleaning fluid to reach the camera housing window when the wash comma...

Страница 13: ...Voltage 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 1 Always use colour coded conductors or other identification of conductors for ease of wiring and identification of fu...

Страница 14: ...DATA A DATA B 230VAC L VIDEO SCREEN VIDEO SIGNAL 110VAC N DATA A DATA B 110VAC L VIDEO SCREEN VIDEO SIGNAL 24VAC N DATA A DATA B 24VAC L VIDEO SCREEN VIDEO SIGNAL 230VAC MODEL WITH NO PUMP OUTPUT 110V...

Страница 15: ...se order for as built wiring and connection details of the unit Warning This cover must not under any circumstances be removed until at least 5 minutes after the disconnection of power source To gain...

Страница 16: ...AC PUMP SUPPLY N 24VAC PUMP SUPPLY VIDEO DIRECT TO CAMERA 24VAC MODEL WITH PUMP OUTPUT J1 TH HEATER 22 O 10W HEATER 22 O 10W J3 J2 24VAC N DATA A DATA B 24VAC L NC EARTH SWITCH L 24VAC PUMP SUPPLY N 2...

Страница 17: ...sher nozzle Check and if necessary replace the window wiper blade assembly Please read and be familiar with the instructions before servicing the Pan Tilt or housing 4 1 Corrosion Protection Although...

Страница 18: ...nyl and affixed product The contents of the label will be in ENGLISH The label shows A Name of Manufacturer B Model Type and reference C Operating Voltage D EX ratings E ATEX Certificate IECEX certifi...

Страница 19: ...4 x M10 fixings on 182mm pcd Standalone housing Depending on mounting brackets Supply voltage 24VAC 50 60Hz or 100 to 230VAC with integral transformer Power consumption Max 120 Watts depending on mod...

Страница 20: ...impedance of 50 and have a minimum degree of protection IP6X If the antenna utilizes a wire conductor the minimum diameter shall be 0 1mm Alternatively if a track antenna is used the tracking shall ha...

Страница 21: ...indow assemblies integrity of the welded construction shall also be verified during routine overpressure testing Empty enclosures may be tested The individual parts of a flameproof enclosure for examp...

Отзывы: